loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Tiago Rodrigues 1 ; Hugo Silva 2 and Ana Fred 2

Affiliations: 1 Advanced Sport Instruments SA, Avenue de Beaumont 5, 1012 Lausanne, Switzerland ; 2 IT - Instituto de Telecomunicaç ões, Av. Rovisco Pais n. 1, Torre Norte - Piso 10, 1049-001 Lisboa, Portugal

Keyword(s): Electrocardiogram, R-peak Detector, Wearable Devices, Heart Rate Variability.

Abstract: The R-peak detection in an Electrocardiography (ECG) signal is of great importance for Heart Rate Variability (HRV) studies and feature extraction based on fiducial points. In this paper, a real-time and low-complexity algorithm for R-peak detection is evaluated on single lead ECG signals. The method is divided in a pre-processing and a detection stage. First, the pre-processing is based on a double differentiating step, squaring and moving window integration for QRS complex enhancement. Secondly, the detection stage is based on a finite state machine (FSM) with an adaptive thresholding for R-peak detection. The tested approach was benchmarked in a private FieldWiz Database with other commonly used QRS detectors, and later evaluated in the Physionet Databases (mitdb, nstdb, ltstdb and CinC Challenge 2014). The proposed approach resulted in a Sensivitity (Se) of 99.77% and Positive Predictive Value (PPV) of 99.18% in the FieldWiz database, comparable with the evaluated state of the ar t QRS detectors. In the Physionet Databases, the results showed to be highly influenced by the QRS waveform, for MIT-BIH (MITDB) achieving a median PPV of 99.79% and a median Se of 99.52%, with overall PPV of 98.35% and Se of 97.62%. The evaluated method can be implemented in wearable systems for cardiovascular tracking devices in dynamic use cases with good quality ECG signals, achieving comparable results to state of the art detectors. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.191.165.192

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Rodrigues, T.; Silva, H. and Fred, A. (2020). R-peak Detector Benchmarking using FieldWiz Device and Physionet Databases. In Proceedings of the 12th International Joint Conference on Knowledge Discovery, Knowledge Engineering and Knowledge Management (IC3K 2020) - KDIR; ISBN 978-989-758-474-9; ISSN 2184-3228, SciTePress, pages 302-309. DOI: 10.5220/0010147103020309

@conference{kdir20,
author={Tiago Rodrigues. and Hugo Silva. and Ana Fred.},
title={R-peak Detector Benchmarking using FieldWiz Device and Physionet Databases},
booktitle={Proceedings of the 12th International Joint Conference on Knowledge Discovery, Knowledge Engineering and Knowledge Management (IC3K 2020) - KDIR},
year={2020},
pages={302-309},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0010147103020309},
isbn={978-989-758-474-9},
issn={2184-3228},
}

TY - CONF

JO - Proceedings of the 12th International Joint Conference on Knowledge Discovery, Knowledge Engineering and Knowledge Management (IC3K 2020) - KDIR
TI - R-peak Detector Benchmarking using FieldWiz Device and Physionet Databases
SN - 978-989-758-474-9
IS - 2184-3228
AU - Rodrigues, T.
AU - Silva, H.
AU - Fred, A.
PY - 2020
SP - 302
EP - 309
DO - 10.5220/0010147103020309
PB - SciTePress