AN OVERVIEW OF PLC NETWORK PERFORMANCE IN
PRESENCE OF HOUSEHOLDS INTERFERENCE
Haroldo Zattar, Jakson Bonaldo
Department of Electrical Engineering, Federal University of Mato Grosso, Cuiabá, Brazil
Gilberto Carrijo
Department of Electrical Engineering, Federal University of Uberlandia, Uberlândia, Brazil
Keywords: Power line communication, PLC network, impulsive noise at PLC network, PLC performance.
Abstract: This paper presents an overview of PLC. In addition the paper shows the performance of a PLC using an
experimental LAN network in presence of different types of noise caused by households. This paper also
presents the experimental results to find the best TCP window size to be used in a PLC network. The
performance investigation was accomplished in the Telecommunication laboratory of Federal University of
Mato Grosso, Brazil.
1 INTRODUCTION
Power Line Communication (PLC) is growing
interest in the prospect of reusing in building power
line cables to provide a broadband LAN within the
home or office. The major advantage offered by
power line based home networks is the availability
of an existing infrastructure of wires and wall
outlets. The use of this medium for communications
at higher frequencies presents some technical
challenging problems (Ferreira and Grové, 1996)
(Philipps, 1998) as interference. Electric appliances
with brush motors, switching power supplies and
halogen lamps are examples that produce impulsive
noise that can reduce the reliability of
communication signals (Gotz , Rapp, and Dostert,
2004) (Sutterlin and Downey). The objective of this
paper is to present the performance of PLC network
and evaluate it with different households’
interferences.
2 AN OVERVIEW OF PLC
PLC is a set of equipment, software and
management services that when overlaid on the
electric grid provides users with communication
means over existing power lines (cables
transmitting electricity) (Paulidov and Han Vink,
2002).
In Brazil we have only 14,49% of houses with
computers that access internet. Half of this value
uses broadband internet. Therefore PLC will have
many opportunities to offer broadband to homes and
small offices. On the other hand, power lines have
many problems to overcome. Noise in power lines is
a significant problem for data transmission (Ma and
So, 2005). This is because it rarely has similar
properties to the easily analyzed white Gaussian
noise of the receiver front ends.
Typical sources of noise are brush motors,
fluorescent and halogen lamps, switching power
supplies and dimmer switches. The noise in power
lines can be impulsive or frequency selective in
nature and, sometimes, both. The noise in power
lines can be classified into four categories (Hrasnica
and Haidine, 2004): Colored noise, narrowband
background noise, periodic impulsive noise and
impulsive noise.
Due to the above mentioned power line channel
characteristics, it is necessary to carefully select
modulation schemes and sophisticated error
correction and detection technologies for forming up
reliable physical layers as a basis for robust PLC. In
this paper the PLC equipments work with multi
carrier modulation in the form of orthogonal
frequency division multiplexing (OFDM)
230
Zattar H., Bonaldo J. and Carrijo G. (2008).
AN OVERVIEW OF PLC NETWORK PERFORMANCE IN PRESENCE OF HOUSEHOLDS INTERFERENCE.
In Proceedings of the Tenth International Conference on Enterprise Information Systems - SAIC, pages 230-233
DOI: 10.5220/0001690502300233
Copyright
c
SciTePress
(Sugimoto, 2002) (Langton, 2004) (Pinto and
Albuquerque, 2002).
3 PLC NETWORK ELEMENTS
PLC network uses the electrical supply grids as a
medium for the transmission of different kinds of
information and the realization of various
communications and automation services. The basic
network elements are PLC adapter, PLC base/master
station and filter.
4 THE PLC ADAPTERS
CHARACTERISTICS
In this paper the adapter used was an AV200 power
line Ethernet adapter and a filter. Both from
Corinex. This Ethernet adapter supports distribution
of video, voice and broadband internet access over
premise existing electrical wires. The AV200 PLC
Corinex features are (AV 200, 2007):
10/100 Base T Fast Ethernet interface;
Physical data rate in the power line up to 200
Mbps with distances up to 300 m;
OFDM technology and powerful error
correction system
Frequency operation from 13.3 to 33.3 MHz.
