Authors: V. Antsiperov 1 ; G. Mansurov 2 ; M. Danilychev 2 and D. Churikov 3

Affiliations: 1 Kotelnikov Institute of Radio Engineering and Electronics of RAS, Moscow, Russia, Moscow Institute of Physics and Technology, Moscow, Russia ; 2 Kotelnikov Institute of Radio Engineering and Electronics of RAS, Moscow, Russia ; 3 Kotelnikov Institute of Radio Engineering and Electronics of RAS, Moscow, Russia, Moscow Institute of Physics and Technology, Moscow, Russia, Scientific and Technological Centre of Unique Instrumentation of the RAS, Moscow, Russia

ISBN: 978-989-758-353-7

Keyword(s): Blood Pressure Non-Invasive Measurement, Continues Pulse-Waveform Monitoring, Local Pressure Compensation Principle, Pneumatic Pressure Sensor, Sensor Positioning Problem, Multichannel Measurements and Control.

Abstract: The main goal of the paper is to present a new type of a sensor for non-invasive continuous blood pressure measurements. The principle of such a sensor operation, based on local pressure compensation, is in the centre of discussion. The sensor presented has very small sensing pads (1 mm2 or less) which permits accurate sensor positioning directly on the elastic surfaces such as the human skin. Thanks to that it is possible to provide a high quality of the blood pressure measurement, when keeping the continuity of the measurement parameters and minimizing the level of disturbances. For this reason, the paper focuses on a detailed discussion of the positioning problem and the results of developing approaches to its solving. As a promising method, a positioning based on the pulse wave controlling by a three-chamber pneumatic sensor is proposed.

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.227.240.31

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Antsiperov, V.; Mansurov, G.; Danilychev, M. and Churikov, D. (2019). Non-Invasive Blood Pressure Monitoring with Positionable Three-chamber Pneumatic Sensor.In Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 5: HEALTHINF, ISBN 978-989-758-353-7, pages 462-465. DOI: 10.5220/0007574904620465

@conference{healthinf19,
author={V. E. Antsiperov. and G. K. Mansurov. and M. V. Danilychev. and D. V. Churikov.},
title={Non-Invasive Blood Pressure Monitoring with Positionable Three-chamber Pneumatic Sensor},
booktitle={Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 5: HEALTHINF,},
year={2019},
pages={462-465},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0007574904620465},
isbn={978-989-758-353-7},
}

TY - CONF

JO - Proceedings of the 12th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 5: HEALTHINF,
TI - Non-Invasive Blood Pressure Monitoring with Positionable Three-chamber Pneumatic Sensor
SN - 978-989-758-353-7
AU - Antsiperov, V.
AU - Mansurov, G.
AU - Danilychev, M.
AU - Churikov, D.
PY - 2019
SP - 462
EP - 465
DO - 10.5220/0007574904620465

Login or register to post comments.

Comments on this Paper: Be the first to review this paper.