Methods of the Pulse Wave Velocity Estimation based on Pneumatic Blood Pressure Sensor Data and Synchronous ECG Records

V. E. Antsiperov, G. K. Mansurov, A. S. Bugaev

2020

Abstract

The article discusses a new method for diagnosing atherosclerosis with the help of a pneumatic blood pressure sensor recently developed by the authors. Since atherosclerosis is a progressive disease characterized by the deposition of cholesterol and certain fractions of lipoproteins on the walls of blood vessels, it is always accompanied by an increase in stiffness of the artery walls. One technique to assess arterial stiffness, is the measurement of arterial pulse wave velocity, that is the distance traveled by blood flow divided by the time it takes to travel that distance. So the direct method for estimating pulse wave velocity is to measure the transit time of a pulse wave between a pair of artery points by means, for example, of any tonometric sensors. In this connection the paper discusses the possibility of using a new type of sensors developed by the authors —– pneumatic sensors —to measure the pulse wave transit time. However, given the existing features of these sensors and, accordingly, the special features of pressure measurements, it was necessary to significantly modify the direct method for estimating pulse wave velocity. The main modification characterizing the new, indirect method consists in evaluating the delay of the pulse wave at the points of the artery with respect to some characteristic moment of a synchronous ECG (e.g. the time moment of R–peak, that corresponds to heart ventricles contractions). The details of this method and its modification in the form of a simplified single–point method of estimating pulse wave velocity form the main content of the work.

Download


Paper Citation


in Harvard Style

Antsiperov V., Mansurov G. and Bugaev A. (2020). Methods of the Pulse Wave Velocity Estimation based on Pneumatic Blood Pressure Sensor Data and Synchronous ECG Records. In Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - Volume 4: BIOSIGNALS; ISBN 978-989-758-398-8, SciTePress, pages 301-307. DOI: 10.5220/0009155303010307


in Bibtex Style

@conference{biosignals20,
author={V. E. Antsiperov and G. K. Mansurov and A. S. Bugaev},
title={Methods of the Pulse Wave Velocity Estimation based on Pneumatic Blood Pressure Sensor Data and Synchronous ECG Records},
booktitle={Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - Volume 4: BIOSIGNALS},
year={2020},
pages={301-307},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0009155303010307},
isbn={978-989-758-398-8},
}


in EndNote Style

TY - CONF

JO - Proceedings of the 13th International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC 2020) - Volume 4: BIOSIGNALS
TI - Methods of the Pulse Wave Velocity Estimation based on Pneumatic Blood Pressure Sensor Data and Synchronous ECG Records
SN - 978-989-758-398-8
AU - Antsiperov V.
AU - Mansurov G.
AU - Bugaev A.
PY - 2020
SP - 301
EP - 307
DO - 10.5220/0009155303010307
PB - SciTePress