mNetra: A Fundoscopy based Optometer
Vijay Kumar, Kolin Paul
2016
Abstract
Untreated refractive error in the eye is one of the leading causes of preventable blindness. The devices necessary for this is expensive and often requires skilled technicians to operate. In this paper, a common off the shelf ophthalmoscope has been modified and integrated with a smart phone to build an affordable optometer. The device has been tested on a statistically significant population with refractive error range from −8.00D to +3.50D. We found a reasonably good correlation with other prevalent methods of measuring refractive error in the eye.
References
- Berger, I. B., Spitzberg, L. A., Nnadozie, J., Bailey, N., Feaster, J., Kuether, C., Tran, M., and Swann, S. (1993). Testing the focometer-a new refractometer. Optometry & Vision Science, 70(4):332-338.
- Cameraculture.media.mit.edu (2015). Netra/catra, camera culture; http: //cameraculture.media.mit. edu/cubeportfolio/netracatra/.
- Dave, T. (2004). Automated refraction: design and applications. Optom Today, 48:28-32.
- Ko, D.-S. and Lee, B.-H. (2006). Optics of refractometers for refractive power measurement of the human eye. Journal of the Optical Society of Korea, 10(4):145- 156.
- Pamplona, V. F., Mohan, A., Oliveira, M. M., and Raskar, R. (2010). Netra: interactive display for estimating refractive errors and focal range. In ACM Transactions on Graphics (TOG), volume 29, page 77. ACM.
- Pascolini, D. and Mariotti, S. P. (2011). Global estimates of visual impairment: 2010. British Journal of Ophthalmology, pages bjophthalmol-2011.
- Paul, K. and Kumar, V. (2015). Fundus imaging based affordable eye care. In Proceedings of the International Conference on Health Informatics, pages 634-641.
- PeekVision (2015). Professional eye exams from a phone.http://www.peekvision.org/.
- Resnikoff, S., Pascolini, D., Mariotti, S. P., and Pokharel, G. P. (2008). Global magnitude of visual impairment caused by uncorrected refractive errors in 2004. Bulletin of the World Health Organization, 86(1):63-70.
- Saxena, R., Vashist, P., Tandon, R., Pandey, R., Bhardawaj, A., Menon, V., and Mani, K. (2015). Prevalence of myopia and its risk factors in urban school children in delhi: The north india myopia study (nim study). PloS one, 10(2).
- Welchallyn.com (2015). Welch allyn panoptic ophthalmoscope: A difference you can see. http:// www.welchallyn.com/promotions/panoptic/def ault.htm.
- WHO.int (2014). Who-visual impairment and blindness, fact sheet no 282; http://www.who.int/mediacentre/ factsheets/fs282/en/.
- Zhou, Y. and Kassalow, J. (2010). Preliminary evaluation of svone autorefractor for low order refractive errors.
Paper Citation
in Harvard Style
Kumar V. and Paul K. (2016). mNetra: A Fundoscopy based Optometer . In Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 5: HEALTHINF, (BIOSTEC 2016) ISBN 978-989-758-170-0, pages 83-92. DOI: 10.5220/0005698500830092
in Bibtex Style
@conference{healthinf16,
author={Vijay Kumar and Kolin Paul},
title={mNetra: A Fundoscopy based Optometer},
booktitle={Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 5: HEALTHINF, (BIOSTEC 2016)},
year={2016},
pages={83-92},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005698500830092},
isbn={978-989-758-170-0},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 9th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 5: HEALTHINF, (BIOSTEC 2016)
TI - mNetra: A Fundoscopy based Optometer
SN - 978-989-758-170-0
AU - Kumar V.
AU - Paul K.
PY - 2016
SP - 83
EP - 92
DO - 10.5220/0005698500830092