A COMPUTERIZED SELF VISUAL ACUITY TESTING SYSTEM - Method of the Optotype Presentation and Adjustment

WooBeom Lee, ChangYur Choi

2011

Abstract

This paper suggests the method of the optotype presentation and adjustment for a computerized self visual acuity test. The proposed method is guaranteed credibility by ‘KS P ISO 8596’ in 2006. Also this system provides convenience to people who take an eyesight test based on gesture recognition of them. And the method of the optotype adjustment for a computerized self visual acuity test is able to measure objective eyesight that excluded subjective judgment of inspector and conjecture of subject’s memorization. According to result of experimental comparison between method of using real visual-acuity chart and the system of a computerized self visual acuity test, Our system showed the 98% consistency in the limit of the ±1 visual-acuity level error.

References

  1. Bach, M. et al. (2009). Resolving the clinical acuity categories "hand motion" and "counting finger" using the Freiburg Visual Acuity Test(FrACT). Graefes Arch Clin Exp Ophthalmol 247, 137-142.
  2. Harrison, E. R. (1953). Visual Acuity and the Cone Cell Distribution of the Retina. Brit. J. Ophthal. 37, 38-542.
  3. Kniestedt, C. and Stamper, R. L. (2003). Visual acuity and its measurement. Ophthalmol. Clin. N. Am (16), 155-177.
  4. KOREA INDUSTRIAL STANDARD. (2006). P ISO 8596:2006, Ophthalmic Optic - Visual Acuity Testing - Standard Optotype and its Presentation.
  5. KOREA INDUSTRIAL STANDARD. (2002). Q ISO 3: 2002, Preferred Number.
  6. Lee, W. B. and Choi, C. Y. (2009). A Self-Visual Acuity Testing System by the KS Standard Optotype. Proceedings of the Korean Information Processing Society Fall Conference, 16(2), 893-894.
Download


Paper Citation


in Harvard Style

Lee W. and Choi C. (2011). A COMPUTERIZED SELF VISUAL ACUITY TESTING SYSTEM - Method of the Optotype Presentation and Adjustment . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011) ISBN 978-989-8425-37-9, pages 432-435. DOI: 10.5220/0003289004320435


in Bibtex Style

@conference{biodevices11,
author={WooBeom Lee and ChangYur Choi},
title={A COMPUTERIZED SELF VISUAL ACUITY TESTING SYSTEM - Method of the Optotype Presentation and Adjustment},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)},
year={2011},
pages={432-435},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0003289004320435},
isbn={978-989-8425-37-9},
}


in EndNote Style

TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2011)
TI - A COMPUTERIZED SELF VISUAL ACUITY TESTING SYSTEM - Method of the Optotype Presentation and Adjustment
SN - 978-989-8425-37-9
AU - Lee W.
AU - Choi C.
PY - 2011
SP - 432
EP - 435