loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Alexandra-Maria Tautan 1 ; Vojkan Mihajlovic 2 ; Yun-Hsuan Chen 3 ; Bernard Grundlehner 2 ; Julien Penders 2 and Wouter Serdijn 1

Affiliations: 1 Delft University of Technology, Netherlands ; 2 Holst Centre / imec-nl, Netherlands ; 3 imec, Belgium

Keyword(s): EEG, Dry Electrodes, Gel Electrodes, Signal Quality, Evaluation Framework, SSVEPs, Skin-electrode Contact Impedance, SNR, Correlations, Coherence.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instruments and Devices ; Biomedical Sensors ; Brain-Computer Interfaces ; Devices ; Human-Computer Interaction ; Physiological Computing Systems ; Technologies Evaluation ; Wireless Systems

Abstract: Current EEG research approaches are focusing on developing new dry electrode EEG (electroencephalogram) systems providing a high enough signal quality for a wide range of applications. This study proposes several parameters for evaluating signal quality of dry electrodes and relates the results to skin-electrode contact impedance magnitude values. The EEG recordings of a Ag/AgCl pinned electrode and a flexible polymer pinned electrode are evaluated through a comparison to conductive gel electrode recordings. The experimental setup was made up of two EEG acquisition systems connected in parallel. The protocol included open eyes, closed eyes and steady-state visually evoked potentials (SSVEP) sessions in both seated and walking in place conditions. The parameters used for evaluation were signal correlations, signal coherence and signal-to-noise ratios (SNRs). Results showed that the three proposed parameters provided equivalent outcome for signal quality estimation for the same record ings. There was no relation reported between the defined signal quality and the skin-electrode contact impedance in either dry or gel electrodes, although high impedance variations were present among subjects. However, larger impedance magnitude and impedance magnitude variations, and lower signal quality is observed for dry electrodes compared to gel ones. (More)

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.15.31.27

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Tautan, A.; Mihajlovic, V.; Chen, Y.; Grundlehner, B.; Penders, J. and Serdijn, W. (2014). Signal Quality in Dry Electrode EEG and the Relation to Skin-electrode Contact Impedance Magnitude. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - BIODEVICES; ISBN 978-989-758-013-0; ISSN 2184-4305, SciTePress, pages 12-22. DOI: 10.5220/0004738700120022

@conference{biodevices14,
author={Alexandra{-}Maria Tautan. and Vojkan Mihajlovic. and Yun{-}Hsuan Chen. and Bernard Grundlehner. and Julien Penders. and Wouter Serdijn.},
title={Signal Quality in Dry Electrode EEG and the Relation to Skin-electrode Contact Impedance Magnitude},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - BIODEVICES},
year={2014},
pages={12-22},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004738700120022},
isbn={978-989-758-013-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2014) - BIODEVICES
TI - Signal Quality in Dry Electrode EEG and the Relation to Skin-electrode Contact Impedance Magnitude
SN - 978-989-758-013-0
IS - 2184-4305
AU - Tautan, A.
AU - Mihajlovic, V.
AU - Chen, Y.
AU - Grundlehner, B.
AU - Penders, J.
AU - Serdijn, W.
PY - 2014
SP - 12
EP - 22
DO - 10.5220/0004738700120022
PB - SciTePress