MODELING OF MERIDIAN CHANNELS

Zimin Wang, Yonghong Tan, Miyong Su

2009

Abstract

In this paper, the auto-regressive and moving average (ARMA) models are constructed for the meridian channels based on the measuring data obtained from the acupoints in the Lung Channel of Hand-Taiyin (LU), the Pericardium Channel of Hand-Jueyin (PC). For comparison, the ARMA models for the contrastive nonacupoints around the measured acupoints are also obtained. Then, the analysis based on the zeros-poles distribution of the obtained models is implemented.

References

  1. Akaike, H. (1969). Fitting autoregressive models for prediction. In Annals of the Institute of Statistical Mathematics.
  2. F. III John, Trentini, B. T. and Erlichman, J. S. (2005). The antinociceptive effect of acupressure in rats. In The American Journal of Chinese Medicine. World Scientific Publishing Company.
  3. GEP Box, G. J. and Reinsel, G. (1994). Time Series Analysis: Forecasting and Control. Prentice-Hall, Englewood Cliffs, New Jersey.
  4. Hwang, H. (2001). Insights into neural-network forecasting time series corresponding to arma (p,q) structures. In Omega 29.
  5. I. Rojasa, O. Valenzuelab, F. R. A. G. L. H. H. P. L. and M.Pasadasb (2007). Soft-computing techniques and arma model for time series prediction. In Neurocomputing.
  6. J. Julia, M. T. and FACOG (1998). A modern interpretation of acupuncture and the meridian system. In 2nd International Conference on Bioelectromagnetism.
  7. Korosec, D. (2000). Parametric estimation of the continuous non-stationary spectrum and its dynamics in surface emg studies. In International Journal of Medical Informatics.
  8. W.Zhang, R. X. and Zhu, Z. (1999). The influence of acupuncture on the impedance measured by four electrodes on meridians. In Acupunct and Electro-Therap Res. Int.J.
  9. Yang, H. (1997). The research and application of the dynamic testing system for point skin resistance. In Journal of Biomedical Engineering.
Download


Paper Citation


in Harvard Style

Wang Z., Tan Y. and Su M. (2009). MODELING OF MERIDIAN CHANNELS . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 167-172. DOI: 10.5220/0001433001670172


in Bibtex Style

@conference{biodevices09,
author={Zimin Wang and Yonghong Tan and Miyong Su},
title={MODELING OF MERIDIAN CHANNELS},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={167-172},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001433001670172},
isbn={978-989-8111- 64-7},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - MODELING OF MERIDIAN CHANNELS
SN - 978-989-8111- 64-7
AU - Wang Z.
AU - Tan Y.
AU - Su M.
PY - 2009
SP - 167
EP - 172
DO - 10.5220/0001433001670172