Abstract

While the number of patients suffering from acute and chronic renal failure has been steadily increasing every year, the mortality rate is not improving. For the purpose of improvement on the quality of life and mortality of renal disease patients, we employ the hemofiltration principle to treat the end-stage renal disease patients. Hemofiltration equipment can be installed without additional plumbing and electrical power construction; operated only with several pre-packaged fluid bags without a huge water treatment facility. This paper describes the development of portable renal treatment equipment based on hemofiltration treatment, Carry-on Pulse Artificial Kidney (C-PAK), and reports the results of animal test using the equipment. The web-based remote monitor/control system for C-PAK is introduced also. We expect that our portable hemofiltration device for chronic renal failure patient would be an alternative for conventional hemodialysis machine and a solution to home renal treatment.

Download


Paper Citation


in Harvard Style

Chan Lee J., Eun Kim W., Moo Lim K., Chul Kim J. and Goo Min B. (2008). PERSONAL DIALYSIS USING A WEB-BASED, PORTABLE SYSTEM - C-PAK (Carry-on Pulse Artificial Kidney) . In Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 2: BIODEVICES, (BIOSTEC 2008) ISBN 978-989-8111- 17-3, pages 166-169. DOI: 10.5220/0001050701660169


in Bibtex Style

@conference{biodevices08,
author={Jung Chan Lee and Wook Eun Kim and Ki Moo Lim and Jeong Chul Kim and Byoung Goo Min},
title={PERSONAL DIALYSIS USING A WEB-BASED, PORTABLE SYSTEM - C-PAK (Carry-on Pulse Artificial Kidney)},
booktitle={Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 2: BIODEVICES, (BIOSTEC 2008)},
year={2008},
pages={166-169},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001050701660169},
isbn={978-989-8111- 17-3},
}


in EndNote Style

TY - CONF
JO - Proceedings of the First International Conference on Biomedical Electronics and Devices - Volume 2: BIODEVICES, (BIOSTEC 2008)
TI - PERSONAL DIALYSIS USING A WEB-BASED, PORTABLE SYSTEM - C-PAK (Carry-on Pulse Artificial Kidney)
SN - 978-989-8111- 17-3
AU - Chan Lee J.
AU - Eun Kim W.
AU - Moo Lim K.
AU - Chul Kim J.
AU - Goo Min B.
PY - 2008
SP - 166
EP - 169
DO - 10.5220/0001050701660169