will be used to perform the hip and knee bending
exercise with leg patients.
ACKNOWLEDGEMENTS
This research was supported by Basic Science
Research Program through the National Research
Foundation of Korea (NRF) funded by the
Ministry of Science, ICT and Future Planning
(No. 2015R1A2A2A01002952).
REFERENCES
Yu, H., Huang, S., Chen,G., Thakor, N., 2013, Control
design of a novel compliant actuator for rehabilitation
robots, Mechatronics, No. 23, pp. 1072-1083.
Akdogan, E., Adli, M. A., 2011, The design and control a
therapeutic exercise robot for lower limb
rehabilitation: Physiotherabot, Mechatronics, No.21,
pp. 509-522.
Zhang, J. F., Dong, Y. M., Yang, C. J., Geng, Y., Chen, Y.
Yang, T., 2010, 5-Link model based gait trajectory
adaption control strategies of the gait rehabilitation
exoskeleton for post-stroke patients, Mechatronics,
No. 20, pp. 368-376, 2010.
Pennycott, A., Hunt, K. J., Jack, L. P., Perret, C.,
Kakebeeke, T. H., 2009, Estimation and volitional
feedback control of active work rate during robot-
assisted gait, Control Engineering Pracrice, No. 17,
pp. 322-328.
Malcolm, P., Fiers, P., Segers, V., Caekenberghe, I. V.,
Lenoir, M., Clercq, D. D., 2009, Experimental study
on the role of the ankle push off in the walk-to-run
transition by means of a owered ankle-foot-
exoskeleton, Gait & Posture, No. 30, pp. 322-327.
Wu, M., Hornby, T. G., Landry, J. M., Roth, H., Schmit, B.
D., 2011, A cable-driven locomotor training system
for restoration of gait in human SCI, Gait & Posture,
No. 33, pp. 256-260.
Martins, M. M., Santos, C. P., Anselmo, F. N., Ramon C.,
2012, Assistive mobility devices focusing on Smart
Walkers: Classification and review, Robotics and
Autonomous Systems, No. 60, pp. 548-562.
Karavas, N., Ajoudani, A., Tsagarakis, N., Saglia, J.,
Bicchi, A., Caldwell, D., 2014, Tele-impedance based
assistive control for a compliant knee exoskeleton,
Robotics and Autonomous Systems, Vol. 73, No. 2015,
pp. 78-90.
Rajasekaran, V., Aranda, J., Casals, A., Pons, J. L., 2014,
An adaptive control strategy for postural stability
using a wearable robot, Robotics and Autonomous
Systems, Vol. 73, No. 2015, pp. 16-23.
Mohammeda, S., Huoa, W., Huang, J., Rifai, H., Amirat,
Y., 2014, Nonlinear disturbance observer based sliding
mode control of a human-driven knee joint orthosis,
Robotics and Autonomous Systems, Vol. 75, No. 2016,
pp. 41-49.
Asbeck, A. T., Schmidt, K., Walsh, C. J., 2014, Soft
exosuit for hip assistance, Robotics and Autonomous
Systems, Vol. 73, No. 2015, pp. 102-110.
Nagai, K., Ito, Y., Yazaki, M., Higuchi, K., Abe, S., 2004,
Development of a small Six-component force/torque
sensor based on the double-cross structure, Adv.
Robot., Vol.22, No.3, pp. 361-369.
Song, A., Wu, J., Qin, G., Huang, W., 2007, A novel self-
decoupled four degree-of-freedom wrist force/torque
nsor, Measurement, Vol. 40, pp. 883-891.
Kim, H.M., Yoon, J.W., Kim, G.S., 2012, Development of
a six-axis force/moment sensor for a spherical-type
finger force measuring system, IET Science,
Measurement and Technology, Vol. 6, pp. 96-104.
Kim G. S., 2008, Development of 6-axis force/moment
sensor for a humanoid robot's foot," IET Science,
Measurement & Technology, Vol. 2, pp.122-133.