REFERENCES
Allen, P., Josephs, O., Turner, R., 2000. A method for
removing imaging artifact from continuous EEG
recorded during functional MRI. NeuroImage 12, 230-
239.
Anami, K., Mori, T., Tanaka, F., Kawagoe, Y., Okamoto,
J., Yarita, M., Ohnishi, T., Yumoto, M., Matsuda, H.,
Saitoh, O., 2003. Stepping stone sampling for
retrieving artifact-free electroencephalogram during
functional magnetic resonance imaging. NeuroImage
19, 281–295.
De Munck, J., Van Houdt, P., Gonçalves, S., Van Wegen,
E., Ossenblok, P., 2013. Novel artefact removal
algorithms for co-registered EEG/fMRI based on
selective averaging and subtraction. NeuroImage 64,
407-415.
El-Tatar, A., Fokapu, O., 2011. Modeling MR induced
artifacts contaminating electrophysiological signals
recorded during MRI. Proceedings of the 33
rd
Annual
International Conference of the IEEE EMBS 2011,
Boston, Massachusetts, August 30 – September 3,
2011. 7135-7138.
Ferreira, J., Cluitmans, P., Aarts, R.M., 2012. Gradient
artefact correction in the EEG signal recorded within
the fMRI scanner. Proceedings of the 5
th
International
Conference on Bio-inspired Systems and Signal
Processing, BIOSIGNALS 2012, Vilamoura, Portugal,
February 1 – 4, 2012. 110-117.
Ferreira, J., Cluitmans, P., Aarts, R.M., 2013a. Gradient
artefact modelling using a set of sinusoidal waveforms
for EEG correction during continuous fMRI. Signal
Processing Research 2, 39-48.
Ferreira, J., Cluitmans, P., Aarts, R.M., 2013b. Non-linear
filter for gradient artefact correction during
simultaneous EEG-fMRI. Signal Processing Research
2, 55-63.
Ferreira, J., Cluitmans, P., Aarts, R.M., 2013c. Detection
of sharp wave activity in biological signals using
differentiation between consecutive samples.
Proceedings of the 6
th
International Conference on
Bio-inspired Systems and Signal Processing,
BIOSIGNALS 2013, Barcelona, Spain, February 11 –
14, 2013. 327-332.
Fritsch, F., Carlson, R., 1980. Monotone piecewise cubic
interpolation. SIAM. J. Numer. Anal. 17, 238-246.
Garreffa, G., Carnì, M., Gualniera, G., Ricci, G.B.,
Bozzao, L., De Carli, D., Morasso, P., Pantano, P.,
Colonnese, C., Roma, V., Maraviglia, B., 2003. Real-
time MR artifacts filtering during continuous
EEG/fMRI acquisition. Magn. Res. Imaging. 21, 1175-
1189.
Gonçalves, S., Pouwels, P., Kuijer, J., Heethaar, R., De
Munck, J., 2007. Artifact removal in co-registered
EEG/fMRI by selective average subtraction. Clin.
Neurophysiol. 118, 823-838.
Koskinen, M., Vartiainen, N., 2009. Removal of imaging
artifacts in EEG during simultaneous EEG/fMRI
recording: reconstruction of a high-precision artifact
template. NeuroImage 46, 160-167.
Kreyszig, E., 2011. Advanced engineering mathematics.
10
th
e. Wiley: New York.
Moosmann, M., Schönfelder, V., Specht, K., Scheeringa,
R., Nordby, H., Hugdahl, K., 2009. Realignment
parameter-informed artefact correction for
simultaneous EEG-fMRI recordings. NeuroImage 45,
1144-1150.
Niazy, R., Beckmann, C., Iannetti, G., Brady, J., Smith, S.,
2005. Removal of FMRI environment artifacts from
EEG data using optimal basis sets. NeuroImage 28,
720-737.
Olson, W., 2010. Basic concepts of medical
instrumentation. In J. Webster (ed.), Medical
instrumentation: application and design. 4
th
ed. Wiley:
New York.
Ritter, P., Becker, R., Freyer, F., Villringer, A., 2010. EEG
quality: the image acquisition artifact. In C. Mulert, L.
Limieux (eds.), EEG-fMRI: Physiological basis,
technique and applications. Springer: Verlag, Berlin,
Heidelberg.
Sun, L., Hinrichs, H., 2009. Simultaneously recorded
EEG-fMRI: removal of gradient artifacts by
subtraction of head movement related average artifact
waveforms. Hum. Brain Mapp. 30, 3361–3377.
Van Liempt, S., Vermetten, E., Lentjes, E., Arends, J.,
Westenberg, H., 2011. Decreased nocturnal growth
hormone secretion and sleep fragmentation in combat-
related posttraumatic stress disorder; potential
predictors of impaired memory consolidation.
Psychoneuroendocrino. 36, 1361-1369.
Wolberg, G., Alfy, I., 1999. Monotonic cubic spline
interpolation. Proceedings of the Computer Graphics
International Conference, CGI 1999, Canmore,
Canada, June 7 – 11, 1999. 188-195.
Yan, W., Mullinger, K., Brookes, M., Bowtell, R., 2009.
Understanding gradient artefacts in simultaneous
EEG/fMRI. NeuroImage 46, 459-471.
BIOSIGNALS2014-InternationalConferenceonBio-inspiredSystemsandSignalProcessing
220