Design, Development and Implementation of µSPC Phantom for Quality Control in Micro-SPECT / CT and Micro-PET / CT Systems - Qualitative Study
Hatem Besbes, Nejla Majoul, Fatma Ben Hamida, Philippe Choquet
2014
Abstract
The μSPC phantom is designed for the quality control of micro-SPECT/CT and micro-PET/CT systems. However, it is an assembly of six patterns stored in a cylindrical box and enabling to control both micro-SPECT unit in terms of uniformity, linearity and spatial resolution than micro-CT unit in terms of uniformity , linearity, spatial resolution, diffusion rate, low contrast detectability, linearity of Hounsfield coefficients and slice thickness. The construction material is plexiglass. As for the implementation, it was made on a micro-SPECT/CT machine of the type "speCZT eXplore CT 120".
References
- Dillenseger, J. P., Guillaud, B., Goetz, C., Sayeh, A., Schimpf, R., Constantinesco, A., Choquet, P., 2013. Coregistration of data sets from a micro-SPECT/CT and a preclinical 1.5T MRI, Nuclear Instruments and Methods in Physics Research A 702(2013)144-147.
- Glover, D. K., Kundu, B., Schelbert, H. R., 2010. Chapter11: State-of-the-Art Instrumentation for PET and SPECT Imaging in Small Animals; Clinical nuclear cardiology, state of the art and future directions, MOSBY, ELSEVIER.
- Hohui, H., Ingtsung, H., 2010. Image Reconstructions from Limit Views and Angle Coverage Data for a Stationary Multi-Pinhole SPECT System, TSINGHUA SCIENCE AND TECHNOLOGY ISSNl l1007-0214l l07/20l lpp44-49 Volume 15, Number 1.
- Jan, M., Ni, Y., Chen, K., Liang, H. Chuang, K., Fu, Y., 2006. A combined micro-PET/CT scanner for small animal imaging, Nuclear Instruments and Methods in Physics Research A 569, 314-318.
- Lina, K., Liu, H., Hsu, P., Chung, Y., Huang, W., Chen, J., Wey, S., Yen, T., Hsiao, I., 2009. Quantitative micro-SPECT/CT for detecting focused ultrasoundinduced blood-brain barrier opening in the rat, Nuclear Medicine and Biology 36, 853-861.
- Matthews, P. M., Coatney, R., Alsaid, H., Jucker, B., Ashworth, S., Parker, C., Changani, K., 2013. Technologies: preclinical imaging for drug development, Drug Discovery Today: Technologies | Translational Pharmacology: From Animal to Man and Back Vol. 10, No. 3, 343-350.
- Moran, C. M., Pye, S. D., Ellis, W., Janeczko, A., Morris, K. D., Mcneilly, A. S., Fraser, H. M., 2011. A comparison of the imaging performance of high resolution ultrasound scanners for preclinical imaging, Ultrasound in Med. & Biol., Vol. 37, No. 3, pp. 493-501.
- Panetta, D., Belcari, N., Del Guerra, A., Bartolomei, A., Salvadori, P. A., 2012. Analysis of image sharpness reproducibility on a novel engineered micro-CT scanner with variable geometry and embedded recalibration software, Physica Medica 28, 166-173.
- Peremans, K., Vermeire, S., Dobbeleir, A., Gielen, I., Samoy, Y., Piron, K., Vandermeulen, E., Slegers, G., van Bree, H., De Spiegeleer , B., Dik, K., 2011. Recognition of anatomical predilection sites in canine elbow pathology on bone scans using micro-single photon emission tomography, The Veterinary Journal 188 64-72.
- Seret, A., 2011. NEMA NU1-2001 performance tests of four Philips Brightview cameras, Nuclear Instruments and Methods in Physics Research A 648, 589-592.
- Slavine, N. V., Antich, P. P., 2008. Practical method for radioactivity distribution analysis in small-animal PET cancer studies, Applied Radiation and Isotopes 66, 1861- 1869.
Paper Citation
in Harvard Style
Besbes H., Majoul N., Ben Hamida F. and Choquet P. (2014). Design, Development and Implementation of µSPC Phantom for Quality Control in Micro-SPECT / CT and Micro-PET / CT Systems - Qualitative Study . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2014) ISBN 978-989-758-013-0, pages 283-288. DOI: 10.5220/0004915702830288
in Bibtex Style
@conference{biodevices14,
author={Hatem Besbes and Nejla Majoul and Fatma Ben Hamida and Philippe Choquet},
title={Design, Development and Implementation of µSPC Phantom for Quality Control in Micro-SPECT / CT and Micro-PET / CT Systems - Qualitative Study},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2014)},
year={2014},
pages={283-288},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0004915702830288},
isbn={978-989-758-013-0},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2014)
TI - Design, Development and Implementation of µSPC Phantom for Quality Control in Micro-SPECT / CT and Micro-PET / CT Systems - Qualitative Study
SN - 978-989-758-013-0
AU - Besbes H.
AU - Majoul N.
AU - Ben Hamida F.
AU - Choquet P.
PY - 2014
SP - 283
EP - 288
DO - 10.5220/0004915702830288