DEVELOPMENT OF STRATHCLYDE UNIVERSITY DATA LOGGING SYSTEM (SUDALS) FOR USE WITH FLEXIBLE ELECTROGONIOMETERS
Vivek Padmanaabhan Indra Mohan, G. Valsan, P. J. Rowe
2009
Abstract
We have developed a 6 channel battery operated remote control microprocessor based system that collects data from flexible electrogoniometers and force sensing resistors attached to the lower extremities of the body. During functional activities, the user-friendly system stores the data from these transducers and transfers the same to a PC at the end of the recording period via a bluetooth connection. Software on the PC then displays the angular displacement and allows visual inspection of the entire sequence of recordings or particular events of interest. This system was tested on 10 normal subjects and the pattern pertaining to the flexion/extension of knee during range of activities of daily living (ADL) such as walking, ascending and descending stairs, in and out of a chair and deep squatting were recorded and found to be reproducible and similar to those reported in the literature.
References
- Andriacchi.T.P. et al, vol 62-A, no: 5, 749-757, 1980. A study of lower-limb mechanics during stair climbing, Journal of bone and joint surgery.
- Costigan.P.A et al, vol16, 31-37, 2001. Knee and hip kinetics during normal stair climbing. Journal of Gait and posture
- Huddleston.J et al, 3:21, 2006. Ambulatory measurement of knee motion and physical activity: preliminary evaluation of a smart activity monitor. Journal of neuroengineering and rehabilitation
- Jevsevar.D.S et al, vol73, no: 4, 1993. Knee kinematics and kinetics during locomotor activities of daily living in subjects with knee arthroplasty and in healthy control subjects. Journal of physical therapy
- Kettlekamp et al, vol 52, 775-790, 1970. An electrogoniometric study of knee motion in normal gait. Journal of bone and joint surgery
- Lark S.D et al, vol 91, 287-295, 2004. Knee and ankle range of motion during stepping down in elderly compared to young men. European journal of applied physiology
- Protopapadakki.A. et al, vol22, 203-210, 2007, Hip, Knee, ankle kinematics and kinetics during stair ascent and descent in healthy young individuals, Clinical Biomechanics.
- Rowe P.J et al, vol 87, no: 9, 479 - 487, 2001. Validation of FEG as a measure of joint kinematics. Journal of Physiotherapy
- Rowe P.J et al, vol13, no: 2, 131-138, 2005.The effect of TKA on joint movement during functional activities and joint range of motion with particular regard to higher flexion users. Journal of Orthopedic surgery
- Wyss.U et al, 2003, High range of motion activities of daily living: Differences in the kinematics between Hong Kong and Chennai, India Subjects. ISB XXth Congress - ASB 29th Annual Meeting, Ohio
- Zhu.H et al, vol 38, No: 7, July 1991.A MicroprocessorBased Data acquisition system for measuring plantar pressures from ambulatory subjects. IEEE TRANSACTIONS ON Biomedical Engineering
- Zhang.Z&Liu.P, 2004. Application of bluetooth technology in ambulatory wireless medical monitoring. 4th international conference on microwave and millimeter wave technology proceedings
Paper Citation
in Harvard Style
Padmanaabhan Indra Mohan V., Valsan G. and J. Rowe P. (2009). DEVELOPMENT OF STRATHCLYDE UNIVERSITY DATA LOGGING SYSTEM (SUDALS) FOR USE WITH FLEXIBLE ELECTROGONIOMETERS . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 198-203. DOI: 10.5220/0001533301980203
in Bibtex Style
@conference{biodevices09,
author={Vivek Padmanaabhan Indra Mohan and G. Valsan and P. J. Rowe},
title={DEVELOPMENT OF STRATHCLYDE UNIVERSITY DATA LOGGING SYSTEM (SUDALS) FOR USE WITH FLEXIBLE ELECTROGONIOMETERS },
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={198-203},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001533301980203},
isbn={978-989-8111- 64-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - DEVELOPMENT OF STRATHCLYDE UNIVERSITY DATA LOGGING SYSTEM (SUDALS) FOR USE WITH FLEXIBLE ELECTROGONIOMETERS
SN - 978-989-8111- 64-7
AU - Padmanaabhan Indra Mohan V.
AU - Valsan G.
AU - J. Rowe P.
PY - 2009
SP - 198
EP - 203
DO - 10.5220/0001533301980203