loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: J. A. Miguel ; R. Mozuelos and M. Martinez

Affiliation: University of Cantabria, Spain

Keyword(s): Biomedical transducers, Implantable biomedical devices, Cardiology.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instruments and Devices ; Biomedical Sensors ; Devices ; Health Monitoring Devices ; Human-Computer Interaction ; Implantable Electronics ; Physiological Computing Systems

Abstract: This paper presents a simplified MatLab model of an implantable device for pulmonary artery blood flow velocity measurement. A comparative review of the most popular blood flow measurement techniques has been carried out, showing the better suitability of pressure-sensing approaches to provide useful information to cardiovascular diseases monitorization. Different possible grades of stenosis in the pulmonary artery have been simulated in order to obtain an early estimation of the device behavior under real conditions.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.143.237.140

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
A. Miguel, J.; Mozuelos, R. and Martinez, M. (2012). BEHAVIOURAL ANALYSIS OF AN IMPLANTABLE FLOW AND PRESSURE SENSING DEVICE. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2012) - BIODEVICES; ISBN 978-989-8425-91-1; ISSN 2184-4305, SciTePress, pages 269-273. DOI: 10.5220/0003873902690273

@conference{biodevices12,
author={J. {A. Miguel}. and R. Mozuelos. and M. Martinez.},
title={BEHAVIOURAL ANALYSIS OF AN IMPLANTABLE FLOW AND PRESSURE SENSING DEVICE},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2012) - BIODEVICES},
year={2012},
pages={269-273},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003873902690273},
isbn={978-989-8425-91-1},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2012) - BIODEVICES
TI - BEHAVIOURAL ANALYSIS OF AN IMPLANTABLE FLOW AND PRESSURE SENSING DEVICE
SN - 978-989-8425-91-1
IS - 2184-4305
AU - A. Miguel, J.
AU - Mozuelos, R.
AU - Martinez, M.
PY - 2012
SP - 269
EP - 273
DO - 10.5220/0003873902690273
PB - SciTePress