loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Gonzalo Tapia ; Matias Salinas ; Jaime Plaza ; Diego Mellado ; Rodrigo Salas ; Carolina Saavedra ; Alejandro Veloz ; Alexis Arriola ; Juan Idiaquez and Antonio Glaría

Affiliation: U. de Valparaíso, Chile

Keyword(s): VPG, nImI, Arterial Hypertension, Fractional Derivatives, Finapres, Photoplethysmography Derivatives.

Abstract: The purpose of this work is to fit Photoplethysmography (PPG) to finger Arterial Pressure (fiAP) waveform using derivative approaches. Derivative approaches consider using Linear Combination of Derivatives (LCD) and Fractional Derivatives (FDPa). Four informed healthy subjects, aging 35:811:0 years old, agreed to perform Handgrip maneuvers. Signals are recorded continually; a Finapres NOVA device is used for fiAP, while a BIOPAC System is used for PPG and ECG. PPG is smoothed and segmented by heartbeat; recording sections interfered with spiky blocking noise, are eliminated. Finally, PPG is processed using LCD and FDPa and their results are enriched using Lasso technique. Twenty records per subject at rest and twenty at raised BP are analyzed. Results show PPG to fiAP fitting errors 5:38%0:91 at resting fiAP and 5:86%1:21 at raised fiAP, being always lower than 15%, suggesting that derivative approaches could be suitable for medical applications.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.144.42.174

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Tapia, G.; Salinas, M.; Plaza, J.; Mellado, D.; Salas, R.; Saavedra, C.; Veloz, A.; Arriola, A.; Idiaquez, J. and Glaría, A. (2017). Photoplethysmogram Fits Finger Blood Pressure Waveform for non-Invasive and minimally-Intrusive Technologies. In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIOSIGNALS; ISBN 978-989-758-212-7; ISSN 2184-4305, SciTePress, pages 155-162. DOI: 10.5220/0006143901550162

@conference{biosignals17,
author={Gonzalo Tapia. and Matias Salinas. and Jaime Plaza. and Diego Mellado. and Rodrigo Salas. and Carolina Saavedra. and Alejandro Veloz. and Alexis Arriola. and Juan Idiaquez. and Antonio Glaría.},
title={Photoplethysmogram Fits Finger Blood Pressure Waveform for non-Invasive and minimally-Intrusive Technologies},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIOSIGNALS},
year={2017},
pages={155-162},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006143901550162},
isbn={978-989-758-212-7},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2017) - BIOSIGNALS
TI - Photoplethysmogram Fits Finger Blood Pressure Waveform for non-Invasive and minimally-Intrusive Technologies
SN - 978-989-758-212-7
IS - 2184-4305
AU - Tapia, G.
AU - Salinas, M.
AU - Plaza, J.
AU - Mellado, D.
AU - Salas, R.
AU - Saavedra, C.
AU - Veloz, A.
AU - Arriola, A.
AU - Idiaquez, J.
AU - Glaría, A.
PY - 2017
SP - 155
EP - 162
DO - 10.5220/0006143901550162
PB - SciTePress