Preliminary Findings of Feasibility of a Wearable Soft-robotic Glove Supporting Impaired Hand Function in Daily Life - A Soft-robotic Glove Supporting ADL of Elderly People
B. Radder, G. B. Prange-Lasonder, A. I. R. Kottink, L. Gaasbeek, J. Holmberg, T. Meyer, J. H. Buurke, J. S. Rietman
2016
Abstract
Elderly people frequently encounter difficulties in independently performing activities of daily living (ADL) due to a reduced hand function. Robotic assistive devices have the potential to provide the assistance that is necessary to perform ADL independently without the need of personal assistance. Therefore, the objective of the present study was to explore feasibility of a wearable soft-robotic glove (ironHand (iH) system) that can support hand function of elderly people in daily life. Thirty elderly people (>56 years) with a reduced hand function resulting in difficulties in performing ADL were recruited to perform six functional tasks three times with and without the iH system. Evaluation measurements consisted of functional tasks performance times and user-acceptance of the iH system, measured by the System Usability Scale (SUS). Participants improved their functional task performance after multiple attempts either with and without the glove, but performed significantly faster without the glove (p≤0.032). Besides, the mean of the SUS score for the iH system was 70.1%. Although this indicates a good probability for acceptance in the field, several design adaptations are necessary to have a user-friendly and accepted assistive device.
References
- Ambrosini, E., Ferrante, S., Rossini, M., Molteni, F., Gföhler, M., Reichenfelser, W., Duschau-Wicke, A., Ferrigno, G. & Pedrocchi, A. 2014. Functional and usability assessment of a robotic exoskeleton arm to support activities of daily life. Robotica, 32, 1213-1224.
- Balasubramanian, S., Klein, J. & Burdet, E. 2010. Robotassisted rehabilitation of hand function. Current Opinion in Neurology, 23, 661-670.
- Bangor, A., Kortum, P.T. & Miller, J.T. 2008. An empirical evaluation of the system usability scale. Intl. Journal of Human-Computer Interaction, 24, 574-594.
- Brooke, J. 1996. SUS-A quick and dirty usability scale. Usability evaluation in industry, 189.
- Carmeli, E., Patish, H., & Coleman, R. 2003. The aging hand. The Journals of Gerontology Series A: Biological Sciences and Medical Sciences, 58, M146-M152.
- Demain, S., Burridge, J., Ellis-Hill, C., Hughes, A.M., Yardley, L., Tedesco-Triccas, L., & Swain, I. 2013. Assistive technologies after stroke: self-management or fending for yourself? A focus group study. BMC Health Services Research, 13, 334.
- Frappier, J. 2011. Clinico-economic study of the JACO robotic arm for powered wheelchair users with upperextremity disabilities. by Data4Actions Inc. for Kinova, Canada.
- Hackel, M. E., Wolfe, G.A., Bang, S.M., & Canfield, J.S. 1992. Changes in hand function in the aging adult as determined by the Jebsen Test of Hand Function. Physical Therapy, 72, 373-377.
- Hoenig, H., Taylor, J.D.H. & Sloan, F.A. 2003. Does assistive technology substitute for personal assistance among the disabled elderly? American Journal of Public Health, 93, 330-337.
- Kinoshita, H. & Francis, P.R. 1996. A comparison of prehension force control in young and elderly individuals. European journal of applied physiology and occupational physiology, 74, 450-460.
- Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., JansenTroy, A. & Leonhardt, S. 2014. A survey on robotic devices for upper limb rehabilitation. Journal of NeuroEngineering and Rehabilitation, 11.
- Ni, L. 2013. Development and Testing of Sample Therapeutic Programs on the Microsoft Kinect for Children with Cerebral Palsy.
- Nijenhuis, S.M., Prange, G.B., Amirabdollahian, F., Sale, P., Infarinato, F., Nasr, N., Mountain, G., Hermens, H.J., Stienen, A.H. & Buurke, J.H. 2015. Feasibility study into self-administered training at home using an arm and hand device with motivational gaming environment in chronic stroke. Journal of neuroengineering and rehabilitation, 12, 1.
