INTERACTIVE RECONSTRUCTION AND VISUALIZATION OF DYNAMIC 3D ULTRASOUND DATA SETS
Timo Ropinski, Borislav Petkov, Larissa Fabritz, Klaus Hinrichs
2008
Abstract
In this paper we describe techniques which have been developed in order to interactively visualize dynamic 3D ultrasound (US) volume data sets acquired using a small animal 2D US scanner. The 2D frames are acquired at different spatial positions and gated based on the ECG signal. For the reconstruction process a user interface is specified, which allows the user to select 2D frames acquired during different ECG phases at different spatial locations. Thus it is possible to reconstruct and visualize a volumetric model based on several 2D frames for different phases of the heart cycle. To improve the interactive visualization, we facilitate filtering techniques, which have been implemented on the GPU.
References
- Fenster, A. and Downey, D. B. (2000). Three-dimensional ultrasound imaging. In Beutel, J., Kundel, H. L., and Metter, R. L. V., editors, SPIE Handbook on Medical Imaging - Volume I: Physics and Psychophysics. SPIE Press.
- Gee, A., Prager, R., Treece, G., and Berman, L. (2003). Engineering a freehand 3D ultrasound system. Pattern Recognition Letters, 24(4-5):757-777.
- Gee, A., Prager, R., Treece, G., Cash, C., and Berman, L. (2004). Processing and visualizing three-dimensional ultrasound data. British Journal of Radiology, 77(2):186-193.
- Gergs, U., Boknik, P., Buchwalow, I., Fabritz, L., Matus, M., Justus, I., Hanske, G., Schmitz, W., and Neumann, J. (2004). Overexpression of the catalytic subunit of protein phosphatase 2A impairs cardiac function. J. Biol. Chem., page M405770200.
- Gonzalez, R. C. and Woods, R. E. (2001). Digital Image Processing. Addison-Wesley Longman Publishing Co., Inc., Boston, MA, USA.
- Lung, N. H. and Institute, B. (2006). Ventricular septal defect. Online; accessed on 20-March-2007.
- Organization, W. H. (2006). Fact sheets: Cardiovascular diseases. Online; accessed on 23-March-2007.
- Sakas, G., Schreyer, L.-A., and Grimm, M. (1994). Case study: visualization of 3D ultrasonic data. In VIS 7894: Proceedings of the conference on Visualization 7894, pages 369-373, Los Alamitos, CA, USA. IEEE Computer Society Press.
- Sakas, G. and Walter, S. (1995). Extracting surfaces from fuzzy 3D-ultrasound data. In Computer Graphics Proceedings, Annual Conference Series SIGGRAPH 95, pages 465-474.
- VisualSonics (2005). Vevo 770 high-resolution imaging system: Operator manual.
Paper Citation
in Harvard Style
Ropinski T., Petkov B., Fabritz L. and Hinrichs K. (2008). INTERACTIVE RECONSTRUCTION AND VISUALIZATION OF DYNAMIC 3D ULTRASOUND DATA SETS . In Proceedings of the Third International Conference on Computer Graphics Theory and Applications - Volume 1: GRAPP, (VISIGRAPP 2008) ISBN 978-989-8111-20-3, pages 308-315. DOI: 10.5220/0001097003080315
in Bibtex Style
@conference{grapp08,
author={Timo Ropinski and Borislav Petkov and Larissa Fabritz and Klaus Hinrichs},
title={INTERACTIVE RECONSTRUCTION AND VISUALIZATION OF DYNAMIC 3D ULTRASOUND DATA SETS},
booktitle={Proceedings of the Third International Conference on Computer Graphics Theory and Applications - Volume 1: GRAPP, (VISIGRAPP 2008)},
year={2008},
pages={308-315},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001097003080315},
isbn={978-989-8111-20-3},
}
in EndNote Style
TY - CONF
JO - Proceedings of the Third International Conference on Computer Graphics Theory and Applications - Volume 1: GRAPP, (VISIGRAPP 2008)
TI - INTERACTIVE RECONSTRUCTION AND VISUALIZATION OF DYNAMIC 3D ULTRASOUND DATA SETS
SN - 978-989-8111-20-3
AU - Ropinski T.
AU - Petkov B.
AU - Fabritz L.
AU - Hinrichs K.
PY - 2008
SP - 308
EP - 315
DO - 10.5220/0001097003080315