Consideration of the Human Factor in the Design and Development of a New Medical Device: Example of a Device to Assist Manual Ventilation
L. Pazart, F. S. Sall, A. De Luca, A. Vivot-Pugin, S. Pili-Floury, G. Capellier, A. Khoury
2017
Abstract
The human factor is often critical in the performance and safety of a large number of medical devices. To minimize risks to users and patients, health authorities have reinforced their requirements including human factors and usability testing during the development of new technologies. Human factors engineering (HFE) is an interdisciplinary approach to evaluating and improving use safety, efficiency, and robustness of work systems. The new device should be tested to show its safety and effectiveness for the intended users, uses and use environments. In order to fulfill these regulatory requirements, international standards suggest implementing the User Centered Design process during the technology design and development lifecycle. We would like to present here a case study of a HFE plan about an ongoing medical device development in order to illustrate how to practically process; then we will present some more general considerations on HFE development for medical devices. Manual ventilation is an essential step in the resuscitation of respiratory distressed patients. It must be carried out adequately so as not to worsen patient’s condition. This technique has its advantages but also risks such as excessive insufflated pressures resulting in pulmonary barotrauma and gastric insufflation. In fact, many studies have shown that manual ventilation practices are far above recommended guidelines. Several solutions have been proposed by some manufacturers to achieve better control over manual ventilation parameters, but none has really convinced the medical community to date. Thus we propose to develop a new technology guided by a well adapted HFE. We first carried out a study with the existing material to observe the practices of 140 professionals in several clinical situations on an artificial lung, allowing to reproduce situations of respiratory deficiency and to record the parameters. The preliminary results showed a fairly low rate of manual ventilation performance with high ventilation rates, confirming the fragmented data of the literature on the subject. Thus, with the help of a local company, Polycaptil, we developed a new medical device, with an algorithm for real-time analysis on the basis of the 54,000 ventilatory cycles recorded during our study. After the prototype reached the technical objectives and demonstrated good reliability, we organized a usability validation test with 40 end-users. After the ventilation tests, participants were asked to complete a survey on the ease of use of the prototype, including the ergonomics of the entire system, the human-machine interface and its main functions. Both usability surveys provided important guidance for the development of the final device. Finally, the human factors validation testing should be realized during a prospective clinical trial of the first use in humans of a device for monitoring manual ventilation. The human factor is one of the most differentiating characteristics of the development of a medical device compared to the development plan of a drug. Specific methodologies are being developed and adapted tools have been set up. Based on our example, methods and purposes of HFE evaluation will be described at every stage of the device development lifecycle in order to sensitizing designers of new technologies.
References
- Jans A, Plogmann S, Radermacher K. 2016 Humancentered risk management for medical devices - new methods and tools. Biomedical Engineering / Biomedizinische Technik. Volume 61, Issue 2, Pages 165-181, ISSN (Online) 1862-2'X, ISSN (Print) 0013-5585, DOI: 10.1515/bmt-2014-0124.
- Schertz JC, Saunders H, Hecker C, Lang B, Arriagada P. 2011 The redesigned follitropin alfa pen injector: results of the patient and nurse human factors usability testing. Expert Opin Drug Deliv. Sep;8(9):1111-20. doi: 10.1517/17425247.2011. 608350. Epub 2011 Aug 16.
- Ash D, 2007 Lessons from Epinal, Clin Oncol 19(8), 614- 5.
- Hauser RG, Kallinen L. 2004 Deaths associated with implantable cardioverter defibrillator failure and deactivation reported in the United States Food and Drug Administration Manufacturer and User Facility Device Experience Database. Heart Rhythm. Oct;1(4):399-405.
- British Standards Institution (BSI), 2016 The growing role of human factors and usability engineering for medical devices, white paper, http://www.bsigroup.com/enGB/medical-devices/resources/whitepapers, last access 11 February 2016.
- Xuanyue M, Pengli J, Longhao Z, Pujing Z, Ying C, Mingming Z. 2015 An Evaluation of the Effects of Human Factors and Ergonomics on Health Care and Patient Safety Practices: A Systematic Review. PLoS One.; 10(6): e0129948. doi: 10.1371/ journal.pone.0129948.
- FDA 2016 - Applying Human Factors and Usability Engineering to Medical Devices Guidance for Industry and Food and Drug Administration Staff Document issued on: February 3, 2016 http://www.fda.gov/downloads/MedicalDevices/Devic eRegulationandGuidance/GuidanceDocuments/UCM2 59760.pdf.
- European Parliament Council, 2007 Council Directive 2007/47/EC, http://eurlex.europa.eu/LexUriServ/LexUriServ.do?uri =OJ:L:2007:247:0021:0055:en:PDF, last access 11 February 2016.
