This paper describes a digital CMOS Application Specific Integrated Circuit (ASIC) solution with the complete data acquisition and transmission for the use in a wearable electrocardiography (ECG) monitoring system. The main particularity of this system is related to the proposed reconfigurable microchip architecture for an intelligent electrode. The chip area is 2.3 mm2 in a standard 0.18 µm CMOS technology. The chip is operating at 24 MHz system clock with 3.3 V power supply for I/O cells and 1.8 V for the core circuit respectively. The estimated dynamic power dissipation is only 857 µW. The post-layout simulation results show that the microchip embedded inside an intelligent electrode features ultra low power consumption and is quite feasible for a hand-held Personal Health Assistant (PHA) which uses a battery as energy source.
References
- Desel, T., Reichel, T., Rudischhauser, S., Hauer, H., 1996. A CMOS nice channel ECG measurement IC. In 2nd International Conference on ASIC.
- Dong, J., Zhang, S., and Jia, X., 2008. A portable intelligent ECG monitor based on wireless internet and embedded system technology. In International Conference on BioMedical Engineering and Informatics.
- Hung, K., Zhang, Y.T., and Tai, B., 2004. Wearable medical devices for tele-home healthcare. In 26th Ann. International Conf. of the Engineering in Medicine and Biology Society, IEEE-EMBS.
- Lian, Y., and Yu, J., 2005. A low power linear phase digital FIR filter for wearable ECG devices. In 27th Ann. International Conf. of the Engineering in Medicine and Biology Society, IEEE-EMBS.
- Rasid, M. and Woodward, B., 2005. Bluetooth telemedicine processor for multichannel biomedical signal transmission via mo-bile cellular networks. In IEEE Transactions on Information Technology in Biomedicine, vol.9, no.1 pp.35-43.
- Tejero-Calado, J., Lopez-Casado, C., Bernal-Martin, A., Lopez-Gomez, M., Romero-Romero, M., Quesada, G., Lorca, J., and Rivas, R., 2005. IEEE 802.11 ECG monitoring system. In 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS.
- Yang, G., Chen, J., Cao, Y., Hannu, T., and Zheng, L-R., 2008. A Novel Wearable ECG Monitoring System Based on Active-Cable and Intelligent Electrodes. In IEEE Proc of 10th International Conference on eHealth Networking, Applications and Services, Singapore.
Paper Citation
in Harvard Style
Yang G., Chen J., Jonsson F., Tenhunen H. and Zheng L. (2009). AN ASIC SOLUTION FOR INTELLIGENT ELECTRODES AND ACTIVE-CABLE USDED IN A WEARABLE ECG MONITORING SYSTEM . In Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009) ISBN 978-989-8111- 64-7, pages 209-213. DOI: 10.5220/0001539802090213
in Bibtex Style
@conference{biodevices09,
author={Geng Yang and Jian Chen and Fredrik Jonsson and Hannu Tenhunen and Li-Rong Zheng},
title={AN ASIC SOLUTION FOR INTELLIGENT ELECTRODES AND ACTIVE-CABLE USDED IN A WEARABLE ECG MONITORING SYSTEM
},
booktitle={Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)},
year={2009},
pages={209-213},
publisher={SciTePress},
organization={INSTICC},
doi={10.5220/0001539802090213},
isbn={978-989-8111- 64-7},
}
in EndNote Style
TY - CONF
JO - Proceedings of the International Conference on Biomedical Electronics and Devices - Volume 1: BIODEVICES, (BIOSTEC 2009)
TI - AN ASIC SOLUTION FOR INTELLIGENT ELECTRODES AND ACTIVE-CABLE USDED IN A WEARABLE ECG MONITORING SYSTEM
SN - 978-989-8111- 64-7
AU - Yang G.
AU - Chen J.
AU - Jonsson F.
AU - Tenhunen H.
AU - Zheng L.
PY - 2009
SP - 209
EP - 213
DO - 10.5220/0001539802090213