Abstract
Magnetic Resonance (MRI), Computed Tomography (CT) and Ultrasound (US) are three of the most commonly used clinical imaging modalities. The aim of this study was to establish a Quality Assurance program for MRI, CT and US scanners. A well-designed quality assurance program is of utmost importance in the clinical setting, because it indicates whether diagnostic imaging modalities meet the minimum criteria of acceptable performance and because it helps determine those scanner parameters that need adjustment in order to ensure optimum performance. Quality assurance programs that rely on manual data collection and analysis are tedious and time consuming and are often abandoned due to the significant workload required for their implementation. In this paper we describe an integrated software system for automating the process of data collection and management in Quality Assurance for diagnostic radiological imaging. The developed system is comprised of two main units: The Image Processing Unit (IPU) and the Data Management Unit (DMU). The IPU is used for analysing images from different diagnostic modalities in order to extract measurements. The IPU is dynamically linked to the DMU so that measurements are transferred directly to the DMU. This process allows the generation of quality assurance reports for all such modalities.
References
- Bourel P, Gibon D, Coste E, Daanen V, Rousseau J. 1999. Automatic quality assessment protocol for MRI Equipment. Med. Phys. 26(12):2693-700.
- Lerski RA, de Certaines JD. 1993. Performance assessment and quality control in MRI by Eurospin test objects and protocols. Magn. Reson. Imaging 11(6):817-33
- McRobbie DW, Quest RA. 2002. Effectiveness and relevance of MR acceptance testing: results of an 8- year audit. Br. J. Radiology 75(894):523-31.
- Och JG, Clarke GD, Sobol WT, et. Al , 1992 Acceptance testing of Magnetic Resonance Imaging systems: report of AAPM Nuclear Magnetic Resonance Task Group No. 6. Med. Phys. 18:217-229.
- Price RR, Axel L, Morgan T, et. al. 1990. Quality assurance methods and phantoms for magnetic resonance imaging:report of the AAPM Nuclear Magnetic ResonanceTask Group No. 1. Med. Phys. 17 (Mar/Apr):2.
- Radiology Centennial Inc., 1996, “A HISTORY OF THE RADIOLOGICAL SCIENCES 1996 3 Volumes, (American College of Radiology group)
Paper Citation
in Harvard Style
Constantinou C., Grondoudis A., Christoforou A., Constantinides C. and Lanitis A. (2006). A SEMI-AUTOMATED QUALITY ASSURANCE TOOLBOX FOR DIAGNOSTIC RADIOLOGICAL IMAGING . In Proceedings of the Eighth International Conference on Enterprise Information Systems - Volume 2: ICEIS, ISBN 978-972-8865-42-9, pages 216-221. DOI: 10.5220/0002445802160221
in Bibtex Style
@conference{iceis06,
author={Christodoulos Constantinou and Andreas Grondoudis and Andreas Christoforou and Christakis Constantinides and Andreas Lanitis},
title={A SEMI-AUTOMATED QUALITY ASSURANCE TOOLBOX FOR DIAGNOSTIC RADIOLOGICAL IMAGING},
booktitle={Proceedings of the Eighth International Conference on Enterprise Information Systems - Volume 2: ICEIS,},
year={2006},
pages={216-221},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002445802160221},
isbn={978-972-8865-42-9},
}
in EndNote Style
TY - CONF
JO - Proceedings of the Eighth International Conference on Enterprise Information Systems - Volume 2: ICEIS,
TI - A SEMI-AUTOMATED QUALITY ASSURANCE TOOLBOX FOR DIAGNOSTIC RADIOLOGICAL IMAGING
SN - 978-972-8865-42-9
AU - Constantinou C.
AU - Grondoudis A.
AU - Christoforou A.
AU - Constantinides C.
AU - Lanitis A.
PY - 2006
SP - 216
EP - 221
DO - 10.5220/0002445802160221