SYNTHESIS OF DRIVING SIGNALS FOR MEDICAL IMAGING ANNULAR ARRAYS FROM ULTRASONIC X-WAVE SOLUTIONS

l. Castellanos, A. Ramos, H. Calás

2010

Abstract

An interesting approach for achieving high-resolution in ultrasonic imaging, is producing in real time limited diffraction waves with annular arrays; this potential option was presented by J.-Y. Lu in 1991 for collimating ultrasonic beams in medical imaging, approximating classical X waves with a finite aperture 10-annuli array, driven with 0-order X-wave excitation signal generated by solving the isotropic/homogeneous scalar wave equation. However, detailed solutions for a proper array electrical driving in order to form X-wave fields of both pressure and velocity potential have been not still reported. Paper objective is to show a tool to obtain approximated solutions for the inverse problems (aspect by-passed in classical approach) of synthesizing voltage excitations sets for producing both possible X wave field profiles, and comparatively investigate their distinct beam collimating capacities. All calculations, simulations and analyses were made for an ad-hoc developed 8-rings 2.5 MHz array transducer. Results show field distributions in ultrasonic pressure, created for two driving approaches derived by our inverse processing from calculated pressure and velocity potential fields. The good performances resulting in both cases for beam collimation, confirm the tool applicability. Results suggest the viability of our procedure as a promising alternative to classical X-wave driving calculations.

References

  1. Arnau, A., “Piezoelectric Transducer and Aplications”, Edit. Springer, ISBN 3-540-20998-0, 2004.
  2. Crespo., Y., Calas H., Moreno E., Eiras J. A., Secada J. D., Leija L., “New X-wave solutions of isotropic/homogenous scalar wave equation”, ICEEE and CIE, IEEE Catalog Number: 05EX1097, ISBN: 0- 7803-9230-2, p. 164-167, 2005.
  3. Donnelly, R., Ziolkowski R., “A method for constructing solutions of homogeneous partial differential equations: localized waves”, Proc. R. Soc. Lond. A., No. 437, p. 673-692, 1992.
  4. Lu, J. Y., Greenleaf, J. F., “Theory and Acoustic Experiments of Nondiffracting X Waves”, IEEE Ultrason. Symp. Proc., p. 1155, 1991.
  5. Mason, W. P., “Physical Acoustics, Volume I-Part A”, Edit. Academic Press, 1964.
  6. Püttmer, A., Hauptmannm P., Lucklum, R., Krause, O., Henning B., “SPICE model for lossy piezoceramic transducer”, IEEE Trans. Ultrason. Ferroelec. Freq. Contr., Vol. 44, No. 1, p. 60-66, 1997.
  7. Stepanishen, P. R., “Transient radiation from pistons in an infinite planar baffle”, J. Acoust. Soc. Am., Vol. 49 (5B), p. 1629, 1971.
  8. Strutt, J. W., “The Theory of Sound”, Vol. 2, Edit. MacMillian & Co., Second Edition, 1896.
  9. Sushilov, Nikolai V., Tavakkoli, J., Cobbold R. S. C., “New X-wave solutions of free-space scalar wave equation and their finite size realization”, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, Vol. 48, No. 1, p. 274-284, 2001.
  10. Ullate, L. G., Ramos, A., San Emeterio, J. L., “Analysis of the ultrasonic field radiated by time - delay cylindrically focused linear arrays”. IEEE Trans. Ultrason. Ferroelec. Freq. Control., Vol. 41, nº 5, p. 749-760, 1994.
Download


Paper Citation


in Harvard Style

Castellanos L., Ramos A. and Calás H. (2010). SYNTHESIS OF DRIVING SIGNALS FOR MEDICAL IMAGING ANNULAR ARRAYS FROM ULTRASONIC X-WAVE SOLUTIONS . In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 290-295. DOI: 10.5220/0002746802900295


in Bibtex Style

@conference{biosignals10,
author={l. Castellanos and A. Ramos and H. Calás},
title={SYNTHESIS OF DRIVING SIGNALS FOR MEDICAL IMAGING ANNULAR ARRAYS FROM ULTRASONIC X-WAVE SOLUTIONS},
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={290-295},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002746802900295},
isbn={978-989-674-018-4},
}


in EndNote Style

TY - CONF
JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - SYNTHESIS OF DRIVING SIGNALS FOR MEDICAL IMAGING ANNULAR ARRAYS FROM ULTRASONIC X-WAVE SOLUTIONS
SN - 978-989-674-018-4
AU - Castellanos L.
AU - Ramos A.
AU - Calás H.
PY - 2010
SP - 290
EP - 295
DO - 10.5220/0002746802900295