DEVICE FOR SYNCHRONIZED ROTATION
Shuh Jing Ying, Rufael Berhane, Rajiv Dubey
2009
Abstract
This device makes two shafts rotating in synchronized angular displacement. The sensors are potentiometers. The device is designed for use in a driving simulator. The first shaft is connected to a steering wheel and controlled by a driver so this shaft is the master, the second shaft is connected to the computer software that displays the surrounding sceneries, therefore this shaft is the follower. The two shafts must be rotated in synchronized mode and accurately. Major components in this device are operational amplifiers, NAND gates, power MOFET and relays. Details in design and manufacturing are reported in this paper. This device may be used for any place that requires two shafts rotating synchronically.
References
- Narsingh Deo, 1983, System Simulation with Digital Computer, Prentice-Hall Englewood Cliffs, N. J.
- Geert Van der Plas, Georges Gielen and Willy Sansen, 2002, A computer-aided design and synthesis for Analog Integrated Circuits, Kluwer Academic Publishers, Boston, MA.
- Amplifier Reference Manual, 1992, Analog Devices Norwood, MA.
- The ARRL Handbook for radio 2006, 2005 83rd Edition A. R. R. L.
- Ying, Shuh Jing, Patti Barrett, and Stephen Sundarrao, 2008, A Device Turning on Strobe Light from Horn Signal, BMES Annual Fall Meeting, St.Louis, MO Ying, Shuh Jing and Stephen Sundarrao, 2007 Design and Manufacturing of A Wheel Chair Treadmill, RESNA 2007
- DC Supply voltage………….……..........…….18 V Input voltage…….……………………….…18.5 V Output Voltage….…………………………..18.5 V DC input current……….……………..……..10 mA Power dissipation…………………..……... 300 mW Operation Temperature range………...... -40 to 85oC Storage Temperature range…………… -65 to 150oC IRFP250N-SPECIFICATIONS Maximum Ratings:
Paper Citation
in Harvard Style
Ying S., Berhane R. and Dubey R. (2009). DEVICE FOR SYNCHRONIZED ROTATION . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 339-342. DOI: 10.5220/0001431903390342
in Bibtex Style
@conference{biodevices09,
author={Shuh Jing Ying and Rufael Berhane and Rajiv Dubey},
title={DEVICE FOR SYNCHRONIZED ROTATION},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={339-342},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001431903390342},
isbn={978-989-8111- 64-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - DEVICE FOR SYNCHRONIZED ROTATION
SN - 978-989-8111- 64-7
AU - Ying S.
AU - Berhane R.
AU - Dubey R.
PY - 2009
SP - 339
EP - 342
DO - 10.5220/0001431903390342