loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Anita Finnegan ; Fergal Mc Caffery and Gerry Coleman

Affiliation: Dundalk Institute of Technology & Lero, Ireland

Keyword(s): Medical Device Security, Process Assessment, ISO/IEC 15026-2, ISO/IEC 15026-4, IEC 80001-2-2, IEC 62443-3-3, ISO/IEC 15504, ISO 27799, ISO/IEC 27001, ISO/IEC 27002.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Design and Development Methodologies for Healthcare IT ; Health Information Systems

Abstract: Advancements in medical device design over the last number of years have allowed medical device manufacturers to add more complex functionality particularly through the use of software. Such advancements include the ability for devices to communicate wirelessly across networks, from device to device and over the Internet. However, with such advancements comes additional risks; these are security risks, vulnerabilities and threats. In the past twelve months, concern within the medical device community has led to the US Government calling upon the FDA to take responsibility of medical device security. In support of this, this position paper details a research proposal to address medical device security issues through the development of a Process Reference Model (PRM) and a Process Assessment Model (PAM) to assess the capability of the processes used to develop medical devices intended to be incorporated onto healthcare networks and also determine the product security capability thro ugh the development of security assurance cases created following the lifecycle process. Further, in support of IEC 80001-2-2, the output from this PRM will be an assurance case with a security assurance level, which will be used to communicate the security capabilities of the product between Medical Device Manufacturers (MDMs) and Healthcare Delivery Organisations (HDOs). The intent is to build a better awareness of vulnerability types, threats and related risks to assist in reducing the likelihood of harm resulting from a security risk. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.133.124.23

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Finnegan, A.; Mc Caffery, F. and Coleman, G. (2013). Development of a Process Assessment Model for Assessing Security of IT Networks Incorporating Medical Devices against ISO/IEC 15026-4. In Proceedings of the International Conference on Health Informatics (BIOSTEC 2013) - HEALTHINF; ISBN 978-989-8565-37-2; ISSN 2184-4305, SciTePress, pages 250-255. DOI: 10.5220/0004327502500255

@conference{healthinf13,
author={Anita Finnegan. and Fergal {Mc Caffery}. and Gerry Coleman.},
title={Development of a Process Assessment Model for Assessing Security of IT Networks Incorporating Medical Devices against ISO/IEC 15026-4},
booktitle={Proceedings of the International Conference on Health Informatics (BIOSTEC 2013) - HEALTHINF},
year={2013},
pages={250-255},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004327502500255},
isbn={978-989-8565-37-2},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Health Informatics (BIOSTEC 2013) - HEALTHINF
TI - Development of a Process Assessment Model for Assessing Security of IT Networks Incorporating Medical Devices against ISO/IEC 15026-4
SN - 978-989-8565-37-2
IS - 2184-4305
AU - Finnegan, A.
AU - Mc Caffery, F.
AU - Coleman, G.
PY - 2013
SP - 250
EP - 255
DO - 10.5220/0004327502500255
PB - SciTePress