A NEW METHOD FOR DETECTION OF TOTAL HIP REPLACEMENT LOOSENING - Development and First Results of a Novel Mechano-acoustical Sensor
Cathérine Ruther, Hartmut Ewald, Wolfram Mittelmeier, Daniel Kluess, Andreas Fritsche, Rainer Bader
2011
Abstract
Currently applied diagnostic methods for loosening of total hip replacements often result in imprecise identification of implant fixation and in the worst case unnecessary revision surgery. Developed sensors integrated in implants require adequate energy supply, which in most cases is achieved by inductive coupling and complex data telemetry. In order to avoid a telemetric apparatus, we developed a passive concept of a novel in vivo method to improve diagnostic investigations of total hip replacement loosening. A mechano-acoustical sensor, attached on small membranes inside the femoral hip stem, is proposed and enables osseous anchorage detection. The sensor is excited and detected by extracorporeal coils. First functional models show significant differences between different material layers located at the membrane. The novel in vivo sensor system has a promising potential to detect implant loosening.
References
- Temmerman, O. P., Raijmakers, P. G., Berkhof, J., Hoekstra, O. S., Teule, G. J., Heyligers, I. C., 2005. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis. In: Journal of Bone and Joint Surgery, 87, pp. 781-785.
- Pastrav, L. C., Jaeques, S. V. N., Jonkers, I., Van der Perre, G., Mulier, M., 2009. In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses. In: Journal of Orthopaedic Seurgery and Research. 4, pp. 1-10.
- Marschner, U., Jettkant, B., Ruwisch, D., Zhu, Y., Grätz, H., Fischer W. J., Clasbrummel, B., 2007. FEM simulation and wireless measurement of hip prosthesis vibrations for loosening detection. European Symposium , Technical Aids for Rehabilitation, 25-26 January 2007, Berlin, pp. 87-88.
- Puers, R., Catrysse, M., Vandevoorde, G., Collier, R. J., Louridas, E., Burny, F., Donkerwolcke, M., Moulart, F.,1999. A telemetry system for the detection of hip prosthesis loosening by vibration analysis. In: Sensors and Actuators, 85, pp. 42-47.
- Ruther, C., Ewald, H., Biemann, A., Nierath, H., Bader, R., Kluess, D., 2010. A New Concept for NonInvasive Radiation-Free Detection of Implant Loosening. 56th Annual Meeting of the Orthopaedic Research Society, New Orleans, USA, 6-9 March 2010, #2413.
Paper Citation
in Harvard Style
Ruther C., Ewald H., Mittelmeier W., Kluess D., Fritsche A. and Bader R. (2011). A NEW METHOD FOR DETECTION OF TOTAL HIP REPLACEMENT LOOSENING - Development and First Results of a Novel Mechano-acoustical Sensor . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 70-73. DOI: 10.5220/0003165900700073
in Bibtex Style
@conference{biodevices11,
author={Cathérine Ruther and Hartmut Ewald and Wolfram Mittelmeier and Daniel Kluess and Andreas Fritsche and Rainer Bader},
title={A NEW METHOD FOR DETECTION OF TOTAL HIP REPLACEMENT LOOSENING - Development and First Results of a Novel Mechano-acoustical Sensor},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={70-73},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003165900700073},
isbn={978-989-8425-37-9},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - A NEW METHOD FOR DETECTION OF TOTAL HIP REPLACEMENT LOOSENING - Development and First Results of a Novel Mechano-acoustical Sensor
SN - 978-989-8425-37-9
AU - Ruther C.
AU - Ewald H.
AU - Mittelmeier W.
AU - Kluess D.
AU - Fritsche A.
AU - Bader R.
PY - 2011
SP - 70
EP - 73
DO - 10.5220/0003165900700073