Straight-Reading Electric Measurement Technique for Polymer
Flooding Injection Wells
Shaogong Zhu
1
, Dekui Xu
1
Wangfu Zhou
1
Chongjiang Liu
1
Xingliang Song
1
Kuilong Li
1
Haicheng Li
1
Fuming Liang
1
Guanglei Gao
1
Jundong Tang
1
Xiaofeng Li
1
Yu Han
1
and
Jianyun Li
1
1
Daqing Oilfield Production Engineering & Research Institute, Daqing, China
Keywords: Polymer flooding; flow test; test and adjust simultaneousy; mechatronic control technology.
Abstract: In Daqing oilfield, the polymer flooding wells with more than 3 layers have reached 50%, For conventional
steel wire fishing and layer flow test method, the working is cumbersome in operation, heavy in workload
and long in measuring and adjusting time. To this problem conducted a polymer flooding injection straight-
reading electric measuring technology research. With advanced mechatronic control technology, using test
and adjust simultaneousy methods, real-time monitoring of parameters such as docking status, flow rate,
pressure, and temperature during the polymer flooding injection wells layer flow test. The result shows that
3-5 layer single-well measurement efficiency has improved by more than 2 times. Polymer flooding
injection straight-reading electric measuring technology achieved the goal of completing the multi-layer
flow deploy with once down the well, test efficiency and test pass rate has significantly improved and has a
good promotion and application prospects.
1 INTRODUCTION
Daqing oilfield is a large-scale deposited sand oil
field, belongs to the heterogeneous reservoir
sandstone reservoir, with the deepening of the
polymer flooding, the displacement gradually shift
to low permeability layers, however, there are many
vertical layers in the oil layer, strong heterogeneity,
serious inter-layer interference, and difficulty in
stratified testing[1-3]. Polymer flooding injection
Wells from 2007 to 2017 increase at an annual rate
of 1000, the test workload increased by more than
4000 Wells, in order to ensure the normal injection,
need to increase the test equipment and labor costs
about 10 million yuan each year, at the same time,
the traditional testing technology uses matching
method, need to repeatedly fishing plugs to replace
throttling cores, labor intensity is bigger but test
efficiency is lower[4-5]. In order to improve the test
efficiency and the injection rate, the technology of
straight-reading electric measurement for polymer
flooding is developed[6].
2 COLUMN SELECTION
In recent years, Daqing oilfield development various
polymer flooding dispensation technologies, such as
cylindrical structure, annular decompression groove,
spindle pole, improved spindle pole and streamlined
step-down, in order to determine the best injection
process as the base string of polymer flooding
straight--reading electric measurement, comparing
the five dispensing columns used in the oilfield.
2.1 Indoor Comparison Evaluation
First of all, five in-house dispensing tools were
tested for indoor fishing and hydraulic performance
evaluation, the results shows: Streamlined step-
down dispensing tool has the highest fishing success
rate, the highest throttling pressure difference at the
same flow rate and the lowest sticking loss rate.
2.2 Field Comparison and Evaluation
For comprehensive contrast polymer injection tools,
has conducted field comparison of hydraulic
characteristics, mainly selected the larger application
streamlined step-down groove, cone spindle pole,
spindle pole three kinds of tools. When the flow rate
is 60m
3
/d, the cone spindle pole has lower throttling
pressure difference than streamlined step-down
groove. And the spindle (4 balls/140mm) is 52mm
longer than the streamlined step-down groove (8
slots/88mm), but the throttle pressure difference is
0.21MPa lower than streamlined step-down groove.
By contrast, the streamlined step-down groove has
good performance .
In comparison of field sticking loss rate, cone
spindle pole have a higher rate of sticking loss, and
there is a linear relationship between the sticking
loss and the flow rate of the spindle pole, the
sticking loss increases with the increase of the flow
rate. The sticking loss of the streamlined step-down
groove increases gradually with the increase of flow,
and finally tends to be stable .
Considering indoor and field contrast,
streamlined step-down groove structure points
injection tools with high throttle pressure difference,
low viscosity loss, measurement technology is fully
compatible with water injection, the column the
technical advantages such as can simultaneously
meet the need for flooding of different injection
media.
2.3 Column Setting
Comparing the test of polymer flooding points
injection column, select streamlined step-down
groove structure corresponds to the integration
points separate process for polymer flooding
injection Wells straight--reading of electric
measurement technology of the column, the process
is based on the interval property selection pressure
regulator or molecular weight regulator. In low
permeability reservoirs, Low molecular weight
regulators are used to reduce polymer molecular
weight, increase oil layer degree of use and volume
of exposure[7-9].
The whole process integration of separate
injection technology field application of more than
6000 Wells, after layered injection, compared with
normal polymer separate injection Wells, Oil layer
use are improved, using layer increased from 68.2%
to 73.9%, the use of thickness ratio from 73.9% to
80.9%. At the same time, the pipe column is
compatible with the water, it also can meet the
requirements of subsequent water flooding, and
reduces the cost.
3 POLYMER FLOODING WELL
STRAIGHT-READING
ELECTRIC MEASUREMENT
TECHNOLOGY
Relying on the integration of the whole process of
technology column, designed the polymer flooding
straight-reading electric measurement technology,
mainly including ground control system, straight-
reading electric measuring instrument, adjustable
plug, cable winch system(as shown in figure 1).
cable winch system
straight-reading electric
measurin
g
instrument
adjustable
ground control system
Figure 1: Structure diagram of polymer flooding well
straight-reading electric measurement technology.
