loading
Papers

Research.Publish.Connect.

Paper

Authors: Maciej Browarczyk 1 ; Renata Kalicka 1 and Seweryn Lipiński 2

Affiliations: 1 Gdańsk University of Technology, Poland ; 2 University of Warmia and Mazury, Poland

ISBN: 978-989-758-212-7

Keyword(s): Modelling, pCT, Gamma-Variate, Gauss, Rayleigh.

Related Ontology Subjects/Areas/Topics: Applications and Services ; Biomedical Engineering ; Biomedical Signal Processing ; Computer Vision, Visualization and Computer Graphics ; Medical Image Detection, Acquisition, Analysis and Processing ; Physiological Processes and Bio-Signal Modeling, Non-Linear Dynamics

Abstract: Perfusion computed tomography (pCT) is one of the methods that enable non-invasive imaging of the hemodynamics of organs and tissues. On the basis of pCT measurements, perfusion parameters such as blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface (PS) are calculated and then used for quantitative evaluation of the tissue condition. To calculate perfusion parameters it is necessary to approximate concentration-time curves using regression function. In this paper we compared three regression functions: first commonly used gamma-variate function, second and third Gauss and Rayleigh functions, not previously used for this purpose. The Gauss function showed clear advantage over the others when considering results of simulated data analysis. Actual measurements analysis confirmed conclusions from simulated data analysis. It was showed that contrary to widely accepted belief, the differences between rising and falling edge slope angles of concentration-time curves are inconsiderable. For that reason, it can be assumed that rising and falling edges are symmetrical. The main conclusion is that the Gauss function gives a more robust fit than the widely used gamma-variate function when modelling concentration-time curves in lung pCT studies. (More)

PDF ImageFull Text

Download
CC BY-NC-ND 4.0

Sign In Guest: Register as new SciTePress user now for free.

Sign In SciTePress user: please login.

PDF ImageMy Papers

You are not signed in, therefore limits apply to your IP address 3.209.80.87

In the current month:
Recent papers: 100 available of 100 total
2+ years older papers: 200 available of 200 total

Paper citation in several formats:
Browarczyk, M.; Kalicka, R. and Lipiński, S. (2017). Proposal of New Tracer Concentration Model in Lung PCT Study - Comparison with Commonly Used Gamma-variate Model.In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2017) ISBN 978-989-758-212-7, pages 134-140. DOI: 10.5220/0006115101340140

@conference{biosignals17,
author={Maciej Browarczyk. and Renata Kalicka. and Seweryn Lipiński.},
title={Proposal of New Tracer Concentration Model in Lung PCT Study - Comparison with Commonly Used Gamma-variate Model},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2017)},
year={2017},
pages={134-140},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006115101340140},
isbn={978-989-758-212-7},
}

TY - CONF

JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 4: BIOSIGNALS, (BIOSTEC 2017)
TI - Proposal of New Tracer Concentration Model in Lung PCT Study - Comparison with Commonly Used Gamma-variate Model
SN - 978-989-758-212-7
AU - Browarczyk, M.
AU - Kalicka, R.
AU - Lipiński, S.
PY - 2017
SP - 134
EP - 140
DO - 10.5220/0006115101340140

Login or register to post comments.