INCREASING RELIABILITY AND INFORMATION CONTENT OF PULSE OXIMETRIC SAHS SCREENING ALGORITHMS
Nicole Gross, Jennifer Friedmann, Christophe Kunze, Wilhelm Stork, Daniel Sánchez Morillo, Antonio Leon Jimenez, Luis Felipe Crespo Foix
2011
Abstract
About 3% of people suffer from sleep apnea-hypopnea syndrome SAHS. SAHS is a sleep associated respiratory disorder that negatively affects life quality and life expectancy. It is assumed that more than 80% of SAHS concerned are neither diagnosed nor therapied. Reliable and easy-handling SAHS screening systems are needed. Within this study, the reliability of pulse oximeter as a well-established, non-invasive medical device is examined for SAHS screening. Reliability of existing SAHS screening algorithms will be assessed. Hereby, the focus is on the influence of different desaturation detection strategies and the dependence on thresholds. Critiques on pulse oximetry as SAHS screening device will be responded. In this regard, guideline conform grey area integration in SAHS screening (concerning apnea-hypopnea index AHI between 5 and 15) is recommended. In particular, as by grey area integration an improvement of convenient SAHS screening algorithm reliabilities of about 7.3% in sensitivity and 8.7 % in specificity was achieved even in the most reliable tested algorithm. In a final step, room for improvement of screening results interpretation even without sleep medicine expert skills is indicated. In connection to this, possibilities of short-term frequency analysis of SpO2 data are demonstrated in its prospects for individualized SAHS screening quality.
References
- Downey, R., Gold, P. M., Wickramasinghe H., Medscape 2010, Obstructive Sleep Apnea
- Esteller, E., Huerta, P., Segarra, F., Matiñó, E., Enrique, A., Ademà, J. M., Acta Otorrinolaringol Esp. 2008, Undiagnosed (corrected) cases of obstructive sleepapnoea syndrome: a new reason for involvement of otorhinolaryngologists, 59(2):62-9.
- Finkel, K. J., Searleman, A. C., Tymkew, H., Tanaka, C. Y., Saager, L., Safer-Zadeh, E., Bottros, M., Selvidge, J. A., Jocobsohn, E., Pulley, D., Duntley, S., Becker, C., Avidan, M. S., Sleep Med 2009, Prevalence of undiagnosed obstructive sleep apnea among adult surgical patients in an academic medical center, 10(7):753-8.
- Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., McDowell Anderson, W., Hudgel, D. W., McEvoy, R. D., Loube, I. L., Chest 2003, Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature: An Evidence Review Cosponsored by the American Academy of Sleep Medicine, the American College of Chest Physicians, and the American Thoracis Society, 124:1543-1579.
- Gross, N., Kunze, C., Stork, W., Müller-Glaser, K., Rojas Ojeda, J. L., Crespo Foix, L. F., Sánchez Morillo, D., León, A., BMT 2007, Schlafapnoeprädiagnose und - klassifikation basierend auf nicht-linearer Analyse pulsoximetrischer Daten.
- Grupo español de sueño GES, Sociedad Española de Neumología y Cirurgía Torácico SEPAR 2005, Documento de consenso nacional sobre el síndrome de apneas-hipopneas del sueño (SAHS)
- Kapur, V., Blough, D. K., Sandblom, R. E., Hert, R., de Maine, J. B., Sullivan, S. D., Psaty, B. M., SLEEP 1999, The Medical Cost of Undiagnosed Sleep Apnea, 22(6):749-755.
- Konietzko, N., Teschler, H., Freitag, L., 1998, Schlafapnoe, Pathopysionlogie der obstruktiven Schlafapnoe, 13.
- Mayer, G., Fietze, I., Fischer, J., Penzel, T., Riemann, D., Rodenbeck, A., Sitter, H. Teschler, H., Somnologie 2009, S3-Leitlinie: Nicht erholsamer Schlaf / Schlafstörungen.