MAC filtering can discard Ethernet frames if
they come from source MAC address which is
not present in a list of allowed MAC
addresses.
Integrated 802.1 Q VLAN.
5 PLC NETWORK
CONFIGURATIONS
In order to investigate the PLC network
performance, this paper uses a simple LAN
network configuration illustrated in figure 1. The
filter was used in PLC network to isolate this
network from noise, or traffic, from the rest of the
electrical grid.
A test was accomplished to verify the performance
results using a configuration showed in the figure 2.
It was used to verify and certify that the filter really
isolates the electrical noise produced by household
appliance. Two analyzers were used simultaneously
to guarantee that the result during the FTP process
was almost the same.
6 EXPERIMENTAL RESULTS
In this paper were investigated the PLC performance
in a best condition and normal condition and in the
presence of households interference. It was also
accomplished an evaluation related to the efficiency
result considering the increase of the TCP window
size. All parts of the tests were run five times and
the average result will be showed in this paper.
Figure 1: Simple network configuration.
Figure 2: PLC network configuration with an electrical
appliance noise over a PLC filter.
AN OVERVIEW OF PLC NETWORK PERFORMANCE IN PRESENCE OF HOUSEHOLDS INTERFERENCE
231
6.1 PLC Performance Considering the
Best Condition
The first experimental tests were used to verify the
performance of the PLC network using the network
configuration of the figure 1 without electrical noise
appliance and using an appropriate filter. The result
is shown in figure 3.
Figure 3: Throughput result of PLC network without noise
presence and using a noise filter.
Analyzing the graph it is possible to note that
the average throughput was 92.36 Mbps and the
maximum throughput obtained was 96.73 Mbps.
Therefore the efficiency result is 92.36%. The
PLC channel bandwidth is 100 Mb because it is
limited by 10/100 Base T Fast Ethernet interface
that interconnects the PLC adapter with the
computer. In the computer it was used GB
Ethernet board. In this condition the efficiency is
almost the same of using an Ethernet LAN. The
reason is that the noise filter is really able to
avoid external interference provided by
households.
After this, it was used some electric household
as mixer, TV, ventilator, blender, electric razor,
hairdryer, dimmer, halogen lamp and switch
power supply to generate noise on the PLC
network and to evaluate the result performance.
The throughput result is showed in figure 4. It was
used the network configuration of figure 1. The
analysis made with halogen lamp and mixer
showed that they also affect the performance of
the PLC LAN network.
Analyzing the graph, it is possible to verify
that the use of TV with ventilator together
operating in the LAN network offer very low
noise and therefore the efficiency reached was
almost near the best condition obtained. While the
best condition efficiency is 92.36%, the result
with the presence of TV and ventilator reached
90.6% of efficiency. Then the conclusion is that
these two households produce low noise that does
not damage the computers during data transfer
using a PLC network.
On the other hand, the others electric equipments
affect directly the PLC network efficiency.
This happens because these households produce
impulsive noise that is very damaging to PLC
networks. The worst results were obtained using
switch power supply. The efficiency result was less
than 1%. Therefore the use of noise filter is
necessary to protect the network communication
avoiding a drastic reduction of the PLC LAN
network efficiency.
Comparison of the electric appliance noise over PLC LAN network
0
10
20
30
40
50
60
70
80
90
100
012345678910
Time (min)
Efficiency (%
)
ideal situation dry hair blender
dimmer mixer electric razor
TV and ventilator halogen lamp switching power supply
Figure 4: Efficiency result of PLC network considering a
noise presence from electrics appliances.
The efficiency reached by them was less than
30%. Then it is important to use a noise filter for
each halogen lamp and for the use of mixer. When a
dimmer and electric razor was tested the efficiency
result was less than 40%. Finally it was tested a
hairdryer and a blender which the efficiency result
was near of 50%.
These results prove that when there is an
incidence of noise it is necessary to use an
appropriate filter to avoid low efficiency in a PLC
network. The Corinex noise filter tested really
solved the interference caused by the analyzed
households. Therefore PLC network is indicated to
be used at residences and small offices with
excellent performance.