- Nilsson, M., Ingvast, J., Wikander, J. & Von Holst, H. 2012. The Soft Extra Muscle system for improving the grasping capability in neurological rehabilitation. In Biomedical Engineering and Sciences (IECBES), 2012 IEEE EMBS Conference, 412-417.
- Polygerinos, P., Galloway, K.C., Sanan, S., Herman, M. & Walsh, C.J. EMG controlled soft robotic glove for assistance during activities of daily living. Rehabilitation Robotics (ICORR), 2015 IEEE International Conference on, 2015. IEEE, 55-60.
- Prange, G., Smulders, L., Van Wijngaarden, J., Lijbers, G., Nijenhuis, S., Veltink, P., Buurke, J. & Stienen, A. User requirements for assistance of the supporting hand in bimanual daily activities via a robotic glove for severely affected stroke patients. Rehabilitation Robotics (ICORR), 2015 IEEE International Conference on, 2015. IEEE, 357-361.
- Prasad, S.M., Maniar, H. S., Soper, N.J., Damiano, R.J. & Klingensmith, M. E. 2002. The effect of robotic assistance on learning curves for basic laparoscopic skills. The American journal of surgery, 183, 702-707.
- Radder, B., Kottink, A.I.R., Van Der Vaart, N., Oosting, D., Buurke, J.H., Nijenhuis, S.M., ... & Rietman, J.S. 2015. User-centred input for a wearable soft-robotic glove supporting hand function in daily life. 2015 IEEE International Conference on Rehabilitation Robotics (ICORR), 502-507.
- Ranganathan, V. K., Siemionow, V., Sahgal, V. & Yue, G. H. 2001. Effects of Aging on Hand Function. Journal of the American Geriatrics Society, 49, 1478-1484.
- Shiffman, L.M. 1992. Effects of aging on adult hand function. American Journal of Occupational Therapy, 46, 785-792.
Paper Citation
in Harvard Style
Radder B., Prange-Lasonder G., Kottink A., Gaasbeek L., Holmberg J., Meyer T., Buurke J. and Rietman J. (2016). Preliminary Findings of Feasibility of a Wearable Soft-robotic Glove Supporting Impaired Hand Function in Daily Life - A Soft-robotic Glove Supporting ADL of Elderly People . In Proceedings of the International Conference on Information and Communication Technologies for Ageing Well and e-Health - Volume 1: ICT4AWE, (ICT4AGEINGWELL 2016) ISBN 978-989-758-180-9, pages 180-185. DOI: 10.5220/0005879001800185
in Bibtex Style
@conference{ict4awe16,
author={B. Radder and G. B. Prange-Lasonder and A. I. R. Kottink and L. Gaasbeek and J. Holmberg and T. Meyer and J. H. Buurke and J. S. Rietman},
title={Preliminary Findings of Feasibility of a Wearable Soft-robotic Glove Supporting Impaired Hand Function in Daily Life - A Soft-robotic Glove Supporting ADL of Elderly People},
booktitle={Proceedings of the International Conference on Information and Communication Technologies for Ageing Well and e-Health - Volume 1: ICT4AWE, (ICT4AGEINGWELL 2016)},
year={2016},
pages={180-185},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0005879001800185},
isbn={978-989-758-180-9},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Information and Communication Technologies for Ageing Well and e-Health - Volume 1: ICT4AWE, (ICT4AGEINGWELL 2016)
TI - Preliminary Findings of Feasibility of a Wearable Soft-robotic Glove Supporting Impaired Hand Function in Daily Life - A Soft-robotic Glove Supporting ADL of Elderly People
SN - 978-989-758-180-9
AU - Radder B.
AU - Prange-Lasonder G.
AU - Kottink A.
AU - Gaasbeek L.
AU - Holmberg J.
AU - Meyer T.
AU - Buurke J.
AU - Rietman J.
PY - 2016
SP - 180
EP - 185
DO - 10.5220/0005879001800185