STANDING JUMP LOFT TIME MEASUREMENT - An Acceleration based Method
Susana Palma, Hugo Silva, Hugo Gamboa, Pedro Mil-Homens
2008
Abstract
This paper describes two methods for the measurement of loft time in vertical jumps using signals from an acceleration sensor. The vertical jump accelerometer characteristic curve is presented and notable regions corresponding to key stages of the kinetic activity are identified. Using the accelerometer signals along three dimensions two different algorithms were devised to compute the loft time. These algorithms are based on the morphology of the signal. The first uses the the maximum value of the curve during the landing stage; the second uses the time interval between minimum and maximum values of the acceleration during the flight and landing stages, respectively. To validate these algorithms, a standard algorithm to compute the loft time from force platform signals was employed and these values taken as ground truth. Performance assessment was performed by computing the relative errors between the loft time determined from the force signal and the values obtained with each of the proposed approaches. Preliminary results for a set of 60 jumps let to relative errors of 7.0% for the first method and 2.9% for the second method.
References
- Dowling J., Vamos, L., 1993, J., Identification of Kinetic and Temporal Factors Related to Vertical Jump Performance, Applied Biomechanics, 9.
- Linthorne, N. P., 2001, Analysis of standing vertical jumps using a force platform, Am. Journal of Phys., 69 (11).
- Hassan R., Begg R. K., Khandoker A. H., Stokes R., 2006, Automated Recognition of Human Movement in Stress Situations, Proceedings of the 2nd Internationsl Workshop on Biosignal Procesing and Classification - BPC 2006, INSTICC Press.
- Silva H., Gamboa H., Viegas V., Fred A., 2005, Wireless Physiologic Data Acquisition Platform., 2005. Proceedings of the 5th Conference on Telecomunications Confele.
- Proakis J. G., Manolakis D., 1995, Digital Signal Processing: Principles, Algorithms and Applications, Pearson US Import & PHIPEs, 3rd International Edition.
Paper Citation
in Harvard Style
Palma S., Silva H., Gamboa H. and Mil-Homens P. (2008). STANDING JUMP LOFT TIME MEASUREMENT - An Acceleration based Method . In Proceedings of the First International Conference on Bio-inspired Systems and Signal Processing - Volume 2: BIOSIGNALS, (BIOSTEC 2008) ISBN 978-989-8111-18-0, pages 393-396. DOI: 10.5220/0001069203930396
in Bibtex Style
@conference{biosignals08,
author={Susana Palma and Hugo Silva and Hugo Gamboa and Pedro Mil-Homens},
title={STANDING JUMP LOFT TIME MEASUREMENT - An Acceleration based Method},
booktitle={Proceedings of the First International Conference on Bio-inspired Systems and Signal Processing - Volume 2: BIOSIGNALS, (BIOSTEC 2008)},
year={2008},
pages={393-396},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001069203930396},
isbn={978-989-8111-18-0},
}
in EndNote Style
TY - CONF
JO - Proceedings of the First International Conference on Bio-inspired Systems and Signal Processing - Volume 2: BIOSIGNALS, (BIOSTEC 2008)
TI - STANDING JUMP LOFT TIME MEASUREMENT - An Acceleration based Method
SN - 978-989-8111-18-0
AU - Palma S.
AU - Silva H.
AU - Gamboa H.
AU - Mil-Homens P.
PY - 2008
SP - 393
EP - 396
DO - 10.5220/0001069203930396