SURFACE MODIFICATION OF DENTAL DEVICES - Surface Analysis of Plasma-based Fluorine and Silver Ion Implanted & Deposited Acrylic Resin

Yukari Shinonaga, Kenji Arita, Milanita E. Lucas

2009

Abstract

The aim of this study was to modify acrylic resin (PMMA) with fluorine (F) and silver (Ag) dual ions by a hybrid process of plasma-based ion implantation & deposition (PBII-D), and to enable the surface of the devices inhibition of bacterial adhesion. The surface characteristics, hydrophobic property and brushing abrasion resistance were evaluated by XPS analysis, contact angle measurement and brushing abrasion test. F and Ag were implanted-deposited and have formed carbon-fluoride and Ag-deposited layer on the surface of the PMMA plate. The contact angle of F+Ag implanted-deposited PMMA was increased compared with non-treated control and F only deposited PMMA. After 60,000 brushing strokes, the contact angle of modified PMMA remained to be higher than that of the control PMMA. This study indicated that F+Ag implantation-deposition has improved the hydrophobic property of acrylic resin and was sustained even after routine tooth brushing.

References

  1. Briggs, D., Seah, MP., 1990. Practical surface analysis 2nd edition., Volume 1 Auger and X-ray Photoelectron spectroscopy, 595-634.
  2. Busscher, HJ., Weerkamp, AH., Mei, HC., Pelt, AWJ., Jong, HP., 1984. Appl. Environ. Microbiol. 980-983.
  3. Conrad, JR., Radtke, JL., Worzala, FJ., 1987. J. Appl. Phys. 62, 4591-4596.
  4. Grastina, A. G., 1987. Science.237, 1588-1595.
  5. Kanter, J., Koski, RE., Martin, D., 1982. J. Prosthet. Dent., 47, 505-513.
  6. Kuze, E., Teramoto, T., Yukimura, K., Maruyama, T., 2002. Surf. Coat. Technol, 577-581.
  7. Liu, Y., Zhao, Q., 2005. Biophys. Chem. 39-45.
  8. Nurhaerani., Arita, K., Shinonaga, Y., Nishino, M., 2007. Dent.Mater. J, 684-692.
  9. Perini, CI., Zhao, Q., Liu, Y., Abel, E., 2006. Colloids. Surf. B: Biointerfaces., 143-147.
  10. Sumi, Y., Miura, H., Michiwaki, Y., Nagaosa, S., Nagaya, M., 2007.. Arch. Gerontol. Geriatr. 44, 119-124.
  11. Zhao, Q., Liu, Y., Wang, C., Wang, S., Peng, N., Jeynes, C., 2007. Appl. Surf. Sci, 8674-8681.
Download


Paper Citation


in Harvard Style

Shinonaga Y., Arita K. and E. Lucas M. (2009). SURFACE MODIFICATION OF DENTAL DEVICES - Surface Analysis of Plasma-based Fluorine and Silver Ion Implanted & Deposited Acrylic Resin . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 157-160. DOI: 10.5220/0001424101570160


in Bibtex Style

@conference{biodevices09,
author={Yukari Shinonaga and Kenji Arita and Milanita E. Lucas},
title={SURFACE MODIFICATION OF DENTAL DEVICES - Surface Analysis of Plasma-based Fluorine and Silver Ion Implanted & Deposited Acrylic Resin},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={157-160},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001424101570160},
isbn={978-989-8111- 64-7},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - SURFACE MODIFICATION OF DENTAL DEVICES - Surface Analysis of Plasma-based Fluorine and Silver Ion Implanted & Deposited Acrylic Resin
SN - 978-989-8111- 64-7
AU - Shinonaga Y.
AU - Arita K.
AU - E. Lucas M.
PY - 2009
SP - 157
EP - 160
DO - 10.5220/0001424101570160