loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Renata Manzano Maria 1 ; Karina Cristina Alonso 2 ; Eliza Regina Ferreira Braga Machado de Azevedo 2 ; Renato Varoto 1 and Alberto Cliquet Jr. 1

Affiliations: 1 University of São Paulo (USP), Brazil ; 2 University of Campinas (UNICAMP), Brazil

Keyword(s): Spasticity, Pendulum Test, Biomedical Engineering, Electrogoniometer, Goniometry, Accelerometer, Spinal Cord Injury, Clinical Evaluation.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Instrumentation ; Biomedical Instruments and Devices ; Biomedical Sensors ; Devices ; Health Monitoring Devices ; Human-Computer Interaction ; Physiological Computing Systems ; Technologies Evaluation

Abstract: The proposal of this project was the development of a more objective system to evaluate spasticity, dysfunction often presented by spinal cord injured people. As result, it will be possible to follow patient’s progress in moments before and after any treatment, drawing comparisons through the acquired data. One accelerometer was added to the original pendulum test, providing redundant and alternative signal to the electrogoniometer, even in critical situations. Also, tests were performed in patients during treatments, what confirmed the feasibility of the present system in this method of evaluation.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 13.58.200.16

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Manzano Maria, R.; Alonso, K.; Ferreira Braga Machado de Azevedo, E.; Varoto, R. and Cliquet Jr., A. (2013). Custom Built Device for Spasticity Evaluation Associated to Spinal Cord Injury - A Redundant Signal to Electrogoniometer in Pendulum Test. In Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2013) - BIODEVICES; ISBN 978-989-8565-34-1; ISSN 2184-4305, SciTePress, pages 120-126. DOI: 10.5220/0004234001200126

@conference{biodevices13,
author={Renata {Manzano Maria}. and Karina Cristina Alonso. and Eliza Regina {Ferreira Braga Machado de Azevedo}. and Renato Varoto. and Alberto {Cliquet Jr.}.},
title={Custom Built Device for Spasticity Evaluation Associated to Spinal Cord Injury - A Redundant Signal to Electrogoniometer in Pendulum Test},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2013) - BIODEVICES},
year={2013},
pages={120-126},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004234001200126},
isbn={978-989-8565-34-1},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the International Conference on Biomedical Electronics and Devices (BIOSTEC 2013) - BIODEVICES
TI - Custom Built Device for Spasticity Evaluation Associated to Spinal Cord Injury - A Redundant Signal to Electrogoniometer in Pendulum Test
SN - 978-989-8565-34-1
IS - 2184-4305
AU - Manzano Maria, R.
AU - Alonso, K.
AU - Ferreira Braga Machado de Azevedo, E.
AU - Varoto, R.
AU - Cliquet Jr., A.
PY - 2013
SP - 120
EP - 126
DO - 10.5220/0004234001200126
PB - SciTePress