VISION-BASED TRACKING SYSTEM FOR HEAD MOTION CORRECTION IN FMRI IMAGES
Tali Lerner, Ehud Rivlin, Moshe Gur
2006
Abstract
This paper presents a new vision-based system for motion correction in functional-MRI experiments. fMRI is a popular technique for studying brain functionality by utilizing MRI technology. In an fMRI experiment a subject is required to perform a task while his brain is scanned by an MRI scanner. In order to achieve a high quality analysis the fMRI slices should be aligned. Hence, the subject is requested to avoid head movements during the entire experiment. However, due to the long duration of such experiments head motion is practically unavoidable. Most of the previous work in this field addresses this problem by extracting the head motion parameters from the acquired MRI data. Therefore, these works are limited to relatively small movements and may confuse head motion with brain activities. In the present work the head movements are detected by a system comprised of two cameras that monitor a specially designed device worn on the subject’s head. The system does not depend on the acquired MRI data and therefore can overcome large head movements. Additionally, the system can be extended to cope with inter-block motion and can be integrated into the MRI scanner for real-time updates of the scan-planes. The performance of the proposed system was tested in a laboratory environment and in fMRI experiments. It was found that high accuracy is obtained even when facing large head movements.
References
- Bandettini, P., Wong, E., Hinks, R., Tikofsky, R., and Hyde, J. (1992). Time course epi of human brain function during task activation. Journal of Magn. Reson. Med., 25:390-397.
- Belliveau, J., Kennedy, D., McKinstry, R., Buchbinder, B., Weisskoff, R., Cohen, M., Vevea, J., Brady, T., and Rosen, B. (1991). Functional mapping of the human visual cortex by magnetic resonance imaging. Science, 254:716-719.
- Caparelli, E., Tomasi, D., Arnold, S., Chang, L., and Ernst, T. (2003). K-spaced based summary motion detection for functional magnetic resonance imaging. NeuroImage, 20:1411-1418.
- Ciulla, C. and Deek, F. (2002). Performance assessment of an algorithm for the alignment of fmri time series. Brain Tomography, 14:NO. 4.
- Derbyshire, J., Wright, G., Henkelman, R., and Hinks, R. (1998). Dynamic scan-plane tracking using mr position monitoring. Journal of Magn. Reson. Med., 5:924-932.
- Friston, K., William, S., Howard, R., Frackowiak, R., and Tuner, R. (1996). Movement-related effects in fmri time-series. Journal of Magn. Reson. Med., 35:346- 355.
- Hajnal, J., Saeed, N., Soar, E., Oatridge, A., Young, I., and Bydder, G. (1995). A registration and interpolation procedure for subvoxel matching of serially acquired mr images. Journal of Computer Assisted Tomography, 19:289-296.
- Hartley, R. and Zisserman, A. (2000). Multiple View Geometry in Computer Vision. Cambridge University Press, Cambridge.
- Kim, E., Park, N., Choi, M., and Tamura, S. (2002). Cancellation of mri motion artifact in image plane. In IEEE Intrumentation and Measurements.
- Thesen, S., Hied, O., Mueller, E., and Schad, L. (2000). Prospective acquisition correction for head tracking for real-time fmri. Journal of Magn. Reson. Med., 44:457-465.
- Umeyama, S. (1991). Least-squares estimation of transformation parameters between two point patterns. IEEE Trans. on Pattern Analysis and Machine Intelligence, 13,Journal of Computer Assisted Tomography:376- 380.
- Woods, R., Cherry, S., and Mazziotta, J. (1992). Rapid automated algorithm for aligning and reslicing pet images. Journal of Computer Assisted Tomography, 16:620- 633.
- Woods, R., Mazziotta, J., and Cherry, S. (1993). Mripet registration with automated algorithm. Journal of Computer Assisted Tomography, 17:536-546.
- Zoroofi, R., Sato, Y., S.Tamura, and Naito, H. (1996). Mri artifacts cancellation due to rigid motion in the imaging plane. IEEE Tran. on Medical Imaging, 15:NO. 6.
Paper Citation
in Harvard Style
Lerner T., Rivlin E. and Gur M. (2006). VISION-BASED TRACKING SYSTEM FOR HEAD MOTION CORRECTION IN FMRI IMAGES . In Proceedings of the First International Conference on Computer Vision Theory and Applications - Volume 2: VISAPP, ISBN 972-8865-40-6, pages 213-220. DOI: 10.5220/0001370202130220
in Bibtex Style
@conference{visapp06,
author={Tali Lerner and Ehud Rivlin and Moshe Gur},
title={VISION-BASED TRACKING SYSTEM FOR HEAD MOTION CORRECTION IN FMRI IMAGES},
booktitle={Proceedings of the First International Conference on Computer Vision Theory and Applications - Volume 2: VISAPP,},
year={2006},
pages={213-220},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001370202130220},
isbn={972-8865-40-6},
}
in EndNote Style
TY - CONF
JO - Proceedings of the First International Conference on Computer Vision Theory and Applications - Volume 2: VISAPP,
TI - VISION-BASED TRACKING SYSTEM FOR HEAD MOTION CORRECTION IN FMRI IMAGES
SN - 972-8865-40-6
AU - Lerner T.
AU - Rivlin E.
AU - Gur M.
PY - 2006
SP - 213
EP - 220