- Netzer, N., Eliasson, A. H., Netzer, C., Kristo, D. A., Chest 2001; Overnight Pulse Oximetry for SleepDisordered Breathing in Adults: A Review. 120:625- 633.
- Oczenski, W., Georg Thieme Verlag 2008, Atmen - Atemhilfen - Atmphysiologie und Beatmungstechnik, 8.Auflage, p.370-371.
- Rechtschaffen, A., Kales, A., 1968, Manual of Standardized Technology, Techniques and Scoring System for Sleep Association for the Psychophysiological Study of Sleep
- Rauscher, H., Popp, W., Zwick, H., Lung 1991, Computerized Detection of Respiratory Events during Sleep from Rapid Increase in Oxyhemoglobin Saturation, 169:335-342.
- Torre-Bouscoulet, L., Castorena-Maldonado, A., BañosFlores, R., Vázquez-García, J. C., Meza-Vargas, M. S., Pérez-Padilla, R., Arch Bronconeumol 2007, Agreement between oxygen desaturation index and apnea-hypopnea index in adults with suspected obstructed sleep apnea at an altitude of 2240m, 43(12):640-54.
- Wantke, F., J Kardiol 2008, Beatmungstherapie bei Schlafapnoe - Indikation und Auswirkungen auf internistische Erkrankungen - ein Minireview, 15:364-8.
- Wessendorf, T. E., Alymov, G., Wang, Y.-M., Stampa, J. Thilmann, A. F., Teschler, H., Pneumologie 2002, Pulsoximetrie als Schlafapnoescreening bei Schlaganfallpatienten, 56:357-362.
- Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., Badr, S., N Engl J Med 1993, The occurrence of sleepdisordered breathing among middle-aged adults. 328(17):1230-5.
- Young, T., Evans, L., Finn, L., Palte, M., Sleep 1997, Estimation of the clinically diagnosed proportion of sleep apnea syndrome in middle-aged men and women, 20:705-706.
- Zafar, S., Ayappa, I., Norman, R. G., Krieger, A. C., Wals-leben, J. A., Rapoport, D. M., Chest 2005, Choice of Oximeter Affects Apnea-Hypopnea Index, 127:80-88.
- Zamarrón, C., Romero, P. V., Rodriguez, J. R., Gude, F., Clinical Science 1999, Oximetry spectral analysis in the diagnosis of obstructive sleep apnoea, 97:467-473.
Paper Citation
in Harvard Style
Gross N., Friedmann J., Kunze C., Stork W., Sánchez Morillo D., Leon Jimenez A. and Crespo Foix L. (2011). INCREASING RELIABILITY AND INFORMATION CONTENT OF PULSE OXIMETRIC SAHS SCREENING ALGORITHMS . In Proceedings of the International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2011) ISBN 978-989-8425-35-5, pages 438-445. DOI: 10.5220/0003156104380445
in Bibtex Style
@conference{biosignals11,
author={Nicole Gross and Jennifer Friedmann and Christophe Kunze and Wilhelm Stork and Daniel Sánchez Morillo and Antonio Leon Jimenez and Luis Felipe Crespo Foix},
title={INCREASING RELIABILITY AND INFORMATION CONTENT OF PULSE OXIMETRIC SAHS SCREENING ALGORITHMS},
booktitle={Proceedings of the International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2011)},
year={2011},
pages={438-445},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003156104380445},
isbn={978-989-8425-35-5},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Bio-inspired Systems and Signal Processing - Volume 1: BIOSIGNALS, (BIOSTEC 2011)
TI - INCREASING RELIABILITY AND INFORMATION CONTENT OF PULSE OXIMETRIC SAHS SCREENING ALGORITHMS
SN - 978-989-8425-35-5
AU - Gross N.
AU - Friedmann J.
AU - Kunze C.
AU - Stork W.
AU - Sánchez Morillo D.
AU - Leon Jimenez A.
AU - Crespo Foix L.
PY - 2011
SP - 438
EP - 445
DO - 10.5220/0003156104380445