PORTABLE DEVICE TO MONITOR AUTONOMIC NERVOUS SYSTEM ACTIVITY THROUGH CLOTHES
Kang Moo Lee, Seung Min Lee, Gih Sung Chung, Hong Ji Lee, Yong Gyu Lim, Kwang Suk Park
2011
Abstract
Heart rate variability (HRV) reflects the autonomic nervous system (ANS) activity and HRV parameters are extracted from electrocardiogram (ECG) signal. However, the conventional ECG electrodes such as Ag/AgCl electrode make a person uncomfortable due to electrolytic paste or conductive adhesive used for ensuring good contact between electrode and skin. In this study, the portable device with capacitive electrodes was designed to monitor ANS activity through clothes. By using capacitive electrodes, ECG can be measured without direct skin-contact through capacitive coupling between the body and the electrodes. To evaluate the possibility that the ANS activity can be monitored using the capacitive electrode system, HRV parameters extracted from the capacitive electrodes were compared with HRV parameters extracted from Ag/AgCl electrodes. Results showed that there was no significant difference between the HRV parameters of two different electrodes.
References
- Conny M. A. van Ravenswaaij-Arts, Louis A. A. Kollee, Jeroen C. W. Hopman, Gerard B. A. Stoelinga, Herman P. van Geijn, 1993. Heart Rate Variability. Annals of Internal Medicine, vol.118, pp. 436-447.
- HV Barron, M. D Lesh, 1996. Autonomic nervous system and sudden cardiac death. J Am Coll Cardiol, vol. 27, pp. 1053-1560.
- Lim YG, Kim KK, Park KS, 2006. ECG measurement on a chair without conductive contact. IEEE Trans. Biomedical Engineering, vol. 53, pp. 956-959.
- Lee S. M, Sim K. S, Kim K. K, Lim Y. G, Park K. S, 2010. Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement. Medical and Biological engineering and Computing, vol. 48, no. 5, pp. 447-457.
- Packer M, Bristow M. R, Cohn JN, et al., 1996. The effect of carvedilol on morbidity and mortality in patients with chronic heart failure. N Engl J Med, vol. 334, pp 1349-1355.
- Pan J, Tompkins W. J, 1985. A real-time QRS detection algorithm. IEEE Trans. Biomedical Engineering, vol. 32, pp. 230-236.
- P. J Podrid, T Fuchs, R Candinas, 1990. Role of the sympathetic nervous system in the genesis of ventricular arrhythmia. Circulation, Aug;82(2 Suppl):I103-113.
- U. Rajendra Acharya, K. Paul Joseph, N. Kannathal, C. M. Lim, J. S. Suri, 2006. Heart rate variability: a review. Medical and Biological Engineering and Computing, vol. 44, pp. 1031-1051.
Paper Citation
in Harvard Style
Lee K., Lee S., Chung G., Lee H., Lim Y. and Park K. (2011). PORTABLE DEVICE TO MONITOR AUTONOMIC NERVOUS SYSTEM ACTIVITY THROUGH CLOTHES . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 276-279. DOI: 10.5220/0003288502760279
in Bibtex Style
@conference{biodevices11,
author={Kang Moo Lee and Seung Min Lee and Gih Sung Chung and Hong Ji Lee and Yong Gyu Lim and Kwang Suk Park},
title={PORTABLE DEVICE TO MONITOR AUTONOMIC NERVOUS SYSTEM ACTIVITY THROUGH CLOTHES},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={276-279},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003288502760279},
isbn={978-989-8425-37-9},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - PORTABLE DEVICE TO MONITOR AUTONOMIC NERVOUS SYSTEM ACTIVITY THROUGH CLOTHES
SN - 978-989-8425-37-9
AU - Lee K.
AU - Lee S.
AU - Chung G.
AU - Lee H.
AU - Lim Y.
AU - Park K.
PY - 2011
SP - 276
EP - 279
DO - 10.5220/0003288502760279