Further studies show cylindrical B-Spline can also
be used to fit the LV and the RV, even a vivid heart
might be represented by B-Spline model in the future.
It is valuable for the diagnoses of heart diseases, and
series of ongoing studies related on cardiac analysis
are being performed depending on this result, and
thus the cylindrical B-Spline model will be very
useful for us in working out functional parameters of
human hearts.
ACKNOWLEDGEMENTS
The testing image set was provided by Prof. G.
Yang’s research group at the Imperial College
London. This work was supported by the National
Natural Science Foundation of China
[NSFC-60405009, 60605013], [ZJNSF-Y105101,
Y104185], and a grant for Key Research Items from
the Dept of Science and Technology of Zhejiang
Province [2006C21002]. S. Y. Chen is a research
fellow of the Alexander von Humboldt Foundation,
Germany.
REFERENCES
A. F. Frangi, W. J. Niessen, M. A.Viergever, 2001.
Three-Dimensional Modeling for Functional Analysis
of Cardiac Images: A Review. IEEE transactions on
medical imaging, Vol.20.
J. O. Pentecost, J. Icardo, and K. L. Thornburg, 1999. 3D
computer modeling of human cardiogenesis.
Computerized Medical Imaging and Graphics.
K. Park, D. Metaxas, L. Axel, 2003. A Finite Element
Model for Functional Analysis of 4D Cardiac-Tagged
MR Images. Lecture Notes in Computer Science, vol.
p491-498.
Cristian Lorenz, Jens von Berg, 2006. A comprehensive
shape model of the heart, Medical Image Analysis.
C. Vuille and A. E. Weyman, 1994. Left ventricle I:
General considerations, assessment of chamber size
and function. in Principles and Practice of
Echocardiography, 2nd ed.
M. C. Dulce, G. H. Mostbeck, K. K. Friese, G. R. Caputo,
and C. B. Higgings, 1993. Quantification of the left
ventricular volumes and function with cine MR
imaging: Comparison of geometric models with three
dimensional data. Radiology, vol. 188, no. 2, pp.
371–376.
Jinah Park, Dimitri Metaxas, 1996. Deformable Models
with Parameter Functions for Cardiac Motion Analysis
from Tagged MRI Data. IEEE Trans. Medical
Imaging.,15(3): 278~289.
J. C. Cauvin, J. Y. Boire, M. Zanca, J. M. Bonny, J.
Maublant, and A. Veyre, 1993. 3D modeling in
myocardial 201TL SPECT. Computerized Medical
Imaging and Graphics, vol. 17, no. 4–5, pp. 345–350.
C. W. Chen, J. Luo, K. J. Parker, T. S. Huang, 1995. CT
volumetric data-based left ventricle motion estimation:
An integrated approach. Computerized Medical
Imaging and Graphics, vol. 19, no. 1, pp. 85–100.
L. H. Staib, J.S.Duncan, 1996. Model-based deformable
surface finding for medical images. IEEE Trans. Med.
Imag., vol. 15, pp. 720–731.
Idith Haber, Ron Kikinis and Carl-Fredrik Westin, 2001.
Phase-drive finite element model for spatio-temporal
tracking in cardiac tagged MRI. Springer-Verlag
Berlin Heidelberg.
Guo Luo and Pheng Ann Heng, 2004. LV Shape and
Motion: B-Spline Based Deformable Model and
Sequential Motion Decomposition IEEE Trans. Inf
Technol Biomed.
De Boor, 1978. A practical guide to splines. Springer.
Berlin
Farin, G.E., 2002. Curves and Surfaces for CAGD: A
Practical Guide. Kaufmann, San Francisco.
Farin, G.E., Dianne, H., 2000. The Essentials of CAGD.
Peters, Natick, USA.
Rogers, D.F., 2001. An Introduction to NURBS with
Historical. Perspective. Morgan Kaufmann, San
Francisco.
Ateshian, G.A., 1993. A B-Spline least-squares
surface-fitting method for articular surfaces of
diarthrodial joints. J. Biomech. Eng. 115, 366–373.
B.Zhang, J.F.M. Molenbroek, 2004. Representation of
human head with bi-cubic B-Spline technique based
on the laser scanning technique in 3D surface
anthropometry. Applied ergonomics, Elsevier.
Jon D. Klingensmith, D. Geoffrey Vince, 2002. B-Spline
methods for interactive segmentation and modeling of
lumen and vessel intravascular ultrasound.
Computerized Medical Imaging and Graphics.
Pergamon.
Nicholas J. Tustison, Victor G. Dávila-Román, and Amir
A. Amini. 2003. Myocardial Kinematics From Tagged
MRI Based on a 4-D B-Spline Model. IEEE Trans. on
BIOMEDICAL ENGINEERING, Vol. 50.
Amir A. Amini, Yasheng Chen, Mohamed Elayyadi, ,
Petia Radeva, 2001. Tag Surface Reconstruction and
Tracking of Myocardial Beads from SPAMM-MRI
with Parametric B-Spline Surfaces. IEEE Transactions
Medical Imaging.
William Paul Segars 2001. Development and application
of the new dynamic nurbs-based cardiac-torso (NCAT)
phantom. University of North Carolina, MA.
Xiang Deng and Thomas S. Denney, Jr. 2004.
Three-Dimensional Myocardial Strain Reconstruction
From Tagged MRI Using a Cylindrical B-Spline. IEEE
Trans. on MEDICAL IMAGING, Vol. 237.
Javier Sánchez-Reyes, 1995. Quasinonparametric surfaces.
Computer-Aided Design, Vol.27, p263 – 275.
Seok-Hyung Bae, Byoung K. Choi. 2002. NURBS surface
fitting using orthogonal coordinate transform for rapid
product development. Computer-Aided Design. vol. 34,
p683-690.
VISAPP 2007 - International Conference on Computer Vision Theory and Applications
68