loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Timo Salpavaara ; Ville Ellä ; Minna Kellomäki and Jukka Lekkala

Affiliation: Tampere University of Technology, Finland

Keyword(s): Biodegradable, Passive Resonance Sensor.

Related Ontology Subjects/Areas/Topics: Biomaterials ; Biomedical Engineering ; Biomedical Instruments and Devices ; Implantable Electronics ; Wireless Systems

Abstract: Biodegradable resonance circuits were studied. The circuits have a novel two-layer resonator structure without galvanic through hole vias. A patterned magnesium layers were evaporated on biodegradable PLA sheets by using a 3D printed mask. The circuits were assembled by heat sealing two magnesium patterned sheets together to encapsulate the circuit structure. An inductive link is used to wirelessly detect the resonance frequency of the circuit. The circuits were tested when immersed in de-ionised water and saline. According to the tests, the designed resonator structure can be measured in aqueous environment. The resonance of the tested circuit was observable at least for 51 hours. The concept still needs more development to extend degradation time and to increase the stability during immersion.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 18.118.184.237

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Salpavaara, T.; Ellä, V.; Kellomäki, M. and Lekkala, J. (2015). Biodegradable Passive Resonance Sensor - Fabrication and Initial Testing. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2015) - BIODEVICES; ISBN 978-989-758-071-0; ISSN 2184-4305, SciTePress, pages 127-131. DOI: 10.5220/0005255901270131

@conference{biodevices15,
author={Timo Salpavaara. and Ville Ellä. and Minna Kellomäki. and Jukka Lekkala.},
title={Biodegradable Passive Resonance Sensor - Fabrication and Initial Testing},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2015) - BIODEVICES},
year={2015},
pages={127-131},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005255901270131},
isbn={978-989-758-071-0},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2015) - BIODEVICES
TI - Biodegradable Passive Resonance Sensor - Fabrication and Initial Testing
SN - 978-989-758-071-0
IS - 2184-4305
AU - Salpavaara, T.
AU - Ellä, V.
AU - Kellomäki, M.
AU - Lekkala, J.
PY - 2015
SP - 127
EP - 131
DO - 10.5220/0005255901270131
PB - SciTePress