loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Tsuneo Urisu 1 ; Hidetaka Uno 1 ; Zhi-Hong Wang 1 ; Senthil Kumar Obuliraj 1 ; Noriko Takada 2 ; Masaki Aoyama 2 ; Mitsukazu Suzui 2 ; Toshifumi Asano 3 ; Toru Ishizuka 3 and Hiromu Yawo 3

Affiliations: 1 Nagoya University, JST and CREST, Japan ; 2 Institute for Molecular Science, JST and CREST, Japan ; 3 Tohoku University, JST and CREST, Japan

Keyword(s): Planar patch clamp, Ionchannel, Biosensor, HEK293, TRPV1, PMMA.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instruments and Devices ; Biomedical Sensors ; Hardware ; MEMS ; Sensor Networks

Abstract: The biosensors based on the incubation type planar patch clamp method was developed and the basic properties were investigated. Usefulness of light-gated ionchannel method on the performance of the device was confirmed. The excess current noise and the thermal noise due to the micropore resistance and the seal resistance were the main sources of the noise, and the noise level of the developed biosensor was 7 pA at the 1 kHz low pass filter. This value is slightly larger than the single ionchannel current level (~4pA) of TRPV1. We consider that the developed device has a sufficient performance for the whole cell measurements, and extremely suitable for the high throughput screening application with neural network, in which incubation function is essentially necessary.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.145.206.169

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Urisu, T.; Uno, H.; Wang, Z.; Obuliraj, S.; Takada, N.; Aoyama, M.; Suzui, M.; Asano, T.; Ishizuka, T. and Yawo, H. (2012). INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2012) - BIODEVICES; ISBN 978-989-8425-91-1; ISSN 2184-4305, SciTePress, pages 143-148. DOI: 10.5220/0003764301430148

@conference{biodevices12,
author={Tsuneo Urisu. and Hidetaka Uno. and Zhi{-}Hong Wang. and Senthil Kumar Obuliraj. and Noriko Takada. and Masaki Aoyama. and Mitsukazu Suzui. and Toshifumi Asano. and Toru Ishizuka. and Hiromu Yawo.},
title={INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2012) - BIODEVICES},
year={2012},
pages={143-148},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003764301430148},
isbn={978-989-8425-91-1},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2012) - BIODEVICES
TI - INCUBATION TYPE PLANAR PATCH CLAMP BIOSENSOR - Basic Performances
SN - 978-989-8425-91-1
IS - 2184-4305
AU - Urisu, T.
AU - Uno, H.
AU - Wang, Z.
AU - Obuliraj, S.
AU - Takada, N.
AU - Aoyama, M.
AU - Suzui, M.
AU - Asano, T.
AU - Ishizuka, T.
AU - Yawo, H.
PY - 2012
SP - 143
EP - 148
DO - 10.5220/0003764301430148
PB - SciTePress