MECHANOMYOGRAPHIC ANALYSIS WITH 0.2 S AND 1.0 S TIME DELAY AFTER ONSET OF CONTRACTION
Eddy Krueger, Eduardo M. Scheeren, Gean Francesco D. Chu, Percy Nohama, Guilherme N. Nogueira-Neto, Vera Lúcia S. Nantes Button
2010
Abstract
Muscle contractions generate lateral oscillations and motion artifacts that can be detected by MMG sensors placed in the inner and outer sides of the forearm. These artifacts can significantly affect signal processing and eventually it is necessary to eliminate their influence in order to detect movements reliably. One approach is to respect a time delay after the onset of contraction. This study aimed to evaluate the correlation of 0.2 s and 1.0 s time delays after the onset of contraction during wrist movements. This work respected two different time delays before initiating the signal analysis. Two analysis window lengths were evaluated (0.25 s and 0.50 s). The results showed that there are strong correlations between the acquired signals with both time delays, mainly the devised RZ feature (0.81–0.95). This study was a first approach to determine whether triaxial MMG features can be used for motor prosthesis control. The axial moduli presented strong correlations for all movements and can be productive in future applications.
References
- Alves, N. & Chau, T. (2008) Stationarity distributions of mechanomyogram signals from isometric contractions of extrinsic hand muscles during functional grasping. Journal of Electromyography and Kinesiology, 18, 509-515.
- Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W. & Malek, M. H. (2004) Mechanomyographic and electromyographic time and frequency domain responses during submaximal to maximal isokinetic muscle actions of the biceps brachii. European Journal of Applied Physiology, 92, 352-9.
- Cipriano, J. J. (2003) Photographic manual of regional orthopaedic and neurological tests, Atlanta, Georgia, Lippincott Williams & Wilkins.
- Englehart, K. & Hudgins, B. (2003) A robust, real-time control scheme for multifunction myoelectric control. IEEE Transactions on Biomedical Engineering 50, 848-854.
- Nogueira-Neto, G. N., Müller, R. W., Salles, F. A., Nohama, P. & Button, V. L. S. (2008) Mechanomyographic sensor: a triaxial accelerometry approach. BIOSTEC. Funchal, Madeira - Portugal.
- Nolan, Y. & Depaor, A. (2004) The mechanomyogram as a channel of communication and control for the disabled. International Conference of the IEEE EMBS. 26 ed. San Francisco.
- Petitjean, M., Maton, B. & Fourment, A. (1998) Summation of elementary phonomyograms during isometric twitches in humans. European Journal of Applied Physiology, 77, 527-35.
- Prociow, P., Wolczowski, A., Amaral, T., Dias, O. & Filipe, J. (2008) Identification of hand movements based on MMG and EMG signals. BIOSTEC. Funchal, Madeira - Portugal.
- Silva, J. & Chau, T. (2003) Coupled microphoneaccelerometer sensor pair for dynamic noise reduction in MMG signal recording. Electronics Letters, 39, 1496-8.
- Smith, D. B., Housh, T. J., Johnson, G. O., Evetovich, T. K., Ebersole, K. T. & Perry, S. R. (1998) Mechanomyographic and electromyographic responses to eccentric and concentric isokinetic muscle actions of the biceps brachii. Muscle & nerve, 21.
- Wojtczak, P., Amaral, T. G., Dias, O. P., Wolczowski, A. & Kurzynski, M. (2009) Hand movement recognition based on biosignal analysis. Engineering Applications of Artificial Intelligence, 22, 608-615.
Paper Citation
in Harvard Style
Krueger E., M. Scheeren E., Francesco D. Chu G., Nohama P., N. Nogueira-Neto G. and Lúcia S. Nantes Button V. (2010). MECHANOMYOGRAPHIC ANALYSIS WITH 0.2 S AND 1.0 S TIME DELAY AFTER ONSET OF CONTRACTION . In Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010) ISBN 978-989-674-018-4, pages 296-299. DOI: 10.5220/0002746902960299
in Bibtex Style
@conference{biosignals10,
author={Eddy Krueger and Eduardo M. Scheeren and Gean Francesco D. Chu and Percy Nohama and Guilherme N. Nogueira-Neto and Vera Lúcia S. Nantes Button},
title={MECHANOMYOGRAPHIC ANALYSIS WITH 0.2 S AND 1.0 S TIME DELAY AFTER ONSET OF CONTRACTION },
booktitle={Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)},
year={2010},
pages={296-299},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0002746902960299},
isbn={978-989-674-018-4},
}
in EndNote Style
TY - CONF
JO - Proceedings of the Third International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2010)
TI - MECHANOMYOGRAPHIC ANALYSIS WITH 0.2 S AND 1.0 S TIME DELAY AFTER ONSET OF CONTRACTION
SN - 978-989-674-018-4
AU - Krueger E.
AU - M. Scheeren E.
AU - Francesco D. Chu G.
AU - Nohama P.
AU - N. Nogueira-Neto G.
AU - Lúcia S. Nantes Button V.
PY - 2010
SP - 296
EP - 299
DO - 10.5220/0002746902960299