SVM Classification of Sparse Set of 1:1 Ventricular and Supraventricular Tachycardia
Mario de-Prado-Cumplido, Ángel Arenal-Maíz, Mercedes Ortiz-Patón, Antonio Artés-Rodríguez
2005
Abstract
Inappropriate classification of Supraventricular Tachycardias with 1:1 atriovetricular conduction is a mayor issue in dual-chamber implantable cardioverter defribillators. In order to distinguish Supraventricular from Ventricular Tachycardias a new methodology is proposed. The tachyarrhythmia episodes ECGs are characterized into feature vectors, which are then classified using a Support Vector Machine. The best features of the vectors are selected by means of several Feature Selection methods. The performance of the algorithm over-comes existing algorithms for implantable devices.
References
- Theuns, D.A., Klootwijk, A., Goedhart, D., Jordaens, L.: Prevention of Inappropriate Therapy in Implantable Cardioverter-Defibrillators Journal of the American College of Cardiology, Vol.44, No.12, (2004)
- Kouakam, C., Kacet, S., Hazard J.R. et al.: Performance of a Dual-chamber Implantable Defibrillator Algorithm for Discrimination of Ventricular from Supraventricular Tachycardia. Europace, 6, (2004), 32-42
- Malik, M., Camm, J., (eds.): Heart Rate Variability. Futura, Nueva York (1995)
- ESC/NASPE Task Force: Heart Rate Variability: Standards of Measurement, Physiological Interpretation and Clinical Use. European Heart Journal, Vol.17, (1996), 354-381
- Schölkopf, B., Smola, A.: Learning with Kernels. MIT Press, Cambridge, MA (2002)
- Rojo- Ílvarez, J.L., Arenal-Maíz, A., Artés-Rodríguez, A.: Discriminating between Supraventricular and Ventricular Tachycardias from EGM Onset Analysis. IEEE Engineering in Medicine and Biology Magazine, Vol.21, No.1, (2002)
- Guyon, I., Weston, J., Barnhill, S., Vapnik, V.: Gene Selection for Cancer Classification Using Support Vector Machines. Machine Learning, Vol.46, No.1-3, (2002)
- Efron, B., Tibshirani, R.: An Introduction to the Bootstrap. Chapman & Hall (1993)
Paper Citation
in Harvard Style
de-Prado-Cumplido M., Arenal-Maíz Á., Ortiz-Patón M. and Artés-Rodríguez A. (2005). SVM Classification of Sparse Set of 1:1 Ventricular and Supraventricular Tachycardia . In Proceedings of the 1st International Workshop on Biosignal Processing and Classification - Volume 1: BPC, (ICINCO 2005) ISBN 972-8865-35-X, pages 95-101. DOI: 10.5220/0001195600950101
in Bibtex Style
@conference{bpc05,
author={Mario de-Prado-Cumplido and Ángel Arenal-Maíz and Mercedes Ortiz-Patón and Antonio Artés-Rodríguez},
title={SVM Classification of Sparse Set of 1:1 Ventricular and Supraventricular Tachycardia},
booktitle={Proceedings of the 1st International Workshop on Biosignal Processing and Classification - Volume 1: BPC, (ICINCO 2005)},
year={2005},
pages={95-101},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001195600950101},
isbn={972-8865-35-X},
}
in EndNote Style
TY - CONF
JO - Proceedings of the 1st International Workshop on Biosignal Processing and Classification - Volume 1: BPC, (ICINCO 2005)
TI - SVM Classification of Sparse Set of 1:1 Ventricular and Supraventricular Tachycardia
SN - 972-8865-35-X
AU - de-Prado-Cumplido M.
AU - Arenal-Maíz Á.
AU - Ortiz-Patón M.
AU - Artés-Rodríguez A.
PY - 2005
SP - 95
EP - 101
DO - 10.5220/0001195600950101