Abstract

The auricular electrical punctual stimulation is usually applied for pain relief. The common application involves fixed stimulation parameters, which makes the simulation insensitive to prevailing pain or stress level and may lead to a disadvantageous over-stimulation. In order to address this issue, the given position paper presents an experimental background leading to a conceptual design of an adaptive and synchronized stimulation technique. Here parameters of the heart rate variability are used as stimulation biofeedback, while the stimulating signal is synchronized with cardiac or respiratory activity to boost stimulation effects.

References

  1. Gao, X.Y., Zhang S.P., Zhu, B., Zhang H.Q., 2008. Investigation of specificity of auricular acupuncture points in regulation of autonomic function in anesthetized rats. Autonomic Neuroscience: Basic and Clinical, 138, 50-56.
  2. Gbaoui, L., Kaniusas, E., Szeles, J.C., Materna, T., Varoneckas, G., 2008a. Heart rate variability during electrostimulation on ear: spectral domain versus state space (in german). Proceedings of XXII Symposium on Measuring Technique, 230-238.
  3. Gbaoui, L., Kaniusas, E., Szeles, J.C., Materna, T., Varoneckas, G., 2008b. Effects of the auricular electrical stimulation on heart rate variability assessed in phase space: pilot study. Accepted for IEEE Sensors 2008 in Lecce, Italy.
  4. Haker, E., Egekvist, H., Bjerring, P., 2000. Effect of sensory stimulation (acupuncture) on sympathetic and parasympathetic activities in healthy subjects. Journal of the Autonomic Nervous System, 79, 52-59.
  5. Kaniusas, E., Gbaoui, L., Szeles, J.C., Materna, T., Varoneckas, G., 2008. Validation of auricular electrostimulation by heart rate variability and blood perfusion: possibilities and restrictions. Proceedings of Microelectronics Conference 2008, 180-184.
  6. Kaniusas, E., Pfützner, H. et al., 2004. Magnetoelastic skin curvature sensor for biomedical applications. Proceedings of IEEE Sensors, 1484-1487.
  7. Likar, R., Jabarzadeh, H. et al., 2007. Auricular electrical punctual stimulation (P-STIM): a randomized, doubleblind, controlled pilot study in laparoscopic nephrectomy (in german). Schmerz, 21(2), 154-159.
  8. Litscher, G., Wang, L., Gaischek, I., 2007. Electroencephalographic responses to laserneedle and punctual stimulation quantified by bispectral (BIS) monitoring: a pilot study to evaluate methods and instrumentation. Internet Journal of Laserneedle Medicine, 1(1).
  9. Peuker, E.T., Filler, T.J., 2002. The nerve supply of the human auricle. Clinical Anatomy, 15, 35-37.
  10. Pfützner, H., Kaniusas, E. et al., 2006. Magnetostrictive bilayers for multi-functional sensor families. Sensors and Actuators A: Physical, 129, 154-158.
  11. Sator-Katzenschlager, S.M., Scharbert, G. et al., 2004. The short and long term benefit in chronic low back pain through adjuvant electrical versus manual auricular acupuncture. Anesthesia & Analgesia, 98, 1359-1364.
  12. Sator-Katzenschlager, S.M., Wölfler, M.M. et al., 2006. Auricular electro-acupuncture as an additional perioperative analgesic method during oocyte aspiration in IVF treatment. Human reproduction, 21(8), 2114-2120.
  13. Szeles, J.C., 2001a. Therapy appliance for punctual stimulation. Patents WO 01/35897, US7336993.
  14. Szeles, J.C., Hoda, M.R., Polterauer, P, 2001b. Application of electrostimulation acupuncture (P-Stim) in clinical practice. Schmerznachrichten from Austrian Pain Association, 1.
  15. Szeles, J.C., Litscher, G., 2004. Objectivation of cerebral effects with a new continuous electrical auricular stimulation technique for pain management. Neurological Research, 26(7), 797-800.
  16. Guidelines, 1996. Heart rate variability: standards of measurement, physiological interpretation, and clinical use. Circulation, 93(5), 1043-1065.
Download


Paper Citation


in Harvard Style

Kaniusas E., Szeles J., Materna T. and Varoneckas G. (2009). ADAPTIVE AURICULAR ELECTRICAL STIMULATION CONTROLLED BY VITAL BIOSIGNALS - Transition from Fixed to Adaptive and Synchronized Electrical Stimulation Controlled by Heart Rate Variability and Blood Perf . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 304-309. DOI: 10.5220/0001779703040309


in Bibtex Style

@conference{biodevices09,
author={Eugenijus Kaniusas and Jozsef Constantin Szeles and Tilo Materna and Giedrius Varoneckas},
title={ADAPTIVE AURICULAR ELECTRICAL STIMULATION CONTROLLED BY VITAL BIOSIGNALS - Transition from Fixed to Adaptive and Synchronized Electrical Stimulation Controlled by Heart Rate Variability and Blood Perf},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={304-309},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001779703040309},
isbn={978-989-8111- 64-7},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - ADAPTIVE AURICULAR ELECTRICAL STIMULATION CONTROLLED BY VITAL BIOSIGNALS - Transition from Fixed to Adaptive and Synchronized Electrical Stimulation Controlled by Heart Rate Variability and Blood Perf
SN - 978-989-8111- 64-7
AU - Kaniusas E.
AU - Szeles J.
AU - Materna T.
AU - Varoneckas G.
PY - 2009
SP - 304
EP - 309
DO - 10.5220/0001779703040309