6.2 PLC LAN Network Evaluation
Related to the Increase of the TCP
Window Size
One of the main factors for the TCP/IP architecture
over PLC networks to become attractive is to make
the available bandwidth in the link capable to be
ICEIS 2008 - International Conference on Enterprise Information Systems
232
large used during data transmission. To make this
happen it is possible to increase the initial
congestion window (Paduri, 1998) (Zattar, 2007).
The figure 5 shows the throughput results for each
TCP window size.
Throughput x window size
0
10
20
30
40
50
60
70
80
90
100
1248163264128256512104820964192
window size (KB)
Throughput (Mbps)
Figure 5: Results from PLC LAN network related to the
increase of the TCP Window size.
Taking a look at figure 5 it is possible to note
that with the increase of the TCP window size, the
throughput results grow. The maximum efficiency is
reached with TCP window size of 512 KB. For this
situation the efficiency result was upper than 90%.
For the TCP window size upper than 512 KB, the
PLC LAN efficiency become lower.
6.3 PLC Performance in a LAN
without Noise Filter
It was accomplished the analysis of the PLC
considering a LAN without noise filter as showed at
figure 1 without using a noise filter.
The results obtained are presented in figure 6. The
TCP window size was 512 KB. Observing the graph
of the figure 6 the throughput average was 86.44
Mbps and the maximum throughput reached was
96.76 Mbps.
Figure 6: Throughput result of PLC network without an
appropriate filter.
7 CONCLUSIONS
This paper showed the analysis performance of PLC
network considering a best condition for a LAN.
Another analysis was made evaluating the efficiency
result considering the interference presence by some
households. The worst efficiency was obtained when
it was used a switch power supply. The results
obtained considering the increase of TCP window
size showed that 512 KB is the most adequate size
for the PLC LAN network. For an operating of a
PLC LAN network it is fact that the noise filter is
necessary to reach high efficiency result.
REFERENCES
Ferreira, HC., Grové, H. M., 1996. Power Line
Communicatios: An Overview. IEEE.
Philipps, H., 1998. Performance Measurements of Power
Line Channels at High Frequencies, International
Symposium on Power Line Communications and its
Applications.
Gotz, M., Rapp, M., Dostert, K., 2004. Power Line
Channel Characteristics and their Effect on
Communication System Design, IEEE
Communication Magazine, vol 42, pp. 78-86.
Sutterlin, P., Downey, W., A Power Line Communication
Tutorial – Challenges and Technologies, Echelon
Corporation, USA.
Sugimoto, K., 2002. Performance Improvement of OFDM
System with Consideration on the Characteristics of
Power line Noise, IEICE Trans Fundamentals, vol
E85-A.
Paulidov, N., Han Vinck, A. J., 2002. Power Line
Communications: State of the Art and Future Trends.
IEEE Communications Magazine.
Lin, Y., Haniph A., 2002. A Comparative Performance
Study of Wireless and Power Line Networks.
Department University of Florida.
Ma., Y. H., SO, P. L., 2005. Performance Analysis of
OFDM Systems for Broadband Power Line
Communications under Impulsive Noise and
Multipath Effects. IEEE Transaction on Power
Delivery. vol 20.
Hrasnica, H., Haidine, A., Lehnert, R., 2004. Broadband
Power Line Communications Network, John Wiley &
Sons.
AV 200 Power Line Ethernet Adapter. User Guide.
available at www.corinex.com.
Agilent Analyzer Fast Ethernet Network. available at
www.agilent.com
COMMTRAFFIC version 3.1 (Evaluation Version).
available at www.tamos.com.
Poduri, K., 1998. Simulation Studies of Increased Initial
TCP Window Size, RFC 2415.
Zattar, H., 2007. An Evaluate and Comparison of TCP
Congestion Avoidance Algorithms. IEEE GIIS 2007.
AN OVERVIEW OF PLC NETWORK PERFORMANCE IN PRESENCE OF HOUSEHOLDS INTERFERENCE
233