CORRECTION OF ACOUSTIC LENS ERROR IN SPATIAL COMPOUNDING OF ULTRASONIC DIAGNOSTIC IMAGES
Myoung H. Choi
2009
Abstract
Spatial compounding has been used in ultrasonic imaging for suppressing speckle noise. The technique generally involves electronically steering the ultrasonic beams. The steering angle of the ultrasonic beam is distorted by the acoustic lens structure of the probe that is used to focus the beam mechanically. These errors introduced by the lens structure cause misalignment of the ultrasonic images received at different steering angles, and consequently results in the blurred image after spatial compounding. In this paper, a solution is proposed that corrects the lens error by using image registration. The lens error was compensated by registering the wire target images before spatial compounding. An efficient registration algorithm was developed to compute the transformation matrix required for the registration. The images were registered by the transformation matrix before spatial compounding.
References
- C. B. Burckhardt, 1978. “Speckle in ultrasound B scans,” IEEE Trans. Sonics Ultrason., SU-25, 1-6.
- J. G. Ahbott and F. L. Thurstone, 1979. “Acoustic speckle: Theory and experimental analysis,” Ultrason. Imaging, 1, 303-324.
- P. N. T. Wells and M. Halliwell, 1981. “Speckle in ultrasonic imaging,” Ultrason., 19, 225-229,.
- R. F. Wagner. S. W. Smith, J. M. Sandrik and H. Lopez, 1983. “Statistics of speckle in ultrasound B scans,” IEEE Trans. Sonics Ultrason., SU-30, 156-163,.
- D. P. Shattuck and O. T. von Ramm, 1982. “Compound scanning with a phased array,” Ultrason. Imaging, 4(2), 93-107.
- M. O'Donnell and S. D. Silverstein, 1988. “Optimum displacement for compound image generation in medical ultrasound,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., 35(4), 470-476.
- S. D. Silverstein and M. O'Donnell, 1987. “Speckle reduction using correlated mixed-integration techniques,” in Proc. SPIE 768 Pattern Recognition and Acoust. Imaging, 168-172.
- G. E. Trahey, S. W. Smith, and O. T. von Ramm, 1986. “Speckle pattern correlation with lateral aperture translation: Experimental results and implications for spatial compounding,” IEEE Trans. Ultrason., Ferroelect., Freq. Contr., 33(3), 257-264.
- P. M. Shankar, 1986. "Speckle Reduction in Ultrasound B-Scans Using Weighted Averaging in Spatial Compounding", IEEE Trans. On Ultrasonics, Ferroelectrics, and Frequency Control, Vol. UFFC-33(6).
- R. R. Entrekin, B. A. Porter, H. H. Sillesen, A. D. Wong, P. L. Cooperberg, and C. H. Fix, 2001. “Real-time spatial compound imaging: Application to breast, vascular, and musculoskeletal ultrasound,” Semin. Ultrasound CT MR, 22(1), 50-64.
- S. Huber, M. Wagner, M. Medl, and H. Czembirek, 2002. “Real-time spatial compound imaging in breast ultrasound,” Ultrasound Med. Biol., 28(2), 155-163.
- J. F. Krücker, G. L. LeCarpentier, J. B. Fowlkes, and P. L. Carson, 2002. “Rapid elastic image registration for 3- D ultrasound,” IEEE Trans. Med. Imag., 21(11), 1384-1394.
- J.-Y. Meuwly, J.-P. Thiran, and F. Gudinchet, 2003. “Application of adaptive image processing technique to real-time spatial compound ultrasound imaging improves image quality,” Invest. Radiol., 38(5), 257-262.
- Wilhjelm, J. E., Jensen M. S., Jespersen S.K., Sahl B., Falk E. 2004. "Visual and Quantitative Evaluation of Selected Image Combination Schemes in Ultrasound Spatial Compound Scanning," IEEE Trans. on Medical Imaging, 23(2), 181-190.
- Fu, Gonzales, and Lee, 1987. Robotics: Control, Sensing, Vision and Intelligence, McGraw-Hill.
Paper Citation
in Harvard Style
Choi M. (2009). CORRECTION OF ACOUSTIC LENS ERROR IN SPATIAL COMPOUNDING OF ULTRASONIC DIAGNOSTIC IMAGES . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 235-238. DOI: 10.5220/0001548302350238
in Bibtex Style
@conference{biodevices09,
author={Myoung H. Choi},
title={CORRECTION OF ACOUSTIC LENS ERROR IN SPATIAL COMPOUNDING OF ULTRASONIC DIAGNOSTIC IMAGES},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={235-238},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001548302350238},
isbn={978-989-8111- 64-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - CORRECTION OF ACOUSTIC LENS ERROR IN SPATIAL COMPOUNDING OF ULTRASONIC DIAGNOSTIC IMAGES
SN - 978-989-8111- 64-7
AU - Choi M.
PY - 2009
SP - 235
EP - 238
DO - 10.5220/0001548302350238