Authors: Birutė Paliakaitė 1 ; Andrius Petrėnas 1 ; Jurgita Skibarkienė 2 ; Tomas Mickus 1 ; Saulius Daukantas 1 ; Raimondas Kubilius 2 and Vaidotas Marozas 1

Affiliations: 1 Kaunas University of Technology, Lithuania ; 2 Hospital of the Lithuanian University of Health Sciences Kaunas Clinics, Lithuania

ISBN: 978-989-758-212-7

Keyword(s): Atrial Fibrillation Detection, Sample Entropy, Photoplethysmogram, Wearable Device, Accelerometer.

Related Ontology Subjects/Areas/Topics: Applications and Services ; Biomedical Engineering ; Biomedical Signal Processing ; Cardiovascular Signals ; Computer Vision, Visualization and Computer Graphics ; Devices ; Health Information Systems ; Human-Computer Interaction ; Medical Image Detection, Acquisition, Analysis and Processing ; Monitoring and Telemetry ; Physiological Computing Systems ; Wearable Sensors and Systems

Abstract: This study investigates the feasibility of long-term monitoring of atrial fibrillation (AF) using wrist-worn device, capable of acquiring photoplethysmogram (PPG) and motion data. Moreover, the performance of AF detectors, initially developed to detect AF in electrocardiogram (ECG) signals, is evaluated on PPG. The study population consisted of 12 patients undergoing cardiac rehabilitation. Based on accelerometer data, 65% of recording time was considered as motion-free, which resulted in 86.8 hours of data with AF and 85.4 hours without. The performance of AF detectors was found to be comparable when both ECG and PPG are used for constructing heart rhythm series. Considering that 2/3 of monitoring time PPG was of satisfactory quality, the wrist-worn device has potential to be applied for long-term mass screening of target population.

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 35.175.200.4

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Paliakaitė, B.; Petrėnas, A.; Skibarkienė, J.; Mickus, T.; Daukantas, S.; Kubilius, R. and Marozas, V. (2017). Towards Long-term Monitoring of Atrial Fibrillation using Photoplethysmography.In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2017) ISBN 978-989-758-212-7, pages 141-146. DOI: 10.5220/0006115601410146

@conference{biosignals17,
author={Birutė Paliakaitė. and Andrius Petrėnas. and Jurgita Skibarkienė. and Tomas Mickus. and Saulius Daukantas. and Raimondas Kubilius. and Vaidotas Marozas.},
title={Towards Long-term Monitoring of Atrial Fibrillation using Photoplethysmography},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2017)},
year={2017},
pages={141-146},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006115601410146},
isbn={978-989-758-212-7},
}

TY - CONF

JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2017)
TI - Towards Long-term Monitoring of Atrial Fibrillation using Photoplethysmography
SN - 978-989-758-212-7
AU - Paliakaitė, B.
AU - Petrėnas, A.
AU - Skibarkienė, J.
AU - Mickus, T.
AU - Daukantas, S.
AU - Kubilius, R.
AU - Marozas, V.
PY - 2017
SP - 141
EP - 146
DO - 10.5220/0006115601410146