Abstract

Power transformer is a vital component of power system, which has no substitute for its major role. They are quite expensive also. It is therefore, very important to closely monitor it’s in – service behavior to avoid costly outages and loss of production. Many devices have evolved to monitor the serviceability of power transformers. These devices such as Buchholz relay or differential relay respond only to a severe power failure requiring immediate removal of transformer from service, in which case, outages are inevitable. Thus, preventive techniques for early detection of faults to avoid outages would be valuable. A prototype of an expert system based on Dissolved Gas Analysis (DGA) technique for diagnosis of suspected transformers faults and their maintenance action are developed. The synthetic method is proposed to assist the popular gas ratio methods. This expert system is implemented into PC by using “Turbo Prolog” with rule based knowledge representations. The designed expert system has been tested for N.T.P.C., Talcher (India) transformer’s gas ratio records to show its effectiveness in transformer diagnosis.

References

  1. E. Dornerburg, W.Strittmatter, Monitoring Oil Cooling Transformers by Gas Analysis, Brown Boveri Review, 61,pp 238-247,May 1974.
  2. R.R.Rogers, IEEE and IEC Codes to Interpret Incipient Faults in Transformers, Using Gas in Oil Analysis, IEEE Trans. E.I., Vol. EI -13, NO.-5,pp 349-354,oct 1978.
  3. M.Duval, Hydro-Qubec, It Can Save Your Transformer, IEEE Electrical Insulation Magazine, Vol.5, No.6, Nov/Dec 1989.
  4. ASTM Method D 3612, Analysis of Gases Dissolved in Electrical Insulating Oil by Gas Chromatography, 1979.
  5. G.Belanger, M.Duval, Monitor for Hydrogen dissolved in transformer Oil, 'Hydran' Available from Syprotech Inc., Canada, IEEE Trans. on Electrical Insulation, Vol E1-12, No.-5,pp 335-340,1977.
  6. H.Tsukioka, K.Sugawara, E. Mori, S.Hukumari, S.Sakau,New Apparatus for Detecting H2, CO, & CH4 Dissolved in Transformer Oil, IEEE Trans. Electrical Insulation, Vol. E1-18, No.4, pp 409-419, 1983.
  7. Yann- Chang Huang, Hong-Tza Yang, Ching-Lien Hnany, Developing a New Transformer Fault Diagnosis System Through Evolutionary Fuzzy Logic, IEEE Trans. on Power Delivery, Vol.12, No2, April 1997.
  8. ANSI / IEEE CS7.104-1978,Guide for the Detection and Determination of Generated Gases in Oil Immersed Transformer and Relating to the Serviceability of the Equipment.
Download


Paper Citation


in Harvard Style

K. Dhote N., M.Holey D. and R.Ramteke M. (2004). DEVELOPMENT OF AN EXPERT SYSTEM FOR DETECTING INCIPIENT FAULT IN TRANSFORMER BY DISSOLVED GAS ANALYSIS . In Proceedings of the Sixth International Conference on Enterprise Information Systems - Volume 2: ICEIS, ISBN 972-8865-00-7, pages 210-215. DOI: 10.5220/0002630302100215


in Bibtex Style

@conference{iceis04,
author={N. K. Dhote and D. M.Holey and M. R.Ramteke},
title={DEVELOPMENT OF AN EXPERT SYSTEM FOR DETECTING INCIPIENT FAULT IN TRANSFORMER BY DISSOLVED GAS ANALYSIS},
booktitle={Proceedings of the Sixth International Conference on Enterprise Information Systems - Volume 2: ICEIS,},
year={2004},
pages={210-215},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002630302100215},
isbn={972-8865-00-7},
}


in EndNote Style

TY - CONF
JO - Proceedings of the Sixth International Conference on Enterprise Information Systems - Volume 2: ICEIS,
TI - DEVELOPMENT OF AN EXPERT SYSTEM FOR DETECTING INCIPIENT FAULT IN TRANSFORMER BY DISSOLVED GAS ANALYSIS
SN - 972-8865-00-7
AU - K. Dhote N.
AU - M.Holey D.
AU - R.Ramteke M.
PY - 2004
SP - 210
EP - 215
DO - 10.5220/0002630302100215