Authors: J. Garcia-Casado 1 ; V. Zena 1 ; G. Prats-Boluda 1 ; Y. Ye-Lin 1 and E. Garcia-Breijo 2

Affiliations: 1 Grupo de Bioelectrónica, Spain ; 2 Centro de Reconoc. Molec. y Desarrollo Tecnológico and Ud Mixta UPV-UV, Spain

Keyword(s): Ring Electrode, Laplacian Recording, Non-invasive Myoelecrical Recording, Electroenterogram.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Biomedical Sensors

Abstract: The estimation of laplacian potential on the body surface obtained by means of concentric ring electrodes can provide bioelectrical signals with better spatial resolution and less affected by bioelectrical interferences than monopolar and bipolar recordings with conventional disc electrodes. These ringed electrodes are usually implemented on rigid substrates which cannot adapt to body surface curvature. In this paper an array of flexible concentric ring electrodes for non-invasive bioelectrical activity recordings is presented. The array contains three tripolar electrodes in bipolar configuration (TCB, inner disc and external ring are shorted) which is suitable for body surface mapping. A preconditioning circuit module is directly connected to the electrode array to perform a first stage of filtering and amplification as close as possible to the recording area. Simultaneous recordings of intestinal myoelectrical activity (electroenterogram, EEnG) by means of the flexible array of rin ged-electrodes and by disc electrodes with gel were carried out in healthy volunteers in fast state. Signals from the developed array of electrodes presented lower electrocardiographic and respiratory interference than conventional bipolar recordings with disc electrodes. The small bowel’s slow wave myoelectrical activity can be identified more easily in the ringed-electrodes recordings. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 44.212.94.2

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Garcia-Casado, J.; Zena, V.; Prats-Boluda, G.; Ye-Lin, Y. and Garcia-Breijo, E. (2013). Flexible Array of Active Concentric Ring Electrodes for Surface Bioelectrical Recordings - Application to Non-invasive Recordings of EEnG. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2013) - BIODEVICES; ISBN 978-989-8565-34-1; ISSN 2184-4305, SciTePress, pages 21-27. DOI: 10.5220/0004196500210027

@conference{biodevices13,
author={J. Garcia{-}Casado. and V. Zena. and G. Prats{-}Boluda. and Y. Ye{-}Lin. and E. Garcia{-}Breijo.},
title={Flexible Array of Active Concentric Ring Electrodes for Surface Bioelectrical Recordings - Application to Non-invasive Recordings of EEnG},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2013) - BIODEVICES},
year={2013},
pages={21-27},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004196500210027},
isbn={978-989-8565-34-1},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2013) - BIODEVICES
TI - Flexible Array of Active Concentric Ring Electrodes for Surface Bioelectrical Recordings - Application to Non-invasive Recordings of EEnG
SN - 978-989-8565-34-1
IS - 2184-4305
AU - Garcia-Casado, J.
AU - Zena, V.
AU - Prats-Boluda, G.
AU - Ye-Lin, Y.
AU - Garcia-Breijo, E.
PY - 2013
SP - 21
EP - 27
DO - 10.5220/0004196500210027
PB - SciTePress