Iterative Adaptive Sparse Sampling Method for Magnetic Resonance Imaging
Giuseppe Placidi, Luigi Cinque, Andrea Petracca, Matteo Polsinelli, Matteo Spezialetti
2017
Abstract
Magnetic Resonance Imaging (MRI) represents a major imaging modality for its low invasiveness and for its property to be used in real-time and functional applications. The acquisition of radial directions is often used but a complete examination always requires long acquisition times. The only way to reduce acquisition time is undersampling. We present an iterative adaptive acquisition method (AAM) for radial sampling/reconstruction MRI that uses the information collected during the sequential acquisition process on the inherent structure of the underlying image for calculating the following most informative directions. A full description of AAM is furnished and some experimental results are reported; a comparison between AAM and weighted compressed sensing (CS) strategy is performed on numerical data. The results demonstrate that AAM converges faster than CS and that it has a good termination criterion for the acquisition process.
References
- Arias-Castro, E., Candes, E., and Davenport, M. (2013). On the fundamental limits of adaptive sensing. IEEE Transactions on Information Theory, 59(1):472-481.
- Bernstein, M., King, K., and Zhou, X. (2004). Handbook of MRI Pulse Sequences. Elsevier Academic Press.
- Brooks, R. and Di Chiro, G. (1976). Principles of computer assisted tomography (cat) in radiographic and radioisotopic imaging. Physics in Medicine and Biology, 21(5):689-732.
- Candes, E., Romberg, J., and Tao, T. (2006). Robust uncertainty principles: Exact signal reconstruction from highly incomplete frequency information. IEEE Transactions on Information Theory, 52(2):489-509.
- Chen, C. and Huang, J. (2012). Compressive sensing mri with wavelet tree sparsity. In Advances in Neural Information Processing Systems, pages 1124-1132.
- Ciancarella, L., Avola, D., Marcucci, E., and Placidi, G. (2012). A hibrid sampling strategy for sparse magnetic resonance imaging. In Computational Modelling of Objects Represented in Images. Fundamentals, Methods and Applications, pages 285-289, Boca Raton - USA. CRC Press, Taylor & Francis Group.
- Donoho, D. (2006). Compressed sensing. IEEE Transactions on Information Theory, 52(4):1289-1306.
- Edelstein, W., Hutchison, J., Johnson, G., and Redpath, T. (1980). Spin warp nmr imaging and applications to human whole-body imaging. Physics in Medicine and Biology, 25(4):751-756.
- Gonzalez, R. and Woods, R. (2007). Digital Image Processing (3rd Edition). Pearson.
- Jackson, J., Meyer, C., Nishimura, D., and Macovski, A. (1991). Selection of a convolution function for fourier inversion using gridding [computerised tomography application]. IEEE Transactions on Medical Imaging, 10(3):473-478.
- Lauterbur, P. (1973). Image formation by induced local interactions: examples employing nuclear magnetic resonance. Nature, 242(5394):190-191.
- Lustig, M., Donoho, D., and Pauly, J. (2007). Sparse mri: The application of compressed sensing for rapid mr imaging. Magnetic Resonance in Medicine, 58(6):1182-1195.
- Magnusson, M., Leinhard, O., Brynolfsson, P., Thyr, P., and Lundberg, P. (2010). 3d magnetic resonance imaging of the human brain - novel radial sampling, filtering and reconstruction. In 12th IASTED International Conference on Signal and Image Processing (SIP 2010). ACTA Press.
- Meyer, C. (1998). Spiral echo-planar imaging, pages 633- 658. Springer Berlin Heidelberg.
- O'Sullivan, J. (1985). A fast sinc function gridding algorithm for fourier inversion in computer tomography. IEEE Transactions on Medical Imaging, 4(4):200- 207.
- Placidi, G. (2009a). Adaptive compression algorithm from projections: Application on medical greyscale images. Computers in biology and medicine, 39:993- 999.
- Placidi, G. (2009b). Constrained reconstruction for sparse magnetic resonance imaging. In World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany, volume 25/4, pages 89-92, Berlin Heidelberg - DEU. Springer.
- Placidi, G. (2010). Circular acquisition to define the minimum set of projections for optimal mri reconstruction. Lecture notes in computer science, 6026:254-262.
- Placidi, G. (2012). MRI: essentials for innovative technologies. CRC Press, Taylor & Francis Group, Boca Raton - USA.
- Placidi, G. (2014). Recent advances in acquisition/reconstruction algorithms for undersampled magnetic resonance imaging. Journal of biomedical engineering and medical imaging, 1:59-78.
- Placidi, G., Alecci, M., Colacicchi, S., and Sotgiu, A. (1998). Fourier reconstruction as a valid alternative to filtered back projection in iterative applications: Implementation of fourier spectral spatial epr imaging. Journal of Magnetic Resonance, 134(2):280-286.
- Placidi, G., Alecci, M., and Sotgiu, A. (1995). Theory of adaptive acquisition method for image reconstruction from projections and application to epr imaging. Journal of magnetic resonance. Series A, 108:50-57.
- Placidi, G., Alecci, M., and Sotgiu, A. (2000). Omegaspace adaptive acquisition technique for magnetic resonance imaging from projections. Journal of Magnetic Resonance, 143(1):197-207.
- Placidi, G., Avola, D., Cinque, L., Macchiarelli, G., Petracca, A., and Spezialetti, M. (2014). Adaptive sampling and non linear reconstruction for cardiac magnetic resonance imaging. In Computational Modeling of Objects Presented in Images Fundamentals, Methods, and Applications, volume 8641, pages 24-35.
- Placidi, G. and Sotgiu, A. (2004). A novel restoration algorithm for reduction of undersampling artefacts from magnetic resonance images. Magnetic resonance imaging, 22:1279-1287.
- Sung, K. and Hargreaves, B. (2013). High-frequency subband compressed sensing mri using quadruplet sampling. Magnetic Resonance in Medicine, 70(5):1306- 1318.
- Wang, Z. and Arce, G. (2010). Variable density compressed image sampling. IEEE Transactions on Image Processing, 19(1):264-270.
Paper Citation
in Harvard Style
Placidi G., Cinque L., Petracca A., Polsinelli M. and Spezialetti M. (2017). Iterative Adaptive Sparse Sampling Method for Magnetic Resonance Imaging . In Proceedings of the 6th International Conference on Pattern Recognition Applications and Methods - Volume 1: ICPRAM, ISBN 978-989-758-222-6, pages 510-518. DOI: 10.5220/0006199105100518
in Bibtex Style
@conference{icpram17,
author={Giuseppe Placidi and Luigi Cinque and Andrea Petracca and Matteo Polsinelli and Matteo Spezialetti},
title={Iterative Adaptive Sparse Sampling Method for Magnetic Resonance Imaging},
booktitle={Proceedings of the 6th International Conference on Pattern Recognition Applications and Methods - Volume 1: ICPRAM,},
year={2017},
pages={510-518},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006199105100518},
isbn={978-989-758-222-6},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 6th International Conference on Pattern Recognition Applications and Methods - Volume 1: ICPRAM,
TI - Iterative Adaptive Sparse Sampling Method for Magnetic Resonance Imaging
SN - 978-989-758-222-6
AU - Placidi G.
AU - Cinque L.
AU - Petracca A.
AU - Polsinelli M.
AU - Spezialetti M.
PY - 2017
SP - 510
EP - 518
DO - 10.5220/0006199105100518