Acoustic noise is a major source of discomfort for patients undergoing magnetic resonance imaging (MRI) examination. Loud noise is generated from fast gradient switching during MRI scanning. The noise level is reduced by wearing hearing protection devices, but the noise cannot be entirely avoided. Patient distraction techniques can shift the attention away from the annoying noise. We implemented a simple and low-cost system for patient distraction using visual effects that are synchronized to the gradient acoustic noise. This multisensory approach for patient distraction is implemented on a 3.0T scanner and tested in six healthy adult volunteers. After the scan was completed, the volunteers were asked about their scan experience with visualization, rating their preference on a 0-10 scale. The images were visual inspected for any artifacts. All volunteers indicated improved experience with the proposed visualization system with an average score of 6.3. The image quality was not affected by visualization.

Download


Paper Citation


in Harvard Style

Gabr R. and Narayana P. (2016). Patient Distraction and Entertainment System for Magnetic Resonance Imaging using Visual Effects Synchronized to the Scanner Acoustic Noise.In Proceedings of the 11th Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications - Volume 3: VISAPP, (VISIGRAPP 2016) ISBN 978-989-758-175-5, pages 319-323. DOI: 10.5220/0005680503190323


in Bibtex Style

@conference{visapp16,
author={Refaat E. Gabr and Ponnada A. Narayana},
title={Patient Distraction and Entertainment System for Magnetic Resonance Imaging using Visual Effects Synchronized to the Scanner Acoustic Noise},
booktitle={Proceedings of the 11th Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications - Volume 3: VISAPP, (VISIGRAPP 2016)},
year={2016},
pages={319-323},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005680503190323},
isbn={978-989-758-175-5},
}


in EndNote Style

TY - CONF

JO - Proceedings of the 11th Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications - Volume 3: VISAPP, (VISIGRAPP 2016)
TI - Patient Distraction and Entertainment System for Magnetic Resonance Imaging using Visual Effects Synchronized to the Scanner Acoustic Noise
SN - 978-989-758-175-5
AU - Gabr R.
AU - Narayana P.
PY - 2016
SP - 319
EP - 323
DO - 10.5220/0005680503190323