loading
Papers Papers/2022 Papers Papers/2022

Research.Publish.Connect.

Paper

Paper Unlock

Authors: Halil Ibrahim Çakar ; Sadık Kara and Onur Toker

Affiliation: Fatih University, Turkey

Keyword(s): Surface Electromyography, Back Herniation, Biomedical Instrumentation.

Related Ontology Subjects/Areas/Topics: Biomedical Engineering ; Biomedical Equipment ; Biomedical Instrumentation ; Biomedical Instruments and Devices

Abstract: Up to 80 percent of people are affected by back herniation or another low-back disease in their life. Some studies have proven that there is a significant relation between paraspinal muscles and back herniation. In this study, a portable surface electromyography device was designed for measuring the muscular activity of paraspinal muscles from back herniated patients. The device’s gain value is adjusted to 1000, it includes a band-pass filter and a 50 Hz notch filter to eliminate power source interference noise and other electrically noises. The device designed as an electrically isolated single channel, and it is linked to Matlab software via the serial port of Personal Computer.

CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.129.247.250

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Çakar, H.; Kara, S. and Toker, O. (2010). DESIGN OF A PORTABLE ELECTROMYOGRAPHY DEVICE FOR BACK HERNIATED PATIENTS. In Proceedings of the Third International Conference on Biomedical Electronics and Devices (BIOSTEC 2010) - BIODEVICES; ISBN 978-989-674-017-7; ISSN 2184-4305, SciTePress, pages 94-97. DOI: 10.5220/0002718100940097

@conference{biodevices10,
author={Halil Ibrahim \c{C}akar. and Sadık Kara. and Onur Toker.},
title={DESIGN OF A PORTABLE ELECTROMYOGRAPHY DEVICE FOR BACK HERNIATED PATIENTS},
booktitle={Proceedings of the Third International Conference on Biomedical Electronics and Devices (BIOSTEC 2010) - BIODEVICES},
year={2010},
pages={94-97},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002718100940097},
isbn={978-989-674-017-7},
issn={2184-4305},
}

TY - CONF

JO - Proceedings of the Third International Conference on Biomedical Electronics and Devices (BIOSTEC 2010) - BIODEVICES
TI - DESIGN OF A PORTABLE ELECTROMYOGRAPHY DEVICE FOR BACK HERNIATED PATIENTS
SN - 978-989-674-017-7
IS - 2184-4305
AU - Çakar, H.
AU - Kara, S.
AU - Toker, O.
PY - 2010
SP - 94
EP - 97
DO - 10.5220/0002718100940097
PB - SciTePress