H
10 (92.11) 12.25 0.5723 10.82
11 97.33 (3.34) 0.2160 10.93
12 82.67 11.86 (0.403) 11.00
13 (94.74) 3.74 0.1924 10.62
14 80.52 (13.48) 0.4415 10.72
15 82.67 11.86 (0.403) 11.00
Table 6 showed the analysis results of the target
condition and the best condition obtained by
Taguchi analysis. According to the target conditions,
three experiments were carried out and the results
were shown in Table 8. It was found that No. 10, its
E, R
A
and K
G
a, were all up to standard, indicating
that the target conditions is obtained in here. In
addition, the best condition confirmation showed
that No. 13 was not reached the best, while the Nos.
14 and 15 all reached the best as compared with
Taghchi experiments listed in Table 4. From both
analyses, it was hard to obtain higher E and K
G
a
simultaneously. Therefore, how to use effective
experimental design to obtain the desired conditions
became significant. In this study, the condition of
A1B1C2D3(No. 10) can satisfy not only a higher E,
but also a higher K
G
a.
4 CONCLUSIONS
A continuous bubble-column scrubber was
successfully used to investigate the process variables
on the absorption efficiency, absorption rate, and
overall mass transfer coefficient. Under Taguchi
experimental design, a total of 9 runs were carried
out in here. It was found that the system could reach
a steady state after 20 minutes, while the final pH
was in the range of 10.16-11.25, depending on the
operating condition. In addition, the absorption
efficiency was found to be in the range of 65.79-
98.7%; the absorption rate was in
4
1054.3
-
Lsmol
/109.13
4
; and the overall mass
transfer coefficient was in 0.1743-0.3950 1/s. From
Taguchi analysis for target and the best modes, it
was found that the gas flow rate (B) was major
factors influencing the outcome data, while the
influence of the temperature in the column (C) was
the minor. In addition, the target condition was
found to be A1B1C2D3. Through the confirmation
of target conditions, it was known that the E
(92.11%), R
A
(1.225x10
-3
mol/s L) and K
G
a (0.5723
s
-1
) all reached the set target value.
REFERENCES
Adeosun A, Goetheer N E H, Abu-Zahra M R M 2013
Absorption of CO
2 by Amine Blends Solution: An
Experimental Evaluation International Journal of
Engineering And Science 3 12
Aroonwilas A, Veawab A 2009 Integration of CO2
capture unit using blended MEA-AMP solution into
coal-fired power plants Energy Procedia 1 4315
Aroonwilas A, Veawab A, Tontiwachwuthikul P 1999
Behavior of mass-transfer coefficient of structured
packings in CO
2 absorbers with chemical reactions
1999 Ind Eng. Chem. Res. 38 2044
Chen P C, Luo Y X, Cai P W 2015 Capture of Carbon
Dioxide Using Monoethanolamine in a Bubble-
Column Scrubber Chemical Engineering &
Technology 38 274
Chen P C, Shi W, Du R, Chen V 2008 Scrubbing of CO2
green-house gases, accompanied by precipitation in a
continuous bubble-column scrubber Ind. Eng. Chem.
Res. 47 6336
Choi W J, Seo J B, Jang S Y, Jung J H, Oh K J 2009
Removal characteristics of CO2 using aqueous
MEA/AMP solutions in the absorption and
regeneration process Journal of Environmcntal
Scicnccs 21 907
Fan L S 1989 Gas-liquid-solid fluidization engineering
Butterworths USA Ch. 9 600
Gomes J, Santos S, Bordado J 2015 Choosing amine
based absorbents for CO2 capture Environmental
Technology 36 19
Hvalec M, Gorsek A, Glavic P 2004 Experimental design
of crystallization processes using Taguchi method Acta
Chim. Slov. 51 245
Idem R, Wilson M, Tontiwachwuthikul P, Chakma A,
Veawab A, Aroonwilas A, Gelowitz D 2006 Pilot plant
studies of the CO2 capture perforance of aqueous MEA
and Mixed MEA/MDEA solvents at the University of
Regina CO2 capture technology development plant and
boundary dam CO capture demonstration plant Ind.
Eng. Chem. Res. 45 2414
Khan A A, Halder G N, Saha A K 2015 Carbon dioxide
capture characteristics from flue gas using aqueous 2-
amino-2-methyl-1-propanol (AMP) and
monoethanolamine (MEA) solutions in packed bed
absorption and regeneration columns Int. J. Greenh.
Gas Control 32 15