BIORESPONSE TO STEREOSCOPIC MOVIES PRESENTED VIA A HEAD-MOUNTED DISPLAY
Takada Hiroki, Matsuura Yasuyuki, Fujikake Kazuhiro, Miyao Masaru
2011
Abstract
Three-dimensional (3-D) television sets are already available in the market and are becoming increasingly popular among consumers. The 3-D movies they play, however, induce the negative sensations of asthenopia and motion sickness in some viewers. Visually induced motion sickness (VIMS) is caused by sensory conflict, i.e., a disagreement between vergence and visual accommodation during the viewing of stereoscopic images. VIMS can be analyzed both subjectively and physiologically. The objective of this study is to develop a method for detecting VIMS. We quantitatively measured head acceleration and body sway during viewer exposure to both a two-dimensional (2-D) image and a conventional three-dimensional (3-D) movie. The subjects wore head-mounted displays (HMDs) and maintained the Romberg posture for the first 60 s and a wide stance (midlines of the heels 20 cm apart) for the next 60 s. Head acceleration was measured using an active tracer at a sampling frequency of 50 Hz. Subjects completed the Simulator Sickness Questionnaire (SSQ) immediately afterwards. Statistical analysis was then applied to the SSQ subscores and to each index of stabilograms. Transfer function analysis indicated that the acceleration of the head in the anterior-posterior direction while watching a 3-D movie can affect lateral body sway, thereby causing VIMS.
References
- Collins, J. J., De Luca, C. J., (1993) Open-loop and closed-loop control of posture: A random-walk analysis of center of pressure trajectories, Exp. Brain Res., 95, 308-318.
- Emmerrik, R. E. A., Van Sprague, R. L., Newell, K. M., (1993). Assessment of sway dynamics in tardive dyskinesia and developmental disability: sway profile orientation and stereotypy, Movement Disorders, 8, 305-314.
- Goldie, P., A., Bach, T., M., Evans, O., M., (1989). Force platform measures for evaluating postural control: reliability and validity, Arch. Phys. Med. Rehabi., 70, 510-517.
- Holomes, S. R., Griffin, M. J., (2001). Correlation between heart rate and the severity of motion sickness caused by optokinetic stimulation, J. Psychophysiology, 15, 35-42.
- Kennedy, R. S., Lane, N. E., Berbaum, K. S., Lilienthal, M. G., (1993). A simulator sickness questionnaire (SSQ): A new method for quantifying simulator sickness, International J Aviation Psychology, 3, 203- 220.
- Matsumoto, T., Tokunaga, R., Miyano, T., Tokuda, I., (2002). Chaos and Time Series. Tokyo: Baihukan Okawa, T., Tokita, T., Shibata, Y., Ogawa, T., Miyata, H., (1996). Stabilometry-Significance of locus length per unit area (L/A). Equilibrium Res., 54(3), 296-306.
- Reason, J., (1978). Motion sickness adaptation: A Neural mismatch model. J. Royal Soc. Med., 71, 819-829.
- Sakaguchi, M., Taguchi, K., Ixhiyama, T., Netsu, K., Sato, K., (1995). Relationship between head sway and center of foot pressure sway, Auris Nasus Larynx, 22(3), 151-157.
- Scibora, L. M., Villard, S., Bardy, B., Stoffregen, T. A., (2007). Wider stance reduces body sway and motion sickness. Proc. VIMS 2007, 18-23.
- Stoffregen, T. A., Smart, L. J., Bardy, B. J., Pagulayan, R. J., (1999). Postural stabilization of looking, Journal of Experimental Psychology, 25, 1641-1658.
- Suzuki, J., Matsunaga, T., Tokumatsu, K., Taguchi, K., Watanabe, Y., (1996). Q&A and a manual in Stabilometry, Equilibrium Res., 55(1), 64-77.
- Takada, H., Kitaoka, Y., Shimizu, Y., (2001). Mathematical index and model in stabilometry, Forma, 16(1), 17-46.
- Takada, H., Kitaoka, Y., Ichikawa, S., Miyao, M., (2003). Physical Meaning of Geometrical Index for Stabilometry, Equilibrium Res, 62(3), 168-180.
- Takada, H., Morimoto, T., Tsunashima, H., Yamazaki, T., Hoshina, H., Miyao, M., (2006). Applications of Double-Wayland algorithm to detect anomalous signals, Forma, 21(2), 159-167.
- Takada, H., Fujikake, K., Miyao, M., Matsuura, Y., (2007). Indices to detect visually induced motion sickness using stabilometry, Proc. VIMS2007, 178-183.
- Takeda, T., Izumi, S., Sagawa, K., (1995). On the correlation between head movement and movement of the center of gravity using HMD, Proc. 1995 IEICE General Conference, 203.
- Wayland, R., Bromley, D., Pickett, D., Passamante, A., (1993). Recognizing determinism in a time series, Phys. Rev. Lett., 70, 530-582.
Paper Citation
in Harvard Style
Hiroki T., Yasuyuki M., Kazuhiro F. and Masaru M. (2011). BIORESPONSE TO STEREOSCOPIC MOVIES PRESENTED VIA A HEAD-MOUNTED DISPLAY . In Proceedings of the International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2011) ISBN 978-989-8425-35-5, pages 433-437. DOI: 10.5220/0003155104330437
in Bibtex Style
@conference{biosignals11,
author={Takada Hiroki and Matsuura Yasuyuki and Fujikake Kazuhiro and Miyao Masaru},
title={BIORESPONSE TO STEREOSCOPIC MOVIES PRESENTED VIA A HEAD-MOUNTED DISPLAY
},
booktitle={Proceedings of the International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2011)},
year={2011},
pages={433-437},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003155104330437},
isbn={978-989-8425-35-5},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2011)
TI - BIORESPONSE TO STEREOSCOPIC MOVIES PRESENTED VIA A HEAD-MOUNTED DISPLAY
SN - 978-989-8425-35-5
AU - Hiroki T.
AU - Yasuyuki M.
AU - Kazuhiro F.
AU - Masaru M.
PY - 2011
SP - 433
EP - 437
DO - 10.5220/0003155104330437