processing, data acquisition and data
communication. When applications, ground control
part have a communication signals, to complete the
collection of flow, temperature and pressure, and
real-time display and control the down hole working
conditions of the instruments, which can realize data
admission control, data storage, report output and
parameters tuning, etc. (as shown in figure 2).
Figure 2: Structure diagram of ground control system.
3.3 Straight-Reading Electric Measuring
Instrument
Straight-reading electric measuring instrument
mainly by mechanical arm, the control part,
measuring parts, steering mechanism and so on, by
receiving the ground sends commands, adjusting
arm, release and adjustable plug docking, flow
testing adjustment, temperature, the stress state of
measurement and testing is done at the same. And
has the data signal modulation and demodulation
and transmission function (as shown in figure 3).
Figure 3: Physical drawing of the instrument.
3.4 Adjustable Plugging Device
The adjustable plug is the actuator of the straight-
reading electric measurement system, which is the
core part of the whole system. It is divided into two
types: adjustable partial pressure plug and adjustable
molecular plug.
3.4.1 Adjustable Partial Pressure Plug
From the design points of polymer flooding process
integration injection process pressure regulating
elements, use of non-newtonian fluid mechanics
theory and the flow field simulation software,
optimize the pressure regulating element structure
parameters, by adjusting the throttle element of
effective length, control single injection pressure,
achieves stepless adjustment of the first-level
dispensing tool from low pressure loss to high
pressure loss, to meet the needs of different
injection.
3.4.2 Adjustable Molecular Plug
The existing separation technology adopts single
water nozzle to adjust the molecular, and the
adjustment range is less than 30% when the flow
injection quantity (20-50m3/d) is lower, and when
the injection scheme is changed, it needs to be put
out the water mouth, which is cumbersome and
inefficient. New type adjustable molecular plug by
adjusting the number of nozzle to control the
polymer solution degree of shear, to achieve high
shear, low pressure loss, the continuous adjustable
molecular weight, the injection of polymer
molecular weight are best match of reservoir
permeability, maximize the effective use of low
permeable reservoirs.
3.5 Cable Winch System
To ensure the running of the measurement and
control system, developed a special cable winch
system, adopts the cylinder and the steel cable wire
roller double drum structure, steel wire used for plug
fishing, steel cable for test, two drum independent
operation, common hydraulic drive system,
operation convenient, flexible. The tension system
shows the cable tension in the process, which is
beneficial to construction operation and improve
cable life. Winch uses two kinds of mechanical and
electronic counting methods to realize
complementary advantages and ensure the accuracy
of depth.
4 FIELD APPLICATION
By the end of 2017, straight-reading electric
measurement technology in the application of more
than 300 Wells, 3-5 layer average single well test
time reduced to 2.5 days from 5.2 days, measuring
efficiency could be improved by more than 2 times.
It can be seen from the comparison with
conventional steel wire test, that the more the
number of single Wells layer is divided, the more
obvious the effect of electric measurement is, and