WAVELET SAMPLE ENTROPY OPTIMIZATION THROUGH OPTIMAL MOTHER FUNCTION SELECTION FOR ATRIAL FIBRILLATION ANALYSIS

Raúl Alcaraz, José Joaquín Rieta

2010

Abstract

Wavelet Sample Entropy (WSE) has been previously introduced as a successful methodology to predict electrical cardioversion (ECV) outcome of persistent atrial fibrillation (AF). The method estimates AF organization based on the combination of Wavelet decomposition and non-linear regularity metrics, such as Sample Entropy (SampEn). However, WSE has been only computed by applying a specific wavelet function, such as the fourth-order biorthogonal wavelet. In the present work, with the objective of improving WSE robustness and its diagnostic ability in ECV outcome prediction, several orthogonal wavelet families were tested, and their performances were compared. Results indicated that, for all the functions of the same wavelet family, the same sensitivity and specificity were obtained. Additionally, all the wavelet families reached the same diagnostic ability (80.95% sensitivity and 85.71% specificity), being the same patients incorrectly classified by all the families. These results suggest that any wavelet family could be indistinctly used to estimate successfully AF organization with the WSE methodology. As a consequence, the design of a customized wavelet function adapted to the specific characteristics of AA would not improve the WSE diagnostic ability in the prediction of ECV outcome in AF.

References

  1. Addison, P. S. (2005). Wavelet transforms and the ECG: a review. Physiol Meas, 26(5):R155-R199.
  2. Alcaraz, R. and Rieta, J. J. (2007). Adaptive singular value QRST cancellation for the analysis of short single lead atrial fibrillation electrocardiograms. Proc. Comput. Cardiol., 34:513-516.
  3. Alcaraz, R. and Rieta, J. J. (2008). Predicting electrical cardioversion outcome from surface ecg recordings through Wavelet Sample Entropy. Conf Proc IEEE Comput Cardiol, pages 1041-1044.
  4. Bollmann, A., Husser, D., Mainardi, L., Lombardi, F., Langley, P., Murray, A., Rieta, J. J., Millet, J., Olsson, S. B., Stridh, M., and S örnmo, L. (2006). Analysis of surface electrocardiograms in atrial fibrillation: techniques, research, and clinical applications. Europace, 8(11):911-926.
  5. Dotsinsky, I. and Stoyanov, T. (2004). Optimization of bi-directional digital filtering for drift suppression in electrocardiogram signals. J Med Eng Technol, 28(4):178-180.
  6. Ferdjallah, M. and Barr, R. E. (1994). Adaptive digital notch filter design on the unit circle for the removal of powerline noise from biomedical signals. IEEE Trans Biomed Eng, 41(6):529-536.
  7. Gall, N. P. and Murgatroyd, F. D. (2007). Electrical cardioversion for AF-the state of the art. Pacing Clin Electrophysiol, 30(4):554-567.
  8. Petrutiu, S., Ng, J., Nijm, G. M., Al-Angari, H., Swiryn, S., and Sahakian, A. V. (2006). Atrial fibrillation and waveform characterization. A time domain perspective in the surface ECG. IEEE Eng Med Biol Mag, 25(6):24-30.
  9. Sun, Y., Chan, K., and Krishnan, S. M. (2002). ECG signal conditioning by morphological filtering. Comput Biol Med, 32(6):465-479.
  10. Tieleman, R. G., Gelder, I. C. V., Crijns, H. J., Kam, P. J. D., Berg, M. P. V. D., Haaksma, J., Woude, H. J. V. D., and Allessie, M. A. (1998). Early recurrences of atrial fibrillation after electrical cardioversion: a result of fibrillation-induced electrical remodeling of the atria? J Am Coll Cardiol, 31(1):167-173.
Download


Paper Citation


in Harvard Style

Alcaraz R. and Joaquín Rieta J. (2010). WAVELET SAMPLE ENTROPY OPTIMIZATION THROUGH OPTIMAL MOTHER FUNCTION SELECTION FOR ATRIAL FIBRILLATION ANALYSIS . In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 389-392. DOI: 10.5220/0002692003890392


in Bibtex Style

@conference{biosignals10,
author={Raúl Alcaraz and José Joaquín Rieta},
title={WAVELET SAMPLE ENTROPY OPTIMIZATION THROUGH OPTIMAL MOTHER FUNCTION SELECTION FOR ATRIAL FIBRILLATION ANALYSIS},
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={389-392},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002692003890392},
isbn={978-989-674-018-4},
}


in EndNote Style

TY - CONF
JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - WAVELET SAMPLE ENTROPY OPTIMIZATION THROUGH OPTIMAL MOTHER FUNCTION SELECTION FOR ATRIAL FIBRILLATION ANALYSIS
SN - 978-989-674-018-4
AU - Alcaraz R.
AU - Joaquín Rieta J.
PY - 2010
SP - 389
EP - 392
DO - 10.5220/0002692003890392