3.1 Process Principle
First, in polymer flooding injection wells into the
whole process of injection column, according to the
requirement of the solution set the polymer flooding
adjustable pressure plug or adjustable molecular
plug under the corresponding layer, and then uses
the steel cable with straight- reading meter to the
purpose layer, then docking with adjustable pressure
plug or adjustable molecular plug, through adjusting
the plug slot number or nozzle to control the single
flow rate, molecular weight, until meet the
requirements of injection allocation scheme, which
can realize the continuous adjustable, quantitative
control and real-time monitoring, to improve the
efficiency of the layered testing.
3.2 Control System
The control system is composed of computer and
power supply system. The whole system has
functions such as flow protection, power supply
conversion, cable voltage compensation, signal
processing, data acquisition and data
communication. When applications, ground control
part have a communication signals, to complete the
collection of flow, temperature and pressure, and
real-time display and control the down hole working
conditions of the instruments, which can realize data
admission control, data storage, report output and
parameters tuning, etc. (as shown in figure 2).
Figure 2: Structure diagram of ground control system.
3.3 Straight-Reading Electric Measuring
Instrument
Straight-reading electric measuring instrument
mainly by mechanical arm, the control part,
measuring parts, steering mechanism and so on, by
receiving the ground sends commands, adjusting
arm, release and adjustable plug docking, flow
testing adjustment, temperature, the stress state of
measurement and testing is done at the same. And
has the data signal modulation and demodulation
and transmission function (as shown in figure 3).
Figure 3: Physical drawing of the instrument.
3.4 Adjustable Plugging Device
The adjustable plug is the actuator of the straight-
reading electric measurement system, which is the
core part of the whole system. It is divided into two
types: adjustable partial pressure plug and adjustable
molecular plug.
3.4.1 Adjustable Partial Pressure Plug
From the design points of polymer flooding process
integration injection process pressure regulating
elements, use of non-newtonian fluid mechanics
theory and the flow field simulation software,
optimize the pressure regulating element structure
parameters, by adjusting the throttle element of
effective length, control single injection pressure,
achieves stepless adjustment of the first-level
dispensing tool from low pressure loss to high
pressure loss, to meet the needs of different
injection.
3.4.2 Adjustable Molecular Plug
The existing separation technology adopts single
water nozzle to adjust the molecular, and the
adjustment range is less than 30% when the flow
injection quantity (20-50m3/d) is lower, and when
the injection scheme is changed, it needs to be put
out the water mouth, which is cumbersome and
inefficient. New type adjustable molecular plug by
adjusting the number of nozzle to control the
polymer solution degree of shear, to achieve high
shear, low pressure loss, the continuous adjustable
molecular weight, the injection of polymer
molecular weight are best match of reservoir
permeability, maximize the effective use of low
permeable reservoirs.
3.5 Cable Winch System
To ensure the running of the measurement and
control system, developed a special cable winch
system, adopts the cylinder and the steel cable wire
roller double drum structure, steel wire used for plug
fishing, steel cable for test, two drum independent
operation, common hydraulic drive system,
operation convenient, flexible. The tension system
shows the cable tension in the process, which is
beneficial to construction operation and improve
cable life. Winch uses two kinds of mechanical and
electronic counting methods to realize
complementary advantages and ensure the accuracy
of depth.
4 FIELD APPLICATION
By the end of 2017, straight-reading electric
measurement technology in the application of more
than 300 Wells, 3-5 layer average single well test
time reduced to 2.5 days from 5.2 days, measuring
efficiency could be improved by more than 2 times.
It can be seen from the comparison with
conventional steel wire test, that the more the
number of single Wells layer is divided, the more
obvious the effect of electric measurement is, and
the efficiency of the well above 5 layers is nearly 3
times than normal test .
5 CONCLUSIONS
4.1 the straight-reading electric measurement
technology realizes the straight-reading test and the
continuous adjustment of layered flow, and the
measuring efficiency is more than twice than the
conventional process.
4.2 the polymer flooding straight-reading electric
measurement technology is compatible with the
water, and remains unchanged in the management of
the underground pipe column composition,
technology and test data.
4.3 by contrast, uniform polymer flooding
injection pipe column, expansion of polymer
flooding injection well straight-reading electric
measurement technology field application scale, and
improve the measurement and adjustment process.
4.4 the next step is to carry out the new type of
polymer flooding automatic measurement and
adjustment technology, so that the polymer flooding
can be developed intelligently and digitally.
REFERENCES
1. Liu,H, Yuan,T, Li,J,L. 1999. Polymer flooding
downhole single - tube injection technology,ACTA
Petrolei SINICA.
2. Zhou,J, Zhang X,Z, Ma,Z,H.2009.Tectonic frame
work and basin evolution in Northeast China, OiL &
Gasgeology.
3. Liu,H, Yan,J,W, Xue,F,Y, 2004. Status quo and future
development of production engineering at high water
cul stage in Daqing oilfield, Petroleum Geology &
Oilfield Development in Daqing.
4. Wan,R,F. 2000. Oil production engineering manual,
Oil industry press.
5. Jin,Y,S, Chao,H,Q, Zhao,S,Y. 2003, Oil production
geological engineering, Oil industry press.
6. Hu,B,Z. 2006, Stratified production technology of
heterogeneous multilayer sandstone oil field, Oil
industry press.
7. Pei,X,H, Liang,F,M, Cui,H,Q, et al.2006, Polymer
flooding eccentric quality sorting injection technology,
Petroleum Geology & Oilfield Development in
Daqing.
8. Chen,X,H, Duan,H. 2004, Principle and Application
of Separate Zone Polymer Flooding in Multi Zone
Reservoirs, Petroleum Geology & Oilfield
Development in Daqing.
9. Li,H,C. 2012, Overview of Separate Injection
Technique for Polymer Flooding in Daqing Oilfield,