- Human Factors and Ergonomics Society, 2016 Definitions of Human Factors and Ergonomics, http://www.hfes.org/Web/EducationalResources/HFE definitionsmain.html, last access 11 November 2016.
- International Electrotechnical Commission, 2007 Medical devices - Application of usability engineering to medical devices (Rep N° 62366), Geneva, International Electrotechnical Commission.
- Busko JM, Blackwell TH. 2006 Impact of a pressureresponsive flow-limiting valve on bag-valve-mask ventilation in an airway model. Can J Emerg Med 8 : 158-163.
- Elling R, Politis J. 1983 An evaluation of emergency medical technician's ability to use manual ventilation devices. Ann Emerg Med; 12 : 765-768.
- Martin PD, Cyna AM, Hunter WAH, Henry J, Rammaya GP. 1993 Training nursing staff in airway management for resuscitation. A clinical comparison of a facemask and laryngeal mask. Anaesthesia; 48 : 133-137.
- Wynne G, Marteau TM, Johnson M, Whiteley CA, Evance TR. 1987 Inability of trained nurses to perform basic life support. Br Med J (Clin Res Ed); 294 : 1198- 1199.
- Bergrath S, Rossaint R, Biermann H, Skorning M, Beckers SK, Rörtgen D, Brokmann JC, Flege C, Fitzner C, Czaplik M. 2012 Comparison of manually triggered ventilation and bag-valve-mask ventilation during cardiopulmonary resuscitation in a manikin model. Resuscitation; 83 : 488-493.
- Von Goedecke A, Bowden K, Wenzel V, Keller C, Gabrielli A. 2005 Effects of decreasing inspiratory times during simulated bag-valve-mask ventilation. Resuscitation; 64 : 321-325.
- Cooper JA, Cooper JD, Cooper JM. 2006 Cardiopulmonary Resuscitation: History, Current Practice, and Future Direction. Circulation; 114 : 2839-2849.
- Khoury A, Sall FS, De Luca A, Pugin A, Pili-Floury S, Pazart L, Capellier G. 2016 Evaluation of Bag-ValveMask Ventilation in Manikin Studies: What Are the Current Limitations? Biomed Res Int. 4521767. doi: 10.1155/2016/4521767.
- Bowman TA, Paget-Brown A, Carroll J, Gurka MJ, Kattwinkel J. 2012 Sensing and responding to compliance changes during manual ventilation using a lung model : can we teach healthcare providers to improve? J Pediatr; 160 : 372-376.
- Gawron VJ, Drury CG, Fairbanks RJ, Berger RC. 2006 Medical error and human factors engineering: where are we now? Am J Med Qual. Jan-Feb;21(1):57-67.
- Gosbee J. 2002 Human factors engineering and patient safety. Quality and safety in health care., 11: 352-354. 10.1136/qhc.11.4.352.
- Institute for Healthcare Improvement Failure Modes and Effects Analysis (FMEA) tool. 2011 Available from: http://www.ihi.org/knowledge/Pages/Tools/FailureMo desandEffectsAnalysisTool.aspx. (Last accessed 28 May 2014)
- Association for the Advancement of Medical Instrumentation. AAMI TIR49:2013. Design of training and instructional materials for medical devices used in non-clinical environments. Association for the Advancement of Medical Instrumentation; Arlington, VA.
Paper Citation
in Harvard Style
Pazart L., Sall F., De Luca A., Vivot-Pugin A., Pili-Floury S., Capellier G. and Khoury A. (2017). Consideration of the Human Factor in the Design and Development of a New Medical Device: Example of a Device to Assist Manual Ventilation . In Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2017) ISBN 978-989-758-216-5, pages 215-223. DOI: 10.5220/0006250102150223
in Bibtex Style
@conference{biodevices17,
author={L. Pazart and F. S. Sall and A. De Luca and A. Vivot-Pugin and S. Pili-Floury and G. Capellier and A. Khoury},
title={Consideration of the Human Factor in the Design and Development of a New Medical Device: Example of a Device to Assist Manual Ventilation},
booktitle={Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2017)},
year={2017},
pages={215-223},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0006250102150223},
isbn={978-989-758-216-5},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 10th International Joint Conference on Biomedical Engineering Systems and Technologies - Volume 1: BIODEVICES, (BIOSTEC 2017)
TI - Consideration of the Human Factor in the Design and Development of a New Medical Device: Example of a Device to Assist Manual Ventilation
SN - 978-989-758-216-5
AU - Pazart L.
AU - Sall F.
AU - De Luca A.
AU - Vivot-Pugin A.
AU - Pili-Floury S.
AU - Capellier G.
AU - Khoury A.
PY - 2017
SP - 215
EP - 223
DO - 10.5220/0006250102150223