RESPIRATORY INFORMATION IN ARTERIAL OXYGEN SATURATION MEASUREMENT
Yue-Der Lin
2010
Abstract
Pulse oximeter has become a standard in intensive and critical care units for the monitoring of oxygen support from respiratory system since 1990’s. The multi-wavelength photoplethysmography (PPG) technique is now utilized for the measurement of arterial oxygen saturation by pulse oximeter (SpO2). This research utilized multi-channel autoregressive (AR) spectral estimation method for the coherence analysis between the respiratory signal and the PPG signal derived from pulse oximeter. Five healthy male subjects participated in this research with signals being measured at different respiratory status. The results demonstrate high coherence between respiration and the PPG signal from pulse oximeter, and the coherence disappears in breath-holding experiments. The results demonstrate that the respiratory status can also be acquired from the measurement of arterial oxygen saturation. This implies the possibility to acquire the physiological parameters other than arterial oxygen saturation form pulse oximeters.
References
- Hertzman, A. B. and Spielman, C. R., 1937, Observations on the finger volume pulse recorded photoelectrically. In Am. J. Physiol., vol.119, pp.334-335.
- Johansson, A., Öberg, P. Å. and Sedin, G., 1999, Monitoring of heart and respiratory rates in newborn infants using a new photoplethysmographic technique. In J. Clin. Monit., vol.15, pp.461-467.
- Johansson, A. and Öberg, P. Å., 1999a, Estimation of respiratory volumes from the photoplethysmographic signal. Part I: experimental results. In Med. Biol. Eng. Comput., vol.37, pp.42-47.
- Johansson, A. and Öberg, P. Å., 1999b, Estimation of respiratory volumes from the photoplethysmographic signal. Part II: a model study. In Med. Biol. Eng. Comput., vol.37, pp.48-53.
- Levinson, N., 1947, The Wiener RMS (root mean square) error criterion in filter design and prediction. In J. Math. Phys., vol.25, pp.261-278.
- Morf, M., Vieira, A., Lee, D. T. and Kailath, T., 1978, Recursive multichannel maximum entropy spectral estimation. In IEEE Trans. Geosci. Electron., vol.16, pp.85-94.
- Nilsson, L., Johansson, A. and Kalman, S., 2000, Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique. In J. Clin. Monit., vol.16, pp.309-315.
- Nilsson, L., Johansson, A. and Kalman, S., 2003, Macrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal. In Physiol. Meas., vol.24, pp.925- 937.
- Webster, J. G. Ed., 1997, Design of Pulse Oximeters, IOP Publishing, Bristol.
- Welch, P. D., 1970, The use of the fast Fourier transform for the estimation of power spectra. In IEEE Trans. Audio Electroacoust., vol.AU-15, pp.70-73.
Paper Citation
in Harvard Style
Lin Y. (2010). RESPIRATORY INFORMATION IN ARTERIAL OXYGEN SATURATION MEASUREMENT . In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 168-173. DOI: 10.5220/0002693501680173
in Bibtex Style
@conference{biosignals10,
author={Yue-Der Lin},
title={RESPIRATORY INFORMATION IN ARTERIAL OXYGEN SATURATION MEASUREMENT},
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={168-173},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002693501680173},
isbn={978-989-674-018-4},
}
in EndNote Style
TY - CONF
JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - RESPIRATORY INFORMATION IN ARTERIAL OXYGEN SATURATION MEASUREMENT
SN - 978-989-674-018-4
AU - Lin Y.
PY - 2010
SP - 168
EP - 173
DO - 10.5220/0002693501680173