in-vitro Assessment of Expanded-Polytetrafluoroethylene Stentless Tri-leaflet Valve Prosthesis for Aortic Valve Replacement
Guangyu Zhu, Masakazu Nakao, Qi Yuan, Joon Hock Yeo
2017
Abstract
Truly stentless polymeric valve prosthesis can be a viable alternative for aortic valve replacement (AVR). In the present paper, the dynamic and hemodynamic performance of a novel designed expanded-polytetrafluoroethylene (ePTFE) stentless tri-leaflet valve was assessed experimentally. The in-vitro tests were performed under time-varying physiological pressure by using the Vivitro pulse duplicator. A high-speed camera, a flow meter, and pressure transducers were utilized to evaluate the dynamic leaflet behaviours and coaptation parameters. The maximum effective orifice area, mean pressure gradient, regurgitant volume, leakage volume and energy loss of the stentless ePTFE tri-leaflet valve are 2.86 cm2, 9.89 mmHg, 7.09 ml/beat, 2.81 ml/beat and 129.03 mJ, respectively. The results of the current study may provide a viable option for the future clinical application.
References
- Bernacca, G.M. et al., 2002. Hydrodynamic function of polyurethane prosthetic heart valves: influences of Young's modulus and leaflet thickness. Biomaterials, 23(1), pp.45-50.
- Brancaccio, G. et al., 2014. The Ross procedure in patients aged less than 18 years: the midterm results. The Journal of thoracic and cardiovascular surgery, 147(1), pp.383-388.
- Burriesci, G. et al., 2010. Design of a novel polymeric heart valve. Journal of medical engineering and technology, 34(1), pp.7-22.
- Claiborne, T.E. et al., 2013. In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve. Journal of biomechanical engineering, 135(2), p.021021.
- ISO 5840:2005 - Cardiovascular implants -- Cardiac valve prostheses.
- Lower, D. et al., 1960. Autotransplantation of the pulmonic valve into the aorta. The Journal of Thoracic and Cardiovascular Surgery, 39, pp.680-687.
- Mazzitelli, D. et al., 1998. Aortic valve replacement in children: are we on the right track?. European Journal of Cardio-Thoracic Suregery, 13(5), pp.565-571.
- Miyazaki, T. et al., 2011. Expanded polytetrafluoroethylene conduits and patches with bulging sinuses and fanshaped valves in right ventricular outflow tract reconstruction: Multicenter study in Japan. The Journal of thoracic and cardiovascular surgery, 142(5), pp.1122-1129.
- Miyazaki, T. et al., 2007. Expanded polytetrafluoroethylene valved conduit and patch with bulging sinuses in right ventricular outflow tract reconstruction. The Journal of thoracic and cardiovascular surgery, 134(2), pp.327- 332.
- Oury, J.H. et al., 1998. The Ross procedure: Current registry results. Annals of Thoracic Surgery, 66(6), pp.S162-S165.
- Roe, B.B. and Moore, D., 1958. Design and fabrication of prosthetic valves. Experimental medicine and surgery, 16(2-3), pp.177-182.
- Ross, D., 1967. Replacement of aortic and mitral valves with a pulmonary autograft. The Lancet, 290(7523), pp.956-958.
- Sachweh, J.S. and Daebritz, S.H., 2006. Novel “biomechanical” polymeric valve prostheses with special design for aortic and mitral position: a future option for pediatric patients?. ASAIO journal, 52(5), pp.575-580.
- Talwar, S. et al., 2012. Aortic valve replacement with biological substitutes in children. Asian cardiovascular and thoracic annals, 20(5), pp.518-524.
Paper Citation
in Harvard Style
Zhu G., Nakao M., Yuan Q. and Yeo J. (2017). in-vitro Assessment of Expanded-Polytetrafluoroethylene Stentless Tri-leaflet Valve Prosthesis for Aortic Valve Replacement . In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2017) ISBN 978-989-758-216-5, pages 186-189. DOI: 10.5220/0006184401860189
in Bibtex Style
@conference{biodevices17,
author={Guangyu Zhu and Masakazu Nakao and Qi Yuan and Joon Hock Yeo},
title={in-vitro Assessment of Expanded-Polytetrafluoroethylene Stentless Tri-leaflet Valve Prosthesis for Aortic Valve Replacement},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2017)},
year={2017},
pages={186-189},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006184401860189},
isbn={978-989-758-216-5},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2017)
TI - in-vitro Assessment of Expanded-Polytetrafluoroethylene Stentless Tri-leaflet Valve Prosthesis for Aortic Valve Replacement
SN - 978-989-758-216-5
AU - Zhu G.
AU - Nakao M.
AU - Yuan Q.
AU - Yeo J.
PY - 2017
SP - 186
EP - 189
DO - 10.5220/0006184401860189